BACKGROUND Foreign bodies in the pulmonary circulation have been documented in the literature and are typically caused by interventional procedures.However,reports of pulmonary artery foreign bodies during femoral vei...BACKGROUND Foreign bodies in the pulmonary circulation have been documented in the literature and are typically caused by interventional procedures.However,reports of pulmonary artery foreign bodies during femoral vein puncture are rare,and there is no description of this complication from the guidewire surface flows into the pulmonary artery during a pulse ablation in a patient with atrial fibrillation.CASE SUMMARY We described a case in which a linear foreign body suddenly appeared on fluoroscopy image during pulsed ablation of atrial fibrillation.Multiposition angiography showed that the foreign body was currently lodged in the pulmonary artery but was hemodynamically stable.We then chose to use an interventional approach to remove the foreign body from the pulmonary artery.This foreign body was subsequently confirmed to be from the hydrophilic coating of the guidewire surface.This may be related to the difficulties encountered during the puncture of the femoral vein.This is a rare and serious complication of femoral vein puncture.Therefore,we reported this case in order to avoid a similar situation.CONCLUSION Mismatches between interventional devices from different manufacturers used for femoral venipuncture may result in pulmonary artery foreign bodies.展开更多
BACKGROUND An extra tooth in the normal tooth sequence in any region of the dental arch is regarded as a supernumerary tooth(SNT).Due to the large variation in location and morphology,the extraction of impacted SNTs i...BACKGROUND An extra tooth in the normal tooth sequence in any region of the dental arch is regarded as a supernumerary tooth(SNT).Due to the large variation in location and morphology,the extraction of impacted SNTs is an extensive and complex procedure with high risks of several complications.This report presents a rare case of seven impacted SNTs in the bilateral upper and lower arch that were successfully extracted with the use of digital positioning guide plates.CASE SUMMARY In January 2022,a 21-year-old male was referred to our department with a chief complaint of pain in relation to tooth#36.Clinical examination showed a deep carious lesion with pulpal involvement in tooth#36 and lingual swelling of the bilateral mandibular posterior area.Radiographic examination revealed seven deeply impacted SNTs in the bilateral posterior area and bilateral impacted mandibular third molars.Based on these findings,the patient was diagnosed with bilateral,multiple impacted SNTs and tooth#36 chronic pulpitis.A root canal treatment and an all-ceramic crown restoration for tooth#36 were performed.An individualized digital positioning guide plate was designed by computer-aided design/computer-aided manufacturing technology and cone-beam computed tomography for extraction of the impacted SNTs.During the operation,the digital positioning guide plate allowed rapid positioning and exposure of the SNTs while avoiding adjacent important anatomical structures.At 3-month follow-up,regeneration of bone and soft tissues was visible.CONCLUSION The application of digital positioning guide plates is useful for the individualized and minimalized extraction of impacted supernumerary teeth.展开更多
In this study, the goal is to increase the efficiency of a high-pressure hydraulic turbine. The goal is achieved by numerical flow simulation using CFX-TASCflow. This approach reduces costs and time compared to the ex...In this study, the goal is to increase the efficiency of a high-pressure hydraulic turbine. The goal is achieved by numerical flow simulation using CFX-TASCflow. This approach reduces costs and time compared to the experimental approach and allows for improving the turbine productivity and its design. The analysis of energy losses in the flow part of the turbine Fr500, as well as the analysis of the influence of the opening of the guide vanes on changes in energy losses. The results showed that the greatest losses occur in the guide vane 3.02% based on the two-dimensional model and 2.5% based on the 3D model, which significantly affects the efficiency. The analysis was carried out using programs for calculating fluid flow in two-dimensional and three-dimensional formulations. With the help of the study, the main energy problem is solved—increasing efficiency.展开更多
BACKGROUND Recently,medical three-dimensional printing technology(3DPT)has demonstrated potential benefits for the treatment of cubitus varus deformity(CVD)by improving accuracy of the osteotomy through the use of an ...BACKGROUND Recently,medical three-dimensional printing technology(3DPT)has demonstrated potential benefits for the treatment of cubitus varus deformity(CVD)by improving accuracy of the osteotomy through the use of an osteotomy guide,with or without a patient-mated plate.Here,we present an interesting CVD case,involving a patient who was treated with corrective biplanar chevron osteotomy using an innovative customized osteotomy guide and a newly designed patient-matched monoblock crosslink plate created with 3DPT.CASE SUMMARY A 32-year-old female presented with a significant CVD from childhood injury.A computer simulation was processed using images from computerized tomography scans of both upper extremities.The biplanar chevron osteotomy was designed to create identical anatomy between the mirror image of the contralateral distal humerus and the osteotomized distal humerus.Next,the customized osteotomy guide and patient-matched monoblock crosslink plate were designed and printed.A simulation osteotomy was created for the real-sized bone model,and the operation was performed using the posterior paratricipital approach with k-wire positioning from the customized osteotomy guide as a predrilled hole for screw fixation to achieve immediate control of the reduction after osteotomy.Our method allowed for successful treatment of the CVD case,significantly improving the patient’s radiographic and clinical outcomes,with satisfactory result.CONCLUSION 3DPT-created patient-matched osteotomy guide and instrumentation provides accurate control during CVD correction.展开更多
BACKGROUND Coronary artery perforation is a rare but potentially life-threatening complication of percutaneous coronary intervention(PCI),however if recognized and managed promptly,its adverse consequences can be mini...BACKGROUND Coronary artery perforation is a rare but potentially life-threatening complication of percutaneous coronary intervention(PCI),however if recognized and managed promptly,its adverse consequences can be minimized.Risk factors include the use of advanced PCI technique(such as atherectomy and chronic total occlusion interventions)and treatment of severely calcified lesions.Large vessel perforation is usually treated with implantation of a covered stent,whereas distal and collateral vessel perforations are usually treated with embolization of coils,fat,thrombin,or collagen.We describe a novel and cost-effective method of embolisation using a cut remnant of a used angioplasty balloon that was successful in sealing a distal wire perforation.we advocate this method as a simple method of managing distal vessel perforation.CASE SUMMARY A 73-year-old male with previous coronary Bypass graft operation and recurrent angina on minimal exertion had undergone rotablation and PCI to his dominant left circumflex.At the end of the procedure there was evidence of wire perforation at the distal branch and despite prolonged balloon tamponade there continued to be extravasation and the decision was made to seal this perforation.A cut piece of an angioplasty balloon was used and delivered on the original angioplasty wire to before the perforation area and released which resulted in sealing of the perforation with no unwanted clinical consequences.CONCLUSION The use of a balloon remnant for embolization in coronary perforation presents a simple,efficient and cost-effective method for managing coronary perforations and may be an alternative for achieving hemostasis and preventing poor outcome.Prevention remains the most important part with meticulous attention to the distal wire position,particularly with hydrophilic wires.展开更多
在拓扑优化中,因为设计变量多并且目标函数和约束函数都是设计变量的隐函数,求解难度较大,所以寻找更快更好的求解方法一直都是拓扑优化问题的研究重点。为此,将导重法引入到拓扑优化的求解中,介绍质量约束下求结构最优性能问题和性能...在拓扑优化中,因为设计变量多并且目标函数和约束函数都是设计变量的隐函数,求解难度较大,所以寻找更快更好的求解方法一直都是拓扑优化问题的研究重点。为此,将导重法引入到拓扑优化的求解中,介绍质量约束下求结构最优性能问题和性能约束下求结构最小质量问题的导重法迭代准则,采用密度惩罚(Solid isotropic material with penalization,SIMP)方法建立单工况下求最小柔度和最小质量这两类拓扑优化问题的优化模型,推导出用导重法求解这两类问题的迭代公式并计算了相应的算例,与ANSYS中采用的优化准则法(Optimality criteria,OC)和序列凸规划法(Sequential convex programming,SCP)进行对比分析。通过计算和对比分析显示出用导重法求解拓扑优化问题具有迭代公式简单、适用范围广、收敛速度快、求解效果好的优点。导重法为拓扑优化问题的求解提供了一条新的途径。展开更多
基金Supported by the Natural Science Foundation of Shanxi Province,No.20210302123346Shanxi Provincial Health Commission“Four batch”Science and Technology Innovation Project of Medical Development,No.2021XM45.
文摘BACKGROUND Foreign bodies in the pulmonary circulation have been documented in the literature and are typically caused by interventional procedures.However,reports of pulmonary artery foreign bodies during femoral vein puncture are rare,and there is no description of this complication from the guidewire surface flows into the pulmonary artery during a pulse ablation in a patient with atrial fibrillation.CASE SUMMARY We described a case in which a linear foreign body suddenly appeared on fluoroscopy image during pulsed ablation of atrial fibrillation.Multiposition angiography showed that the foreign body was currently lodged in the pulmonary artery but was hemodynamically stable.We then chose to use an interventional approach to remove the foreign body from the pulmonary artery.This foreign body was subsequently confirmed to be from the hydrophilic coating of the guidewire surface.This may be related to the difficulties encountered during the puncture of the femoral vein.This is a rare and serious complication of femoral vein puncture.Therefore,we reported this case in order to avoid a similar situation.CONCLUSION Mismatches between interventional devices from different manufacturers used for femoral venipuncture may result in pulmonary artery foreign bodies.
基金Supported by National Natural Science Foundation of China,No.81970972Applied Basic Research Projects of the 920th Hospital of Joint Logistics Support Force,No.2020YGB06。
文摘BACKGROUND An extra tooth in the normal tooth sequence in any region of the dental arch is regarded as a supernumerary tooth(SNT).Due to the large variation in location and morphology,the extraction of impacted SNTs is an extensive and complex procedure with high risks of several complications.This report presents a rare case of seven impacted SNTs in the bilateral upper and lower arch that were successfully extracted with the use of digital positioning guide plates.CASE SUMMARY In January 2022,a 21-year-old male was referred to our department with a chief complaint of pain in relation to tooth#36.Clinical examination showed a deep carious lesion with pulpal involvement in tooth#36 and lingual swelling of the bilateral mandibular posterior area.Radiographic examination revealed seven deeply impacted SNTs in the bilateral posterior area and bilateral impacted mandibular third molars.Based on these findings,the patient was diagnosed with bilateral,multiple impacted SNTs and tooth#36 chronic pulpitis.A root canal treatment and an all-ceramic crown restoration for tooth#36 were performed.An individualized digital positioning guide plate was designed by computer-aided design/computer-aided manufacturing technology and cone-beam computed tomography for extraction of the impacted SNTs.During the operation,the digital positioning guide plate allowed rapid positioning and exposure of the SNTs while avoiding adjacent important anatomical structures.At 3-month follow-up,regeneration of bone and soft tissues was visible.CONCLUSION The application of digital positioning guide plates is useful for the individualized and minimalized extraction of impacted supernumerary teeth.
文摘In this study, the goal is to increase the efficiency of a high-pressure hydraulic turbine. The goal is achieved by numerical flow simulation using CFX-TASCflow. This approach reduces costs and time compared to the experimental approach and allows for improving the turbine productivity and its design. The analysis of energy losses in the flow part of the turbine Fr500, as well as the analysis of the influence of the opening of the guide vanes on changes in energy losses. The results showed that the greatest losses occur in the guide vane 3.02% based on the two-dimensional model and 2.5% based on the 3D model, which significantly affects the efficiency. The analysis was carried out using programs for calculating fluid flow in two-dimensional and three-dimensional formulations. With the help of the study, the main energy problem is solved—increasing efficiency.
文摘BACKGROUND Recently,medical three-dimensional printing technology(3DPT)has demonstrated potential benefits for the treatment of cubitus varus deformity(CVD)by improving accuracy of the osteotomy through the use of an osteotomy guide,with or without a patient-mated plate.Here,we present an interesting CVD case,involving a patient who was treated with corrective biplanar chevron osteotomy using an innovative customized osteotomy guide and a newly designed patient-matched monoblock crosslink plate created with 3DPT.CASE SUMMARY A 32-year-old female presented with a significant CVD from childhood injury.A computer simulation was processed using images from computerized tomography scans of both upper extremities.The biplanar chevron osteotomy was designed to create identical anatomy between the mirror image of the contralateral distal humerus and the osteotomized distal humerus.Next,the customized osteotomy guide and patient-matched monoblock crosslink plate were designed and printed.A simulation osteotomy was created for the real-sized bone model,and the operation was performed using the posterior paratricipital approach with k-wire positioning from the customized osteotomy guide as a predrilled hole for screw fixation to achieve immediate control of the reduction after osteotomy.Our method allowed for successful treatment of the CVD case,significantly improving the patient’s radiographic and clinical outcomes,with satisfactory result.CONCLUSION 3DPT-created patient-matched osteotomy guide and instrumentation provides accurate control during CVD correction.
文摘BACKGROUND Coronary artery perforation is a rare but potentially life-threatening complication of percutaneous coronary intervention(PCI),however if recognized and managed promptly,its adverse consequences can be minimized.Risk factors include the use of advanced PCI technique(such as atherectomy and chronic total occlusion interventions)and treatment of severely calcified lesions.Large vessel perforation is usually treated with implantation of a covered stent,whereas distal and collateral vessel perforations are usually treated with embolization of coils,fat,thrombin,or collagen.We describe a novel and cost-effective method of embolisation using a cut remnant of a used angioplasty balloon that was successful in sealing a distal wire perforation.we advocate this method as a simple method of managing distal vessel perforation.CASE SUMMARY A 73-year-old male with previous coronary Bypass graft operation and recurrent angina on minimal exertion had undergone rotablation and PCI to his dominant left circumflex.At the end of the procedure there was evidence of wire perforation at the distal branch and despite prolonged balloon tamponade there continued to be extravasation and the decision was made to seal this perforation.A cut piece of an angioplasty balloon was used and delivered on the original angioplasty wire to before the perforation area and released which resulted in sealing of the perforation with no unwanted clinical consequences.CONCLUSION The use of a balloon remnant for embolization in coronary perforation presents a simple,efficient and cost-effective method for managing coronary perforations and may be an alternative for achieving hemostasis and preventing poor outcome.Prevention remains the most important part with meticulous attention to the distal wire position,particularly with hydrophilic wires.
文摘在拓扑优化中,因为设计变量多并且目标函数和约束函数都是设计变量的隐函数,求解难度较大,所以寻找更快更好的求解方法一直都是拓扑优化问题的研究重点。为此,将导重法引入到拓扑优化的求解中,介绍质量约束下求结构最优性能问题和性能约束下求结构最小质量问题的导重法迭代准则,采用密度惩罚(Solid isotropic material with penalization,SIMP)方法建立单工况下求最小柔度和最小质量这两类拓扑优化问题的优化模型,推导出用导重法求解这两类问题的迭代公式并计算了相应的算例,与ANSYS中采用的优化准则法(Optimality criteria,OC)和序列凸规划法(Sequential convex programming,SCP)进行对比分析。通过计算和对比分析显示出用导重法求解拓扑优化问题具有迭代公式简单、适用范围广、收敛速度快、求解效果好的优点。导重法为拓扑优化问题的求解提供了一条新的途径。