The integrated linkage control problem based on attack detection is solved with the analyses of the security model including firewall, intrusion detection system (IDS) and vulnerability scan by game theory. The Nash...The integrated linkage control problem based on attack detection is solved with the analyses of the security model including firewall, intrusion detection system (IDS) and vulnerability scan by game theory. The Nash equilibrium for two portfolios of only deploying IDS and vulnerability scan and deploying all the technologies is investigated by backward induction. The results show that when the detection rates of IDS and vulnerability scan are low, the firm will not only inspect every user who raises an alarm, but also a fraction of users that do not raise an alarm; when the detection rates of IDS and vulnerability scan are sufficiently high, the firm will not inspect any user who does not raise an alarm, but only inspect a fraction of users that raise an alarm. Adding firewall into the information system impacts on the benefits of firms and hackers, but does not change the optimal strategies of hackers, and the optimal investigation strategies of IDS are only changed in certain cases. Moreover, the interactions between IDS & vulnerability scan and firewall & IDS are discussed in detail.展开更多
Water leakage in drinking water distribution systems is a serious problem for many cities and a huge challenge for water utilities.An integrated system for the detection,early warning,and control of pipeline leakage h...Water leakage in drinking water distribution systems is a serious problem for many cities and a huge challenge for water utilities.An integrated system for the detection,early warning,and control of pipeline leakage has been developed and successfully used to manage the pipeline networks in selected areas of Beijing.A method based on the geographic information system has been proposed to quickly and automatically optimize the layout of the instruments which detect leaks.Methods are also proposed to estimate the probability of each pipe segment leaking (on the basis of historic leakage data),and to assist in locating the leakage points (based on leakage signals).The district metering area (DMA) strategy is used.Guidelines and a flowchart for establishing a DMA to manage the large-scale looped networks in Beijing are proposed.These different functions have been implemented into a central software system to simplify the day-to-day use of the system.In 2007 the system detected 102 non-obvious leakages (i.e.,14.2% of the total detected in Beijing) in the selected areas,which was estimated to save a total volume of 2,385,000 m 3 of water.These results indicate the feasibility,efficiency and wider applicability of this system.展开更多
基金The National Natural Science Foundation of China(No.71071033)the Innovation Project of Jiangsu Postgraduate Education(No.CX10B_058Z)
文摘The integrated linkage control problem based on attack detection is solved with the analyses of the security model including firewall, intrusion detection system (IDS) and vulnerability scan by game theory. The Nash equilibrium for two portfolios of only deploying IDS and vulnerability scan and deploying all the technologies is investigated by backward induction. The results show that when the detection rates of IDS and vulnerability scan are low, the firm will not only inspect every user who raises an alarm, but also a fraction of users that do not raise an alarm; when the detection rates of IDS and vulnerability scan are sufficiently high, the firm will not inspect any user who does not raise an alarm, but only inspect a fraction of users that raise an alarm. Adding firewall into the information system impacts on the benefits of firms and hackers, but does not change the optimal strategies of hackers, and the optimal investigation strategies of IDS are only changed in certain cases. Moreover, the interactions between IDS & vulnerability scan and firewall & IDS are discussed in detail.
基金supported by the National Eleventh-Five Year Research Program of China(No.2006BAB17B03)
文摘Water leakage in drinking water distribution systems is a serious problem for many cities and a huge challenge for water utilities.An integrated system for the detection,early warning,and control of pipeline leakage has been developed and successfully used to manage the pipeline networks in selected areas of Beijing.A method based on the geographic information system has been proposed to quickly and automatically optimize the layout of the instruments which detect leaks.Methods are also proposed to estimate the probability of each pipe segment leaking (on the basis of historic leakage data),and to assist in locating the leakage points (based on leakage signals).The district metering area (DMA) strategy is used.Guidelines and a flowchart for establishing a DMA to manage the large-scale looped networks in Beijing are proposed.These different functions have been implemented into a central software system to simplify the day-to-day use of the system.In 2007 the system detected 102 non-obvious leakages (i.e.,14.2% of the total detected in Beijing) in the selected areas,which was estimated to save a total volume of 2,385,000 m 3 of water.These results indicate the feasibility,efficiency and wider applicability of this system.