Power transformer is one of the most important equipment in the power system.Its operating condition affects the reliability of power supply directly.Therefore,in order to guarantee transformer operation safely and re...Power transformer is one of the most important equipment in the power system.Its operating condition affects the reliability of power supply directly.Therefore,in order to guarantee transformer operation safely and reliably,it is necessary to assess condition of power transformer accurately.Return voltage method based on voltage response measurements is still a new non-intrusive diagnosis method for internal insulation aging of transformer.In this paper the technique and application of return voltage measurement and some results of voltage response measurements of several transformers was introduced.Voltage response measurements were performed on various transformers with different voltage grades,various operating periods,different moisture contents and aging degrees on site.Derived moisture contents from return voltage measurement were compared with the corresponding moisture contents obtained from the analysis of oil samples.Based on on-site experiments and theoretical analysis,the criteria for insulation state of transformer are proposed.Moisture condition of transformer insulation can be determined by using return dominant time constant,and a good correlation between aging degree and the return voltage initial slopes of the aged transformers.Field test performed on several transformers,its interpretation of results are also presented,which proves that return voltage measurements can be used as a reliable tool for evaluating moisture content in transformer insulation.展开更多
One of the common characteristics of the electrothermal breakdown in an underwater discharge acoustic source(UDAS) is the existence of a pre-breakdown-heating phase.In our experiment,two phenomena were observed:(1...One of the common characteristics of the electrothermal breakdown in an underwater discharge acoustic source(UDAS) is the existence of a pre-breakdown-heating phase.In our experiment,two phenomena were observed:(1) the breakdown time that takes on high randomicity and obeys a "double-peak" stochastic distribution;(2) the higher salt concentration that reduces the residual voltage and causes 100% non-breakdown.The mechanism of electrothermal breakdown is analysed.To specify the end of the pre-breakdown-heating phase,a "border boiling" assumption is proposed,in which the breakdown time is assumed to be the time needed to heat the border water around the initial arc to 773 K.Based on this 'border boiling' assumption,the numerical simulation is performed to evaluate the effects of two heating mechanisms:the Joule heating from the ionic current,and the radiation heating from the initial arc.The simulation results verify the theoretical explanations to these two experiment phenomena:(1) the stochastic distribution of the radius of the initial arc results in the randomicity of the breakdown time;(2) the difference in efficiency between the radiation heating and the Joule heating determines that,in the case of higher salt concentration,more energy will be consumed in the pre-breakdown-heating phase.展开更多
The initial parameters of the superconducting magnetic energy storage (SMES) fed by a voltage source converter (VSMES) are studied and the setting rules are designed in this paper. A time-domain simulation model is es...The initial parameters of the superconducting magnetic energy storage (SMES) fed by a voltage source converter (VSMES) are studied and the setting rules are designed in this paper. A time-domain simulation model is established by using the software PSCAD/EMTDC. Based on this model, the application of the VSMES in the power system is used to test the designed rules. The simulation results are valuable for the further research of the initial parameters design of the VSMES.展开更多
基金Project Supported by Science and Technology Fund of Fujian E-lectric Power Limited Company(NC2006044)Scientific Research Fund of Fujian Education Depart ment(JB06045)
文摘Power transformer is one of the most important equipment in the power system.Its operating condition affects the reliability of power supply directly.Therefore,in order to guarantee transformer operation safely and reliably,it is necessary to assess condition of power transformer accurately.Return voltage method based on voltage response measurements is still a new non-intrusive diagnosis method for internal insulation aging of transformer.In this paper the technique and application of return voltage measurement and some results of voltage response measurements of several transformers was introduced.Voltage response measurements were performed on various transformers with different voltage grades,various operating periods,different moisture contents and aging degrees on site.Derived moisture contents from return voltage measurement were compared with the corresponding moisture contents obtained from the analysis of oil samples.Based on on-site experiments and theoretical analysis,the criteria for insulation state of transformer are proposed.Moisture condition of transformer insulation can be determined by using return dominant time constant,and a good correlation between aging degree and the return voltage initial slopes of the aged transformers.Field test performed on several transformers,its interpretation of results are also presented,which proves that return voltage measurements can be used as a reliable tool for evaluating moisture content in transformer insulation.
文摘One of the common characteristics of the electrothermal breakdown in an underwater discharge acoustic source(UDAS) is the existence of a pre-breakdown-heating phase.In our experiment,two phenomena were observed:(1) the breakdown time that takes on high randomicity and obeys a "double-peak" stochastic distribution;(2) the higher salt concentration that reduces the residual voltage and causes 100% non-breakdown.The mechanism of electrothermal breakdown is analysed.To specify the end of the pre-breakdown-heating phase,a "border boiling" assumption is proposed,in which the breakdown time is assumed to be the time needed to heat the border water around the initial arc to 773 K.Based on this 'border boiling' assumption,the numerical simulation is performed to evaluate the effects of two heating mechanisms:the Joule heating from the ionic current,and the radiation heating from the initial arc.The simulation results verify the theoretical explanations to these two experiment phenomena:(1) the stochastic distribution of the radius of the initial arc results in the randomicity of the breakdown time;(2) the difference in efficiency between the radiation heating and the Joule heating determines that,in the case of higher salt concentration,more energy will be consumed in the pre-breakdown-heating phase.
文摘The initial parameters of the superconducting magnetic energy storage (SMES) fed by a voltage source converter (VSMES) are studied and the setting rules are designed in this paper. A time-domain simulation model is established by using the software PSCAD/EMTDC. Based on this model, the application of the VSMES in the power system is used to test the designed rules. The simulation results are valuable for the further research of the initial parameters design of the VSMES.