To identify refl ector fractures near borehole by using dipole-source refl ected-shearwave logging, we need to understand the relation between the amplitude of the refl ected shear wave and the source radiation, boreh...To identify refl ector fractures near borehole by using dipole-source refl ected-shearwave logging, we need to understand the relation between the amplitude of the refl ected shear wave and the source radiation, borehole conditions, and attenuation owing to the surrounding formations. To assess the effect of these factors on the amplitude of the refl ected waves, we first studied the radiation performance and radiation direction of the dipole source in fast, medium, and slow formations by using the asymptotic solution in the far fi eld of the borehole. Then, the relation between the fracture parameters, and the refl ected-shear-wave amplitude as well as the ratio of the refl ected-shear-wave amplitude to the direct-wave amplitude (relative amplitude, RA) was evaluated by the three-dimensional fi nite-difference (3D FDTD) method. Finally, the fracture detection capability of the dipole reflected-shear-wave logging tool in different formations was analyzed by using the RA. The results suggest that the radiation amplitude of the SH-wave in the slow formation is weaker than those in the fast and medium formations, and the amplitude of the refl ected shear wave is lower. However, the RA in the slow formation is close to or even greater than in the fast and medium formations, which means that dipole-source shear-wave logging has the same or even better fracture detection capability in the slow formation as in the fast and medium formations. In addition, when RA is small, there is a good correlation between the RA and the various fracture parameters in the different types of formation, which can be used in determining the lower limit of the fracture parameters identifi ed by refl ection logging.展开更多
In this study, 2.4 mm thick high-strength martensitic steel plates with a tensile strength of 1500 MPa were friction stir welded at various welding speeds of 40, 60, 80, 100, 120 mm/min and a constant rotation speed o...In this study, 2.4 mm thick high-strength martensitic steel plates with a tensile strength of 1500 MPa were friction stir welded at various welding speeds of 40, 60, 80, 100, 120 mm/min and a constant rotation speed of 300 rpm. Sound joints could be obtained when the welding speed was 40, 60 and 80 mm/min, while a kissing bond was found in the joint welded at 100 and 120 mm/min. It was revealed that the peak temperature exceeded A C3(the end temperature at which all ferrite transformed to austenite when the steel was heated) for all the welding conditions and martensitic structures were fi nally formed in the stir zone of the joints. A signifi cant decrease in hardness was located in the heat-aff ected zone, which had a transitional microstructure from tempered martensite near base metal to a mixed structure containing hard martensite, soft ferrite and bainite near stir zone. For the sound joints, the specimen was fractured in the heat-aff ected zone during tensile tests and the highest tensile strength could reach about 1058 MPa.展开更多
This paper sums up the determining analysis of the measuring location of Treflusing a thermocouple during the thermography tests.Laboratory temperature distribution testing methods,analysis of value and location of Tre...This paper sums up the determining analysis of the measuring location of Treflusing a thermocouple during the thermography tests.Laboratory temperature distribution testing methods,analysis of value and location of Treflmeasurement are explained in this paper.The heat source is two halogen lamps of 500 watts eachfitted at a distance of 30–50 cm.Noises appearing during testing of thermography are corrected with measured T_(refl) value.The results of thermogram correction of corroded concrete surfaces using T_(refl) values are displayed in this paper too.The concrete surface temperature results of quantitative image processing method are compared to the experimental test results.The results showed good accuracy,which was seen from most errors<3%and the maximum error is<5%.The end of paper,explained of application Treflvalue to the corroded reinforced concrete thermogram.展开更多
基金supported by the National Petroleum Major Projects(No.2017ZX05019-005)CNPC Fundamental Research Projects(No.2016A-3605)
文摘To identify refl ector fractures near borehole by using dipole-source refl ected-shearwave logging, we need to understand the relation between the amplitude of the refl ected shear wave and the source radiation, borehole conditions, and attenuation owing to the surrounding formations. To assess the effect of these factors on the amplitude of the refl ected waves, we first studied the radiation performance and radiation direction of the dipole source in fast, medium, and slow formations by using the asymptotic solution in the far fi eld of the borehole. Then, the relation between the fracture parameters, and the refl ected-shear-wave amplitude as well as the ratio of the refl ected-shear-wave amplitude to the direct-wave amplitude (relative amplitude, RA) was evaluated by the three-dimensional fi nite-difference (3D FDTD) method. Finally, the fracture detection capability of the dipole reflected-shear-wave logging tool in different formations was analyzed by using the RA. The results suggest that the radiation amplitude of the SH-wave in the slow formation is weaker than those in the fast and medium formations, and the amplitude of the refl ected shear wave is lower. However, the RA in the slow formation is close to or even greater than in the fast and medium formations, which means that dipole-source shear-wave logging has the same or even better fracture detection capability in the slow formation as in the fast and medium formations. In addition, when RA is small, there is a good correlation between the RA and the various fracture parameters in the different types of formation, which can be used in determining the lower limit of the fracture parameters identifi ed by refl ection logging.
基金supported by the Henan provincial Joint Fund of the National Natural Science Foundation of China (Grant No.U2004170)the Natural Science Foundation of Henan Province (No.202300410474)。
文摘In this study, 2.4 mm thick high-strength martensitic steel plates with a tensile strength of 1500 MPa were friction stir welded at various welding speeds of 40, 60, 80, 100, 120 mm/min and a constant rotation speed of 300 rpm. Sound joints could be obtained when the welding speed was 40, 60 and 80 mm/min, while a kissing bond was found in the joint welded at 100 and 120 mm/min. It was revealed that the peak temperature exceeded A C3(the end temperature at which all ferrite transformed to austenite when the steel was heated) for all the welding conditions and martensitic structures were fi nally formed in the stir zone of the joints. A signifi cant decrease in hardness was located in the heat-aff ected zone, which had a transitional microstructure from tempered martensite near base metal to a mixed structure containing hard martensite, soft ferrite and bainite near stir zone. For the sound joints, the specimen was fractured in the heat-aff ected zone during tensile tests and the highest tensile strength could reach about 1058 MPa.
基金This research was supported by the P3MI Research Grants.Thanks to Prof.Herlien D Setio as authors who received the grant.
文摘This paper sums up the determining analysis of the measuring location of Treflusing a thermocouple during the thermography tests.Laboratory temperature distribution testing methods,analysis of value and location of Treflmeasurement are explained in this paper.The heat source is two halogen lamps of 500 watts eachfitted at a distance of 30–50 cm.Noises appearing during testing of thermography are corrected with measured T_(refl) value.The results of thermogram correction of corroded concrete surfaces using T_(refl) values are displayed in this paper too.The concrete surface temperature results of quantitative image processing method are compared to the experimental test results.The results showed good accuracy,which was seen from most errors<3%and the maximum error is<5%.The end of paper,explained of application Treflvalue to the corroded reinforced concrete thermogram.