期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Comparison of corneal curvature parameters obtained from two different instruments—Pentacam and VX120 被引量:2
1
作者 Qing-Wei Zhang Chang-Bin Zhai Dong-Li Ma 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第8期1311-1316,共6页
AIM: To explore whether the same corneal curvature parameters and anterior chamber depth measured by Pentacam and VX120 have a good consistency and can replace each other. METHODS: This study enrolled 140 eyes of 70 p... AIM: To explore whether the same corneal curvature parameters and anterior chamber depth measured by Pentacam and VX120 have a good consistency and can replace each other. METHODS: This study enrolled 140 eyes of 70 patients ranging in age from 19 to 53 y. All eyes underwent a comprehensive ophthalmologic examination including an anterior segment analysis with the VX120 system(Visionix-Luneau Technologies, Chartres, France) and Pentacam(Oculus Optikgerate GmbH) respectively. The comparison on corneal curvature parameters was done between Pentacam and VX120 using clustered signed rank test;the interclass correlation coefficients(ICC) with 95% confidence intervals(CI) was calculated for each parameter between Pentacam and VX120;the BlandAltman plot of each parameter was supplemented. RESULTS: The anterior corneal curvature measured by VX120 was Ks: 44.00±1.78 D, KsAt: 89.45±22.18, Kf: 42.84±1.58 D, KfAt: 93.91±79.34;which measured by Pentacam was Ks: 43.80±1.82 D, KsAt: 91.17±21.40, Kf: 42.61±1.64 D, KfAt: 91.16±78.69. There was statistical difference between Pentacam and VX120 for anterior corneal curvature parameter(P<0.001). The posterior corneal curvature measured by VX120 was Ks:-6.42±1.23 D, KsAt: 91.00±23.45, Kf:-5.85±1.24 D, KfAt: 95.93±79.11;which measured by Pentacam was Ks:-6.44±0.32 D, KsAt: 92.24±11.75, Kf:-6.01±1.05 D, KfAt: 74.43±80.64. There was statistical difference between Pentacam and VX120 for posterior corneal curvature parameters(P<0.001). Anterior chamber depth(ACD) measured by Pentacam and VX120was statistically different. Pentacam and VX120 achievedhigh consistency only on corneal anterior surface, including Ks and Kf. The ICCs were 0.96(95%CI: 0.95, 0.97) and 0.95(95%CI: 0.94, 0.97) respectively. For other corneal surface curvature parameters, all ICCs of between Pentacam and VX120 were below 0.87. Bland-Altman plots indicated oflow consistency of corneal surface curvature parameters measured by Pentacam and VX120. CONCLUSION: The corneal curvature parameters and anterior 展开更多
关键词 CORNEAL CURVATURE ANTERIOR CHAMBER depth PENTACAM VX120 interclass correlation coefficients
下载PDF
20MHz与50MHz超声皮肤成像与测量的比较研究 被引量:7
2
作者 冉梦龙 刘德华 +3 位作者 张婧秋 涂平 杨淑霞 李航 《中华皮肤科杂志》 CAS CSCD 北大核心 2017年第7期482-486,共5页
目的 了解20 MHz和50 MHz两种超声频率下人体不同部位皮肤的成像特点,比较两种频率超声测量皮肤厚度时的信度。方法 招募健康志愿者39名,年龄18 ~ 39岁。采用20 MHz和50 MHz超声对受试者全身20个部位皮肤进行超声成像,由3名医师分别... 目的 了解20 MHz和50 MHz两种超声频率下人体不同部位皮肤的成像特点,比较两种频率超声测量皮肤厚度时的信度。方法 招募健康志愿者39名,年龄18 ~ 39岁。采用20 MHz和50 MHz超声对受试者全身20个部位皮肤进行超声成像,由3名医师分别测量各人体部位表皮与真皮的厚度,分析超声图像,并通过计算组内相关系数判断不同频率超声测量不同部位皮肤厚度时的信度。结果 两种频率超声测量各部位表皮时组内相关系数基本小于或接近0.7,信度不理想;在光滑平坦的人体部位,两种频率超声测量真皮时组内相关系数基本大于0.75,信度较高。20 MHz超声可以充分显示真皮与部分皮下组织,50 MHz超声仅能显示真皮层结构,但对细节成像更清晰。在一些解剖结构复杂且不平整的部位,两种频率超声在成像深浅、细节分辨能力方面各有利弊。结论 20 MHz和50 MHz超声作为无创影像工具能够很好地反映表皮及真皮结构;在人体不同部位,要根据两种频率超声的成像特点进行选择。 展开更多
关键词 超声检查 皮肤结构 皮肤厚度 组内相关系数
原文传递
基于空间位移拉曼光谱的皮肤含水量无创检测
3
作者 袁榕穗 吴植强 +2 位作者 聂荣志 钟文婷 张克勤 《光子学报》 EI CAS CSCD 北大核心 2023年第9期121-129,共9页
基于空间位移拉曼光谱原理,搭建了一套可以实现微小空间位移的装置,确定了最优的空间位移距离为300μm,用于穿透皮肤表层,减少皮肤表面水份、油脂等污染物的干扰,最终采集到皮肤内层的水份拉曼信号。该装置采用拉曼波数在3390 cm^(−1)(... 基于空间位移拉曼光谱原理,搭建了一套可以实现微小空间位移的装置,确定了最优的空间位移距离为300μm,用于穿透皮肤表层,减少皮肤表面水份、油脂等污染物的干扰,最终采集到皮肤内层的水份拉曼信号。该装置采用拉曼波数在3390 cm^(−1)(水拉曼峰)和2935 cm^(−1)(蛋白峰)处的强度之比确定组织中的水-蛋白比例,采用便携式光谱仪使设备便于移动,探头和光谱仪以光纤相连使探头可灵活操作,设计满足临床使用要求。实验中检测了7个人、每人10个共70个不同位置的皮肤光谱,将光谱进行去背景算法处理,然后得到精确的拉曼峰强度。以电学法皮肤水份测试仪测试结果作为对比,以组内相关系数作为一致性分析指标,由单个测量组内相关系数为0.889可以看出,基于空间位移拉曼光谱法的人体活体皮肤含水量检测具有较高可行性。 展开更多
关键词 空间位移拉曼光谱 皮肤含水量 无创检测 一致性分析 组内相关系数
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部