Traditional condensing air-conditioning systems consume large amounts of energy in hot and humid areas,and it is difficult to achieve simultaneous control of temperature and humidity.A combined absorption refrigeratio...Traditional condensing air-conditioning systems consume large amounts of energy in hot and humid areas,and it is difficult to achieve simultaneous control of temperature and humidity.A combined absorption refrigeration(AR)and liquid desiccant dehumidification(LDD)air-conditioning system based on cascade utilization of low-grade heat source is proposed.The system can realize independent control of temperature and humidity and carry out profound recovery of low-grade heat sources.Under the design conditions,the heat utilization rate C reaches 21.05%,which is 2.73 times that of the conventional absorption refrigeration reference system.A parametric sensitivity analysis is performed to optimize the system.The C increases from 9.79%to 18.55%and the coefficient of performance C O P t increases from 0.33 to 0.35 with an increase in chilled water temperature from 7°C to 15°C.With an increase in regenerant solution temperature from 60°C to 70°C,the C achieves the optimal value of 21.05%at 68°C.C decreases from 21.05%to 15.05%as the concentration of the regenerant solution increases from 36%to 40%.Under variable environmental temperature and humidity,the C the proposed system changes within a small range and stays much higher than that of the reference system with the same quality heat source,which indicates that the proposed system has a better adaptability to changing environmental parameters.展开更多
Toward solving the actual operation problems of cascade hydropower stations under hydrologic uncertainty, this paper presents the process of extraction of statistical characteristics from long-term optimal cascade ope...Toward solving the actual operation problems of cascade hydropower stations under hydrologic uncertainty, this paper presents the process of extraction of statistical characteristics from long-term optimal cascade operation, and proposes a monthly operation function algorithm for the actual operation of cascade hydropower stations through the identification, processing, and screening of available information during long-term optimal operation. Applying the operation function to the cascade hydropower stations on the Jinshajiang-Yangtze River system, the modeled long-term electric generation is shown to have high precision and provide benefits. Through comparison with optimal operation, the simulation results show that the operation function proposed retains the characteristics of optimal operation. Also, the inadequacies and attribution of the algorithm are discussed based on case study, providing decision support and reference information for research on large-scale cascade operation work.展开更多
基金The authors express gratitude for the support of the National Key Research and Development Program of China(No.2018YFB0905103)the National Natural Science Foundation of China(No.51806213)Beijing Key Laboratory of Distributed Combined Cooling Heating and Power System.
文摘Traditional condensing air-conditioning systems consume large amounts of energy in hot and humid areas,and it is difficult to achieve simultaneous control of temperature and humidity.A combined absorption refrigeration(AR)and liquid desiccant dehumidification(LDD)air-conditioning system based on cascade utilization of low-grade heat source is proposed.The system can realize independent control of temperature and humidity and carry out profound recovery of low-grade heat sources.Under the design conditions,the heat utilization rate C reaches 21.05%,which is 2.73 times that of the conventional absorption refrigeration reference system.A parametric sensitivity analysis is performed to optimize the system.The C increases from 9.79%to 18.55%and the coefficient of performance C O P t increases from 0.33 to 0.35 with an increase in chilled water temperature from 7°C to 15°C.With an increase in regenerant solution temperature from 60°C to 70°C,the C achieves the optimal value of 21.05%at 68°C.C decreases from 21.05%to 15.05%as the concentration of the regenerant solution increases from 36%to 40%.Under variable environmental temperature and humidity,the C the proposed system changes within a small range and stays much higher than that of the reference system with the same quality heat source,which indicates that the proposed system has a better adaptability to changing environmental parameters.
基金supported by the National Natural Science Foundation of China (Grant No. 40971300)the Fundamental Research Funds for the Central Universities (Grant No.10QX43)
文摘Toward solving the actual operation problems of cascade hydropower stations under hydrologic uncertainty, this paper presents the process of extraction of statistical characteristics from long-term optimal cascade operation, and proposes a monthly operation function algorithm for the actual operation of cascade hydropower stations through the identification, processing, and screening of available information during long-term optimal operation. Applying the operation function to the cascade hydropower stations on the Jinshajiang-Yangtze River system, the modeled long-term electric generation is shown to have high precision and provide benefits. Through comparison with optimal operation, the simulation results show that the operation function proposed retains the characteristics of optimal operation. Also, the inadequacies and attribution of the algorithm are discussed based on case study, providing decision support and reference information for research on large-scale cascade operation work.