Coriolis mass flowmeter (CMF) is generally regarded as a linear system when the vibration amplitude of the measuring tube is relatively small, but the spectrum of its output signals still show existence of some multip...Coriolis mass flowmeter (CMF) is generally regarded as a linear system when the vibration amplitude of the measuring tube is relatively small, but the spectrum of its output signals still show existence of some multiple frequency components. Taking into consideration the nonlinear factors and external excitation, the motion equations of the CMF straight measuring tube are estab- lished by properly simplifying the boundary conditions of the measuring tube and integrating the mathematical model of the CMF sen...展开更多
The target type flowmeter based on fiber Bragg gratings (FBGs) is experimentally studied. The relationship between the central wavelength shift of FBG and the flux is derived and the analytic expression is also give...The target type flowmeter based on fiber Bragg gratings (FBGs) is experimentally studied. The relationship between the central wavelength shift of FBG and the flux is derived and the analytic expression is also given. Simulation and preliminary experiments have been carried out, and experimental validation of the water further proves the feasibility of the sensor. The experimental results verify the proposed sensor which can measure flux range from 200 to 1200 cm^3/s. And on this basis, the improvement program is raised.展开更多
基金National High-tech Research and Development Pro-gram (2008AA042207)
文摘Coriolis mass flowmeter (CMF) is generally regarded as a linear system when the vibration amplitude of the measuring tube is relatively small, but the spectrum of its output signals still show existence of some multiple frequency components. Taking into consideration the nonlinear factors and external excitation, the motion equations of the CMF straight measuring tube are estab- lished by properly simplifying the boundary conditions of the measuring tube and integrating the mathematical model of the CMF sen...
基金supported by the National"863"Project of China (No.2006AA06Z210 and 2007AA03Z413)the National Natural Science Foundation of China(No.60654001 and 60727004)and the Major Technological Innovation Program of Xi'an City of China(No.GG06004).
文摘The target type flowmeter based on fiber Bragg gratings (FBGs) is experimentally studied. The relationship between the central wavelength shift of FBG and the flux is derived and the analytic expression is also given. Simulation and preliminary experiments have been carried out, and experimental validation of the water further proves the feasibility of the sensor. The experimental results verify the proposed sensor which can measure flux range from 200 to 1200 cm^3/s. And on this basis, the improvement program is raised.