The optimization of the valve plate transition region is an important way of reducing the noise emission for an axial piston pump. However, the optimized methods through simulation or experiment are actually trial and...The optimization of the valve plate transition region is an important way of reducing the noise emission for an axial piston pump. However, the optimized methods through simulation or experiment are actually trial and error, and they cannot indicate the precise structural parameters of the valve plate transition region. In this study, a new design method for the transition region of valve plate based on the matching of flow area and reduction of transient reverse flow was proposed, and with which a valve plate was designed. Then, the impact of the flow ripple in the discharge line of an axial piston pump and the pressure overshoot and undershoot in the piston chamber on hydraulic and structural noise for axial piston pump is discussed. The noise reduction effect of the axial piston pump with this valve plate was analyzed by adopting a flow characteristic simulation model. Finally, the results showed that the application of this design method could contribute much to the reduction of the flow ripple and elimination of the pressure overshoot and undershoot. As a consequence, the method can be used in the design of a low-noise open circuit axial piston pump.展开更多
An investigation of the characteristics of flowrate transientswithin slug flow was conducted in a large- scale outdoor testingfacility. The test section consisted of a 378 m long, 7.62 cmdiameter stainless steel pipe....An investigation of the characteristics of flowrate transientswithin slug flow was conducted in a large- scale outdoor testingfacility. The test section consisted of a 378 m long, 7.62 cmdiameter stainless steel pipe. Air and water were used as the testfluids. The response to a change of flowrate of either phase or twophases Was measured using a series of pressure transducers anddifferential pressure transducers. An increase or decrease In gasflowrate caused a pressure overshoot above the value at new steadystate or led to a pressure undershoot To form a temporary stratifiedflow.展开更多
基金the National Basic Research Program (973 Program) of China,the Science Fund for Creative Research Groups of the National Natural Science Foundation of China
文摘The optimization of the valve plate transition region is an important way of reducing the noise emission for an axial piston pump. However, the optimized methods through simulation or experiment are actually trial and error, and they cannot indicate the precise structural parameters of the valve plate transition region. In this study, a new design method for the transition region of valve plate based on the matching of flow area and reduction of transient reverse flow was proposed, and with which a valve plate was designed. Then, the impact of the flow ripple in the discharge line of an axial piston pump and the pressure overshoot and undershoot in the piston chamber on hydraulic and structural noise for axial piston pump is discussed. The noise reduction effect of the axial piston pump with this valve plate was analyzed by adopting a flow characteristic simulation model. Finally, the results showed that the application of this design method could contribute much to the reduction of the flow ripple and elimination of the pressure overshoot and undershoot. As a consequence, the method can be used in the design of a low-noise open circuit axial piston pump.
基金Supported by the National Natural Science Foundation of China (No.59995462) and the National Science Foundation of China for distinguished Young Scientists (No. 59725616).
文摘An investigation of the characteristics of flowrate transientswithin slug flow was conducted in a large- scale outdoor testingfacility. The test section consisted of a 378 m long, 7.62 cmdiameter stainless steel pipe. Air and water were used as the testfluids. The response to a change of flowrate of either phase or twophases Was measured using a series of pressure transducers anddifferential pressure transducers. An increase or decrease In gasflowrate caused a pressure overshoot above the value at new steadystate or led to a pressure undershoot To form a temporary stratifiedflow.