The capability of ADRC is studied for linear time-invariant SISO minimum-phase systems with unknown orders, uncertain relative degrees, and unknown input disturbances. It is proved that ADRC can reject the unknown inp...The capability of ADRC is studied for linear time-invariant SISO minimum-phase systems with unknown orders, uncertain relative degrees, and unknown input disturbances. It is proved that ADRC can reject the unknown input disturbance and guarantee the close-loop stability for the plants with unknown but bounded relative degrees. Meanwhile, some close-loop performances can be achieved. The influence of the sensor noise is also discussed. And it is demonstrated by numerical examples that one ADRC with fixed parameters can be applied to a group of plants of different orders, relative degrees, and parameters.展开更多
针对光柴互补的独立型微网,利用设计的干扰观测器估计的负荷值,提出了新的微网频率优化控制策略。构造干扰观测器估计出微网中不断变化的负荷值,在光伏(photovoltaic,PV)系统采取最大功率跟踪(maximum power point tracking,MPPT)控制...针对光柴互补的独立型微网,利用设计的干扰观测器估计的负荷值,提出了新的微网频率优化控制策略。构造干扰观测器估计出微网中不断变化的负荷值,在光伏(photovoltaic,PV)系统采取最大功率跟踪(maximum power point tracking,MPPT)控制条件下,基于估计的负荷值和微网频率的变化,设计滑模补偿控制器,并将设计的滑模控制器应用到柴油发电系统的有功功率调节中。仿真结果表明,所提出的频率优化控制策略不仅能够保证光伏系统的最大功率输出,提高光伏能源利用率,同时可减小由于负荷变化和光伏输出功率波动引起的较大微网频率偏差,而且利用所设计控制算法调频可以减少储能设备的硬件投入,为微网的大规模建设节约成本。展开更多
This study aimed to elucidate the strength weakening effect of high static pre-stressed rocks subjected to low-frequency disturbances under uniaxial compression.Based on the uniaxial compressive strength(UCS)of granit...This study aimed to elucidate the strength weakening effect of high static pre-stressed rocks subjected to low-frequency disturbances under uniaxial compression.Based on the uniaxial compressive strength(UCS)of granite under static loading,70%,80%,and 90%of UCS were selected as the initial high static pre-stress(σ_(p)),and then the pre-stressed rock specimens were disturbed by sinusoidal stress with amplitudes of 30%,20%,and 10%of UCS under low-frequency frequencies(f)of 1,2,5,and 10 Hz,respectively.The results show that the rockburst failure of pre-stressed granite is caused by low-frequency disturbance,and the failure strength is much lower than UCS.When theσp or f is constant,the specimen strength gradually decreases as the f or σ_(p) increases.The experimental study illustrates the influence mechanism of the strength weakening effect of high static pre-stress rocks under low-frequency dynamic disturbance,that is,high static pre-stress is the premise and leading factor of rock strength weakening,while low-frequency dynamic disturbance induces rock failure and affects the strength weakening degree.展开更多
In this context,a testing system to understand rock fracturing processes induced by different dynamic disturbances under true triaxial compression was developed.The system is mainly composed of a static loading subsys...In this context,a testing system to understand rock fracturing processes induced by different dynamic disturbances under true triaxial compression was developed.The system is mainly composed of a static loading subsystem,a dynamic loading subsystem,a specimen box subsystem,and a data measurement subsystem.The static loading subsystem uses low stiffness loss frame structure technology,which greatly improves the frame stiffness in the three principal stress directions(up to 20 GN/m)and ensures the demand of the disturbance experiment in both the prepeak and postpeak stages.The disturbance loads with frequency of 0e20 Hz and stress level of 0e30 MPa were applied using large flow parallel oil source technology characterized with high heat dissipation efficiency.For the disturbance loads with frequency of 100e500 Hz and stress level of 0e30 MPa,they were realized by using high-frequency and centimeter-per-second-scale low-speed disturbance rod technology.Three rigid self-stabilizing specimen boxes were utilized to provide support for the specimen and deformation sensors,ensuring the stability and accuracy of the data obtained.To verify the performance of the true triaxial test system,disturbance experiments were conducted on granite specimens.The results show that the experimental device satisfies the requirements of original design,with an excellent repeatability and reliable testing results.展开更多
Wide-area monitoring systems(WAMS)are becoming increasingly vital for enhancing power grid operators’situational awareness capabilities.As a pilot WAMS that was initially deployed in 2003,the frequency monitoring net...Wide-area monitoring systems(WAMS)are becoming increasingly vital for enhancing power grid operators’situational awareness capabilities.As a pilot WAMS that was initially deployed in 2003,the frequency monitoring network FNET/GridEye uses GPS-time-synchronized monitors called frequency disturbance recorders(FDRs)to capture dynamic grid behaviors.Over the past ten years,a large number of publications related to FNET/GridEye have been reported.In this paper,the most recent developments of FNET/GridEye sensors,data centers,and data analytics applications are reviewed.These works demonstrate that FNET/GridEye will become a costeffective situational awareness tool for the future smart grid.展开更多
With the global consciousness of climate change, renewable energy systems are prioritized over the conventional energy systems. The deep injection of renewables into the power systems is creating several challenges to...With the global consciousness of climate change, renewable energy systems are prioritized over the conventional energy systems. The deep injection of renewables into the power systems is creating several challenges to the grid due to wide variations in their output power depending on the time of the day, weather etc. Of these challenges, frequency change plays a vital role in maintaining the power quality. This paper presents a novel sliding mode controller with non-linear disturbance observer to effectively mitigate the wide changes in the frequency. A sliding mode surface based on estimated disturbance along with states is designed. A sliding mode control law is proposed to compensate disturbances including variations in renewables, load and parameters under mismatched uncertainties. The proposed observer based controller is tested for three area multi-machine power system in MATLAB/Simulink. The simulated results proved to alleviate the frequency variations effectively compared to the conventional controllers.展开更多
Hybrid multi-terminal direct current(MTDC)transmission technology has been a research focus,and primary frequency regulation(FR)improvement in the receiving-end system is one of the problems to be solved.This paper pr...Hybrid multi-terminal direct current(MTDC)transmission technology has been a research focus,and primary frequency regulation(FR)improvement in the receiving-end system is one of the problems to be solved.This paper presents a decentralized primary FR scheme for hybrid MTDC power systems considering multi-source enhancement to help suppress frequency disturbance in the receiving-end systems.All the converters only need local frequency or DC voltage signal input to respond to system disturbance without communication or a control center,i.e.,a decentralized control scheme.The proposed scheme can activate appropriate power sources to assist in FR in various system disturbance severities with fine-designed thresholds,ensuring sufficient utilization of each power source.To better balance FR performance and FR resource participation,an evaluation index is proposed and the parameter optimization problem is further conducted.Finally,the validity of the proposed scheme is verified by simulations in MATLAB/Simulink.展开更多
基金supported by Natural Science Foundation of China under Grant Nos.60821091 and 60736022
文摘The capability of ADRC is studied for linear time-invariant SISO minimum-phase systems with unknown orders, uncertain relative degrees, and unknown input disturbances. It is proved that ADRC can reject the unknown input disturbance and guarantee the close-loop stability for the plants with unknown but bounded relative degrees. Meanwhile, some close-loop performances can be achieved. The influence of the sensor noise is also discussed. And it is demonstrated by numerical examples that one ADRC with fixed parameters can be applied to a group of plants of different orders, relative degrees, and parameters.
文摘针对光柴互补的独立型微网,利用设计的干扰观测器估计的负荷值,提出了新的微网频率优化控制策略。构造干扰观测器估计出微网中不断变化的负荷值,在光伏(photovoltaic,PV)系统采取最大功率跟踪(maximum power point tracking,MPPT)控制条件下,基于估计的负荷值和微网频率的变化,设计滑模补偿控制器,并将设计的滑模控制器应用到柴油发电系统的有功功率调节中。仿真结果表明,所提出的频率优化控制策略不仅能够保证光伏系统的最大功率输出,提高光伏能源利用率,同时可减小由于负荷变化和光伏输出功率波动引起的较大微网频率偏差,而且利用所设计控制算法调频可以减少储能设备的硬件投入,为微网的大规模建设节约成本。
基金financially supported by the National Natural Science Foundation of China (No.42077244)the Open Research Fund of State Key Laboratory of Geomechanics and Geotechnical Engineering,Institute of Rock and Soil Mechanics,Chinese Academy of Sciences (No.Z020005)the Fundamental Research Funds for the Central Universities of Southeast University,China (No.2242021R10080)。
文摘This study aimed to elucidate the strength weakening effect of high static pre-stressed rocks subjected to low-frequency disturbances under uniaxial compression.Based on the uniaxial compressive strength(UCS)of granite under static loading,70%,80%,and 90%of UCS were selected as the initial high static pre-stress(σ_(p)),and then the pre-stressed rock specimens were disturbed by sinusoidal stress with amplitudes of 30%,20%,and 10%of UCS under low-frequency frequencies(f)of 1,2,5,and 10 Hz,respectively.The results show that the rockburst failure of pre-stressed granite is caused by low-frequency disturbance,and the failure strength is much lower than UCS.When theσp or f is constant,the specimen strength gradually decreases as the f or σ_(p) increases.The experimental study illustrates the influence mechanism of the strength weakening effect of high static pre-stress rocks under low-frequency dynamic disturbance,that is,high static pre-stress is the premise and leading factor of rock strength weakening,while low-frequency dynamic disturbance induces rock failure and affects the strength weakening degree.
基金This study was financially supported by the National Natural Science Foundation of China(Grant No.51839003),for which we are grateful.
文摘In this context,a testing system to understand rock fracturing processes induced by different dynamic disturbances under true triaxial compression was developed.The system is mainly composed of a static loading subsystem,a dynamic loading subsystem,a specimen box subsystem,and a data measurement subsystem.The static loading subsystem uses low stiffness loss frame structure technology,which greatly improves the frame stiffness in the three principal stress directions(up to 20 GN/m)and ensures the demand of the disturbance experiment in both the prepeak and postpeak stages.The disturbance loads with frequency of 0e20 Hz and stress level of 0e30 MPa were applied using large flow parallel oil source technology characterized with high heat dissipation efficiency.For the disturbance loads with frequency of 100e500 Hz and stress level of 0e30 MPa,they were realized by using high-frequency and centimeter-per-second-scale low-speed disturbance rod technology.Three rigid self-stabilizing specimen boxes were utilized to provide support for the specimen and deformation sensors,ensuring the stability and accuracy of the data obtained.To verify the performance of the true triaxial test system,disturbance experiments were conducted on granite specimens.The results show that the experimental device satisfies the requirements of original design,with an excellent repeatability and reliable testing results.
基金the Engineering Research Center Shared Facilities supported by the Engineering Research Center Program of the National Science Foundation and DOE under NSF Award Number EEC1041877 and the CURENT Industry Partnership Program.
文摘Wide-area monitoring systems(WAMS)are becoming increasingly vital for enhancing power grid operators’situational awareness capabilities.As a pilot WAMS that was initially deployed in 2003,the frequency monitoring network FNET/GridEye uses GPS-time-synchronized monitors called frequency disturbance recorders(FDRs)to capture dynamic grid behaviors.Over the past ten years,a large number of publications related to FNET/GridEye have been reported.In this paper,the most recent developments of FNET/GridEye sensors,data centers,and data analytics applications are reviewed.These works demonstrate that FNET/GridEye will become a costeffective situational awareness tool for the future smart grid.
文摘With the global consciousness of climate change, renewable energy systems are prioritized over the conventional energy systems. The deep injection of renewables into the power systems is creating several challenges to the grid due to wide variations in their output power depending on the time of the day, weather etc. Of these challenges, frequency change plays a vital role in maintaining the power quality. This paper presents a novel sliding mode controller with non-linear disturbance observer to effectively mitigate the wide changes in the frequency. A sliding mode surface based on estimated disturbance along with states is designed. A sliding mode control law is proposed to compensate disturbances including variations in renewables, load and parameters under mismatched uncertainties. The proposed observer based controller is tested for three area multi-machine power system in MATLAB/Simulink. The simulated results proved to alleviate the frequency variations effectively compared to the conventional controllers.
基金supported by the National Natural Science Foundation of China(No.52077196)the Science and Technology Project of State Grid Zhejiang Electric Power Co.,Ltd.(No.5211JY21N001)。
文摘Hybrid multi-terminal direct current(MTDC)transmission technology has been a research focus,and primary frequency regulation(FR)improvement in the receiving-end system is one of the problems to be solved.This paper presents a decentralized primary FR scheme for hybrid MTDC power systems considering multi-source enhancement to help suppress frequency disturbance in the receiving-end systems.All the converters only need local frequency or DC voltage signal input to respond to system disturbance without communication or a control center,i.e.,a decentralized control scheme.The proposed scheme can activate appropriate power sources to assist in FR in various system disturbance severities with fine-designed thresholds,ensuring sufficient utilization of each power source.To better balance FR performance and FR resource participation,an evaluation index is proposed and the parameter optimization problem is further conducted.Finally,the validity of the proposed scheme is verified by simulations in MATLAB/Simulink.