Two sample preparation methods were introduced and compared in this paper to establish a simple,quick and exact analysis of geosmin and 2-methylisoborneol.LC-18 column was employed in solid phase extraction(SPE),1.0 m...Two sample preparation methods were introduced and compared in this paper to establish a simple,quick and exact analysis of geosmin and 2-methylisoborneol.LC-18 column was employed in solid phase extraction(SPE),1.0 mL of hexane was adopted in liquid-liquid extraction(LLE),and the extracts were analyzed by gas chromatograph mass spectrum(GCMS)in selected ion mode.Mean recoveries of SPE were low for 2-methylisoborneol(2-MIB)and geosmin(GSM)with values below 50%.For LLE,the recoveries were satisfyingly above 50%for 2-MIB and 80%for GSM.Detection limits of the LLE method were as low as 1.0 ng/L for GSM and 5.0 ng/L for 2-MIB.A year-long investigation on odor chemicals of drinking water in Shanghai demonstrated that in the summer,there was a serious odor problem induced by a high concentration of 2-MIB.The highest concentration of 152.82 ng/L appeared in July in raw water,while GSM flocculation was minimal with concentrations below odor threshold.展开更多
基金This study was supported by the National High-Tech Research and Development(863)Program of China(Grant No.2002AA601130)the Key Technologies Research and Development Program(No.2003BA808A17)of China.
文摘Two sample preparation methods were introduced and compared in this paper to establish a simple,quick and exact analysis of geosmin and 2-methylisoborneol.LC-18 column was employed in solid phase extraction(SPE),1.0 mL of hexane was adopted in liquid-liquid extraction(LLE),and the extracts were analyzed by gas chromatograph mass spectrum(GCMS)in selected ion mode.Mean recoveries of SPE were low for 2-methylisoborneol(2-MIB)and geosmin(GSM)with values below 50%.For LLE,the recoveries were satisfyingly above 50%for 2-MIB and 80%for GSM.Detection limits of the LLE method were as low as 1.0 ng/L for GSM and 5.0 ng/L for 2-MIB.A year-long investigation on odor chemicals of drinking water in Shanghai demonstrated that in the summer,there was a serious odor problem induced by a high concentration of 2-MIB.The highest concentration of 152.82 ng/L appeared in July in raw water,while GSM flocculation was minimal with concentrations below odor threshold.