Numerical simulation method is applied in the study oftwo - phase flow dynamics in the eliminator of air wash-er. The carrier phase (air) is treated in Eulerian frame,the water droplets are tracked in the Lagrangian f...Numerical simulation method is applied in the study oftwo - phase flow dynamics in the eliminator of air wash-er. The carrier phase (air) is treated in Eulerian frame,the water droplets are tracked in the Lagrangian frame.A three - dimensional unsteady two - phase flow model isdeveloped. With the help of FLUENT software, air-stream velocity field and water droplets trajectories havebeen illustrated when their mixture passing through tra-ditional folded eliminator. The result of the simulationcan be used to investigate the mechanism of展开更多
The aim of this paper is to study the behaviour of bipolar corona with a dual parallel corona bar and a metallic plate. The experimental results show that under otherwise identical conditions, the discharge depends st...The aim of this paper is to study the behaviour of bipolar corona with a dual parallel corona bar and a metallic plate. The experimental results show that under otherwise identical conditions, the discharge depends strongly on the electrode separation between the bars. By investigating various separations, the corona regime can be divided into three regions: independent, shunted, and shorted. The criterion for eliminating electrostatic charge without over compensation is also given.展开更多
Ferroresonance in distribution networks is usually hard to be identified and predicted because it is nonlinear and dependent on multiple factors and conditions.This study discusses different common antiferroresonance...Ferroresonance in distribution networks is usually hard to be identified and predicted because it is nonlinear and dependent on multiple factors and conditions.This study discusses different common antiferroresonance methods by numerical simulations and experimental tests.In order to study the reliability of the anti-ferroresonance measures,a 10 kV ferroresonance testing system was setup.Then a number of simulations and experiments were carried out to show the ferroresonance phenomena initiated by single-phase grounding faults and/or single-phase disconnection faults.In addition,potential transformer models with the characteristic of non-linear magnetic excitation were developed and used in PSCAD-based simulation studies.These studies investigated the performance of primary resonance eliminators and arc suppression coils on restraining the ferroresonance under multiple power system parameters and initialisations.In addition,a joint anti-ferroresonance method is proposed and verified.The simulation and experimental studies can provide guidelines for evaluating the anti-ferroresonance methods in distribution networks.展开更多
Reynolds-averaged Navier-Stokes(RANS)turbulence modeling can lead to the excessive turbulence level around the interface in two-phase flow,which causes the unphysical motion of the interface in sloshing simulation.In ...Reynolds-averaged Navier-Stokes(RANS)turbulence modeling can lead to the excessive turbulence level around the interface in two-phase flow,which causes the unphysical motion of the interface in sloshing simulation.In order to avoid the unphysical motion of the interface,a novel eddy-viscosity eliminator based on sigmoid functions is designed to reduce the excessive turbulence level,and the eddy-viscosity eliminator based on polynomials is extracted from the cavitation simulations.Surface elevations by combining the eddy-viscosity eliminators and classical two-equation closure models are compared with the experiments,the ones by using the adaptive asymptotic model(AAM)and the ones by using the modified two-equation closure models.The root-mean-squared error(RMSE)is introduced to quantify the accuracies of surface elevations and the forces.The relation between the turbulence level in the transition layer and RMSEs of surface elevations is studied.Besides,the parametric analysis of the eddy-viscosity eliminators is carried out.The studies suggest that(1)the excessive turbulence level in the transition layer around the interface has a significant influence on the accuracies of surface elevations and the forces;(2)the eddy-viscosity eliminators can effectively reduce the excessive turbulence level in the transition layer to avoid the unphysical motion of the interface;(3)the k-ωSST model combined with the eddy-viscosity eliminators is appropriate for predicting surface elevations and forces in RANS simulations of sloshing flow.展开更多
As for electrostatic elimination there are many means.But the high humidity air electrostatic eliminator has simple,efficient, lightproof and fireproof etc. advantages. Thus it is often used in some industrial enterpr...As for electrostatic elimination there are many means.But the high humidity air electrostatic eliminator has simple,efficient, lightproof and fireproof etc. advantages. Thus it is often used in some industrial enterprises. The aim of this paper is to introduce an experimental device of high humidity air electrostatic eliminator and its principle and experimental data.展开更多
基金Supported by Development Foundation of Dong Hua Univetsity
文摘Numerical simulation method is applied in the study oftwo - phase flow dynamics in the eliminator of air wash-er. The carrier phase (air) is treated in Eulerian frame,the water droplets are tracked in the Lagrangian frame.A three - dimensional unsteady two - phase flow model isdeveloped. With the help of FLUENT software, air-stream velocity field and water droplets trajectories havebeen illustrated when their mixture passing through tra-ditional folded eliminator. The result of the simulationcan be used to investigate the mechanism of
文摘The aim of this paper is to study the behaviour of bipolar corona with a dual parallel corona bar and a metallic plate. The experimental results show that under otherwise identical conditions, the discharge depends strongly on the electrode separation between the bars. By investigating various separations, the corona regime can be divided into three regions: independent, shunted, and shorted. The criterion for eliminating electrostatic charge without over compensation is also given.
文摘Ferroresonance in distribution networks is usually hard to be identified and predicted because it is nonlinear and dependent on multiple factors and conditions.This study discusses different common antiferroresonance methods by numerical simulations and experimental tests.In order to study the reliability of the anti-ferroresonance measures,a 10 kV ferroresonance testing system was setup.Then a number of simulations and experiments were carried out to show the ferroresonance phenomena initiated by single-phase grounding faults and/or single-phase disconnection faults.In addition,potential transformer models with the characteristic of non-linear magnetic excitation were developed and used in PSCAD-based simulation studies.These studies investigated the performance of primary resonance eliminators and arc suppression coils on restraining the ferroresonance under multiple power system parameters and initialisations.In addition,a joint anti-ferroresonance method is proposed and verified.The simulation and experimental studies can provide guidelines for evaluating the anti-ferroresonance methods in distribution networks.
基金financially supported by the National Natural Science Foundation of China(Grant Nos.11802176,11802301)。
文摘Reynolds-averaged Navier-Stokes(RANS)turbulence modeling can lead to the excessive turbulence level around the interface in two-phase flow,which causes the unphysical motion of the interface in sloshing simulation.In order to avoid the unphysical motion of the interface,a novel eddy-viscosity eliminator based on sigmoid functions is designed to reduce the excessive turbulence level,and the eddy-viscosity eliminator based on polynomials is extracted from the cavitation simulations.Surface elevations by combining the eddy-viscosity eliminators and classical two-equation closure models are compared with the experiments,the ones by using the adaptive asymptotic model(AAM)and the ones by using the modified two-equation closure models.The root-mean-squared error(RMSE)is introduced to quantify the accuracies of surface elevations and the forces.The relation between the turbulence level in the transition layer and RMSEs of surface elevations is studied.Besides,the parametric analysis of the eddy-viscosity eliminators is carried out.The studies suggest that(1)the excessive turbulence level in the transition layer around the interface has a significant influence on the accuracies of surface elevations and the forces;(2)the eddy-viscosity eliminators can effectively reduce the excessive turbulence level in the transition layer to avoid the unphysical motion of the interface;(3)the k-ωSST model combined with the eddy-viscosity eliminators is appropriate for predicting surface elevations and forces in RANS simulations of sloshing flow.
文摘As for electrostatic elimination there are many means.But the high humidity air electrostatic eliminator has simple,efficient, lightproof and fireproof etc. advantages. Thus it is often used in some industrial enterprises. The aim of this paper is to introduce an experimental device of high humidity air electrostatic eliminator and its principle and experimental data.