变水头装置液位开关的不确定度评定方法
1
作者 沈昱明 陆峰 《测控技术》 2021年第8期7-11,共5页
对变水头流量标准装置不确定度评定结果产生影响的液位开关动态响应做了理论分析和实验研究。分别针对电容式和导纳式两种常见液位开关的工作原理,推导建立了其动态响应理论模型,建立了液位开关的传递函数,从理论参数得出:被测电容式和... 对变水头流量标准装置不确定度评定结果产生影响的液位开关动态响应做了理论分析和实验研究。分别针对电容式和导纳式两种常见液位开关的工作原理,推导建立了其动态响应理论模型,建立了液位开关的传递函数,从理论参数得出:被测电容式和导纳式液位开关的动态响应不确定度基本相当,并对变水头装置液位开关的动态响应不确定度评定方法做了讨论。根据所提出的评定方法进行了相关实验,实验结果表明,电容式液位开关的动态响应不确定度可以达到0.034%,且随着液面下降速度增加,其不确定度也有增加的趋势,为变水头流量标准装置的工程实践和不确定度评定提供了理论参考。 展开更多
关键词 流量标准装置 变水头 液位开关 动态响应实验 不确定度评定
下载PDF
WRIST FORCE SENSOR'S DYNAMIC PERFORMANCE CALIBRATION BASED ON NEGATIVE STEP RESPONSE 被引量:2
2
作者 ZHENG Hongmei 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2008年第5期92-96,共5页
Negative step response experimental method is used in wrist force sensor's dynamic performance calibration. The exciting manner of negative step response method is the same as wrist force sensor's load in working. T... Negative step response experimental method is used in wrist force sensor's dynamic performance calibration. The exciting manner of negative step response method is the same as wrist force sensor's load in working. This experimental method needn't special experiment equipments. Experiment's dynamic repeatability is good. So wrist force sensor's dynamic performance is suitable to be calibrated by negative step response method. A new correlation wavelet transfer method is studied. By wavelet transfer method, the signal is decomposed into two dimensional spaces of time-frequency. So the problem of negative step exciting energy concentrating in the low frequency band is solved. Correlation wavelet transfer doesn't require that wavelet primary function be orthogonal and needn't wavelet reconstruction. So analyzing efficiency is high. An experimental bench is designed and manufactured to load the wrist force sensor orthogonal excitation force/moment. A piezoelectric force sensor is used to setup soft trigger and calculate the value of negative step excitation. A wrist force sensor is calibrated. The pulse response function is calculated after negative step excitation and step response have been transformed to positive step excitation and step response. The pulse response function is transferred to frequency response function. The wrist force sensor's dynamic characteristics are identified by the frequency response function. 展开更多
关键词 Wrist force sensor dynamic performance calibration Step response experiment Correlation wavelet transfer Impulse response function
下载PDF
缓冲装置对炸药装药抗过载安定性影响研究 被引量:4
3
作者 许志峰 李亮亮 屈可朋 《科学技术与工程》 北大核心 2015年第18期179-182,共4页
采用大型落锤模拟加载系统研究了缓冲装置对炸药装药抗过载安全性的影响。结果表明,缓冲装置可以对炸药进行有效保护;缓冲装置改变了外部载荷的特征,使得外部载荷不容易使炸药点火,进而提高了炸药的抗过载安全性,为战斗部的装药设计提... 采用大型落锤模拟加载系统研究了缓冲装置对炸药装药抗过载安全性的影响。结果表明,缓冲装置可以对炸药进行有效保护;缓冲装置改变了外部载荷的特征,使得外部载荷不容易使炸药点火,进而提高了炸药的抗过载安全性,为战斗部的装药设计提供依据。 展开更多
关键词 大落锤加载 点火性能 动力学响应 模拟实验 炸药装药