目的:探讨和比较双源CT和超声心动图对于复杂型先天性心脏病的诊断价值。方法:入选先心病患者47例,均使用SOMA TOM Flash CT扫描仪和超声心动图行心血管检查。所有入选患者均由外科手术或心血管造影证实。比较双源CT与超声心动图的诊断...目的:探讨和比较双源CT和超声心动图对于复杂型先天性心脏病的诊断价值。方法:入选先心病患者47例,均使用SOMA TOM Flash CT扫描仪和超声心动图行心血管检查。所有入选患者均由外科手术或心血管造影证实。比较双源CT与超声心动图的诊断准确率。结果:经手术或心血管造影证实心内结构异常共38处,双源CT诊断34处,诊断准确率89.47%,超声心动图诊断37处,诊断准确率97.37%。两种方法比较无统计学差异;证实心外结构异常69处,双源CT诊断66处,诊断准确率95.65%,超声心电图诊断56处,诊断准确率85.51%,双源CT诊断准确率高于超声心动图(X2=7.07,P=0.008)。结论:双源CT诊断心外结构异常的诊断准确率高于超声心动图,两者结合有利于全面、准确的诊断复杂型先天性心脏病。展开更多
Performance improvement of the high-load transonic turbine is the key method of improving the thrustto-weight ratio or the power density of gas turbine engines. In order to investigate the flow behaviors inside the hi...Performance improvement of the high-load transonic turbine is the key method of improving the thrustto-weight ratio or the power density of gas turbine engines. In order to investigate the flow behaviors inside the high load turbine cascades, a linear turbine cascade test section is designed, which enables the Schlieren photography and static pressure measurement along the cascade profile can be conducted. Variable pitch is realized in the test section to achieve different Zweifel coefficients. Due to the capability limitation of the air supplier, the test section is designed to have only5 blade channels with shortened blade height to achieve high Mach number flow conditions. Numerical investigations were carried out to investigate the wall effect and its in fluences on the flow fields inside the test section. The result indicates that the shape of the connecting part of the test section has a significant influence on the flow similarity among different blade passages. With the proper design, a good repetition flow is achieved between neighbored blade passages.展开更多
Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-...Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-enhanced abdominal and pelvic scans. Methods This institutional review board-approved prospective study included 64 patients who gave written informed consent for additional abdominal and pelvic scan with DSCT in the period from November to December 2012. The patients underwent standard non-enhanced CT scans(protocol 1) [tube voltage of 120 k Vp/pitch of 0.9/filtered back-projection(FBP) reconstruction] followed by high-pitch non-enhanced CT scans(protocol 2)(100 k Vp/3.0/SAFIRE). The total scan time, mean CT number, signal-to-noise ratio(SNR), image quality, lesion detectability and radiation dose were compared between the two protocols. Results The total scan time of protocol 2 was significantly shorter than that of protocol 1(1.4±0.1 seconds vs. 7.6±0.6 seconds, P<0.001). There was no significant difference between protocol 1 and protocol 2 in mean CT number of all organs(liver, 55.4±6.3 HU vs. 56.1±6.8 HU, P=0.214; pancreas, 43.6±5.9 HU vs. 43.7±5.8 HU, P=0.785; spleen, 47.9±3.9 HU vs. 49.4±4.3 HU, P=0.128; kidney, 32.2±2.3 HU vs. 33.1±2.3 HU, P=0.367; abdominal aorta, 44.8±5.6 HU vs. 45.0±5.5 HU, P=0.499; psoas muscle, 50.7±4.1 HU vs. 50.3±4.5 HU, P=0.279). SNR on images of protocol 2 was higher than that of protocol 1(liver, 5.0±1.2 vs. 4.5±1.1, P<0.001; pancreas, 4.0±1.0 vs. 3.6±0.8, P<0.001; spleen, 4.7±1.0 vs. 4.1±0.9, P<0.001; kidney, 3.1±0.6 vs. 2.8±0.6, P<0.001; abdominal aorta, 4.1±1.0 vs. 3.8±1.0, P<0.001; psoas muscle, 4.5±1.1 vs. 4.3±1.2, P=0.012). The overall image noise of protocol 2 was lower than that of protocol1(9.8±3.1 HU vs. 11.1±3.0 HU, P<0.001). Image quality of protocol 2 was good but lower than that of protocol 1(4.1±0.7 vs. 4.6±0.5, P<0.001). Protocol 2 perceived 229 of 234 lesions(97.9%) that were detected in protocol 1 in the abdomen and pe展开更多
文摘目的:探讨和比较双源CT和超声心动图对于复杂型先天性心脏病的诊断价值。方法:入选先心病患者47例,均使用SOMA TOM Flash CT扫描仪和超声心动图行心血管检查。所有入选患者均由外科手术或心血管造影证实。比较双源CT与超声心动图的诊断准确率。结果:经手术或心血管造影证实心内结构异常共38处,双源CT诊断34处,诊断准确率89.47%,超声心动图诊断37处,诊断准确率97.37%。两种方法比较无统计学差异;证实心外结构异常69处,双源CT诊断66处,诊断准确率95.65%,超声心电图诊断56处,诊断准确率85.51%,双源CT诊断准确率高于超声心动图(X2=7.07,P=0.008)。结论:双源CT诊断心外结构异常的诊断准确率高于超声心动图,两者结合有利于全面、准确的诊断复杂型先天性心脏病。
文摘Performance improvement of the high-load transonic turbine is the key method of improving the thrustto-weight ratio or the power density of gas turbine engines. In order to investigate the flow behaviors inside the high load turbine cascades, a linear turbine cascade test section is designed, which enables the Schlieren photography and static pressure measurement along the cascade profile can be conducted. Variable pitch is realized in the test section to achieve different Zweifel coefficients. Due to the capability limitation of the air supplier, the test section is designed to have only5 blade channels with shortened blade height to achieve high Mach number flow conditions. Numerical investigations were carried out to investigate the wall effect and its in fluences on the flow fields inside the test section. The result indicates that the shape of the connecting part of the test section has a significant influence on the flow similarity among different blade passages. With the proper design, a good repetition flow is achieved between neighbored blade passages.
文摘Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-enhanced abdominal and pelvic scans. Methods This institutional review board-approved prospective study included 64 patients who gave written informed consent for additional abdominal and pelvic scan with DSCT in the period from November to December 2012. The patients underwent standard non-enhanced CT scans(protocol 1) [tube voltage of 120 k Vp/pitch of 0.9/filtered back-projection(FBP) reconstruction] followed by high-pitch non-enhanced CT scans(protocol 2)(100 k Vp/3.0/SAFIRE). The total scan time, mean CT number, signal-to-noise ratio(SNR), image quality, lesion detectability and radiation dose were compared between the two protocols. Results The total scan time of protocol 2 was significantly shorter than that of protocol 1(1.4±0.1 seconds vs. 7.6±0.6 seconds, P<0.001). There was no significant difference between protocol 1 and protocol 2 in mean CT number of all organs(liver, 55.4±6.3 HU vs. 56.1±6.8 HU, P=0.214; pancreas, 43.6±5.9 HU vs. 43.7±5.8 HU, P=0.785; spleen, 47.9±3.9 HU vs. 49.4±4.3 HU, P=0.128; kidney, 32.2±2.3 HU vs. 33.1±2.3 HU, P=0.367; abdominal aorta, 44.8±5.6 HU vs. 45.0±5.5 HU, P=0.499; psoas muscle, 50.7±4.1 HU vs. 50.3±4.5 HU, P=0.279). SNR on images of protocol 2 was higher than that of protocol 1(liver, 5.0±1.2 vs. 4.5±1.1, P<0.001; pancreas, 4.0±1.0 vs. 3.6±0.8, P<0.001; spleen, 4.7±1.0 vs. 4.1±0.9, P<0.001; kidney, 3.1±0.6 vs. 2.8±0.6, P<0.001; abdominal aorta, 4.1±1.0 vs. 3.8±1.0, P<0.001; psoas muscle, 4.5±1.1 vs. 4.3±1.2, P=0.012). The overall image noise of protocol 2 was lower than that of protocol1(9.8±3.1 HU vs. 11.1±3.0 HU, P<0.001). Image quality of protocol 2 was good but lower than that of protocol 1(4.1±0.7 vs. 4.6±0.5, P<0.001). Protocol 2 perceived 229 of 234 lesions(97.9%) that were detected in protocol 1 in the abdomen and pe