期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
吸气模式对吸入粉雾剂模型体外沉积性能的影响
1
作者 吴飞 陈岚 陈东浩 《中国医药工业杂志》 CAS CSCD 北大核心 2023年第10期1467-1474,共8页
研究了吸气峰值流速和吸气加速度对3种含不同比例细粉乳糖的吸入粉雾剂(DPI)模型体外沉积性能的影响。将布地奈德与乳糖载体和细粉乳糖混合,制得3种处方模型(处方A的细粉乳糖比例为10%,处方B为5%,处方C不含细粉乳糖)。采用阿尔伯塔理想... 研究了吸气峰值流速和吸气加速度对3种含不同比例细粉乳糖的吸入粉雾剂(DPI)模型体外沉积性能的影响。将布地奈德与乳糖载体和细粉乳糖混合,制得3种处方模型(处方A的细粉乳糖比例为10%,处方B为5%,处方C不含细粉乳糖)。采用阿尔伯塔理想化口喉模型和新一代撞击器系统来评价DPI模型的沉积性能。在30、60和90 L/min的吸气峰值流速下进行测试,并使用了2个分别代表“快速”和“慢速”的吸气加速度条件。结果显示,处方A和B的总肺部沉积量都显示出对吸气峰值流速的依赖性(P<0.05);处方C的总肺部沉积量虽不受吸气峰值流速的影响,但受到吸气加速度的影响程度最大。此外,3种处方在“快速”吸气加速度下的小气道沉积量均显著高于在“慢速”吸气加速度下的结果(P<0.05)。由此可见,除了吸气峰值流速之外,吸气加速度也是影响DPI体外性能的重要因素。在本研究范围内,细粉乳糖比例升高可改善处方沉积性能,且受到吸气加速度影响的敏感性降低,但会更依赖于吸气峰值流速。 展开更多
关键词 吸入粉雾剂 布地奈德 细粉乳糖 吸气模式 阿尔伯塔理想化口喉模型 体外评价
原文传递
Particle Deposition in Oral-tracheal Airway Models with Very Low Inhalation Profiles
2
作者 Zheng Li 《Journal of Bionic Engineering》 SCIE EI CSCD 2012年第2期252-261,共10页
Considerable progress has been made on modeling particle deposition in the oral-tracheal airway under some normal breathing conditions, i.e., resting, light activity and moderate exercise. None of these standard breat... Considerable progress has been made on modeling particle deposition in the oral-tracheal airway under some normal breathing conditions, i.e., resting, light activity and moderate exercise. None of these standard breathing patterns correspond to very low inhalation profiles. It is known that particle deposition in the oral-tracheal airway is greatly influenced by flow and particle inlet conditions. In this work, very low inhalation flow rates are considered. Particle deposition is numerically investigated in different oral-tracheal airway models, i.e., circular, elliptic and realistic oral-tracheal airway models. Both micro- and nano-particles that are normally present in cigarette smoke are considered. Results show that inhalation profiles greatly influence the particle deposition. Due to relatively low flow rate, for ultra-fine particles, the oral deposition is enhanced due to longer residence time in oral cavity and stronger Brownian motion. However, for larger particles, less particles deposit in the oral-tracheal airway due to the weaker impaction. The transition happens when particle size changes from 0.01 μm to 0.1 μm. The influence of the limited entrance area is shown and discussed. Under the low inhalation profiles, the highest deposition fraction could be in either circular or realistic models depending on the particle property and the geometric characteristic of oral cavity. The knowledge obtained in this study may be beneficial for the design of bionic inhaler and understanding of health effect from smoke particle on human being. 展开更多
关键词 particle deposition AIRWAY AIRFLOW CFD low inhalation profile
原文传递
巷旁充填设备的研制 被引量:1
3
作者 徐桂云 郑义新 陈淑莲 《煤矿机械》 2000年第2期27-28,共2页
研制一种巷旁充填设备 ,它能够输送颗粒直径小于 5mm的浆液 ,而且体积小 ,换向可靠 ,使用方便 ,很好地满足了充填要求。
关键词 吸排浆球阀 渐开线廊形 拆装端盖 巷旁充填设备
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部