The impact of large-scale grid-connected wind farms of Doubly-fed Induction Generator (DFIG) type on power system transient stability is elaborately discussed in this paper. In accordance with an equivalent generator/...The impact of large-scale grid-connected wind farms of Doubly-fed Induction Generator (DFIG) type on power system transient stability is elaborately discussed in this paper. In accordance with an equivalent generator/converter model, the comprehensive numerical simulations with multiple wind farms of DFIG type involved are carried out to reveal the impact of wind farm on dynamic behavior of existing interconnected power system. Different load models involving nonlinear load model and induction motor model are considered during simulations. Finally, some preliminary conclusions are summarized and discussed.展开更多
Large-scale wind power integration has become the current development trend of the power system. Large-scale wind power integration can change the original structure and characteristics of the system. Thus, it’s nece...Large-scale wind power integration has become the current development trend of the power system. Large-scale wind power integration can change the original structure and characteristics of the system. Thus, it’s necessary to analyse the transient stability of power system which contains wind power, and to study the controlling strategy for improving the transient stability of power system. Based on EEAC, this paper studies the transient stability of the power system which contains wind power system theoretically, proposes the calculation method for accelerating area, decelerating area and margin, and illustrates the impact of wind power integration on the transient stability with power angle curve. Furthermore, this paper studies the modeling and simulation, and the experimental results prove the correctness of the theories.展开更多
文摘The impact of large-scale grid-connected wind farms of Doubly-fed Induction Generator (DFIG) type on power system transient stability is elaborately discussed in this paper. In accordance with an equivalent generator/converter model, the comprehensive numerical simulations with multiple wind farms of DFIG type involved are carried out to reveal the impact of wind farm on dynamic behavior of existing interconnected power system. Different load models involving nonlinear load model and induction motor model are considered during simulations. Finally, some preliminary conclusions are summarized and discussed.
文摘Large-scale wind power integration has become the current development trend of the power system. Large-scale wind power integration can change the original structure and characteristics of the system. Thus, it’s necessary to analyse the transient stability of power system which contains wind power, and to study the controlling strategy for improving the transient stability of power system. Based on EEAC, this paper studies the transient stability of the power system which contains wind power system theoretically, proposes the calculation method for accelerating area, decelerating area and margin, and illustrates the impact of wind power integration on the transient stability with power angle curve. Furthermore, this paper studies the modeling and simulation, and the experimental results prove the correctness of the theories.