用紫外 -可见吸收光谱、动态光散射与透射电镜研究紫外光辐射对 Ti O2 溶胶的影响 ,结果表明 ,光辐射使 Ti O2 溶胶在可见光区的吸收减少 ,紫外区吸收增加 ,吸收带隙增大 .与非光辐射的 Ti O2 溶胶粒子相比 ,光辐射使 Ti O2 溶胶粒子分...用紫外 -可见吸收光谱、动态光散射与透射电镜研究紫外光辐射对 Ti O2 溶胶的影响 ,结果表明 ,光辐射使 Ti O2 溶胶在可见光区的吸收减少 ,紫外区吸收增加 ,吸收带隙增大 .与非光辐射的 Ti O2 溶胶粒子相比 ,光辐射使 Ti O2 溶胶粒子分布均匀且平均粒径减小 ,提高了 Ti O2展开更多
The complexes formed by the interaction of human serum albumin and ampicillin sodium in aqueous solutions were investigated at 25 ± 0.1℃, ionic strength I = 0.085 mol·kg-1, pH 4.9, 5.8 and 7.4. The results ...The complexes formed by the interaction of human serum albumin and ampicillin sodium in aqueous solutions were investigated at 25 ± 0.1℃, ionic strength I = 0.085 mol·kg-1, pH 4.9, 5.8 and 7.4. The results of static light scattering have suggested that at pH 7.4, 5.8, 4.9, the molecular weight of the protein/drug complexes is 210,000 g·mol-1, 418,000 g·mol-1, 448,000 g·mol-1, re- spectively. The z-average root-mean-square radius of gyration and the second virial coefficients de- crease with pH decreasing. Dynamic light scattering provides information on diffusion coefficient and particle distributions of protein/drug complexes under different conditions, which suggests a broad hydrodynamic diameter range of scatters. The diffusion coefficients of the systems change with am- picillin sodium concentration and pH changing.展开更多
The procedure to measure liposome in aqueous solution has been examined using atomic force microscope (AFM). We concluded a chemical modified silicon wafer (substrate for AFM observation of liposome) with 3-aminopropy...The procedure to measure liposome in aqueous solution has been examined using atomic force microscope (AFM). We concluded a chemical modified silicon wafer (substrate for AFM observation of liposome) with 3-aminopropyltrieth-oxysilane (APTES) which enabled us to scan anionic liposome softly in water because they were keeping structures as vesicles and stably adsorbed on the substrate by electrostatic force. From captured AFM topographic images, we counted the amount of liposome and analyzed the distribution of mean diameters, which were corrected by an approximated curve of the tip shape. We discussed the method of effective evaluation as practical analysis and its problems for robust analysis.展开更多
文摘用紫外 -可见吸收光谱、动态光散射与透射电镜研究紫外光辐射对 Ti O2 溶胶的影响 ,结果表明 ,光辐射使 Ti O2 溶胶在可见光区的吸收减少 ,紫外区吸收增加 ,吸收带隙增大 .与非光辐射的 Ti O2 溶胶粒子相比 ,光辐射使 Ti O2 溶胶粒子分布均匀且平均粒径减小 ,提高了 Ti O2
基金This work was supported by the National Natural Science Foundation of China (Grant No.20275014).
文摘The complexes formed by the interaction of human serum albumin and ampicillin sodium in aqueous solutions were investigated at 25 ± 0.1℃, ionic strength I = 0.085 mol·kg-1, pH 4.9, 5.8 and 7.4. The results of static light scattering have suggested that at pH 7.4, 5.8, 4.9, the molecular weight of the protein/drug complexes is 210,000 g·mol-1, 418,000 g·mol-1, 448,000 g·mol-1, re- spectively. The z-average root-mean-square radius of gyration and the second virial coefficients de- crease with pH decreasing. Dynamic light scattering provides information on diffusion coefficient and particle distributions of protein/drug complexes under different conditions, which suggests a broad hydrodynamic diameter range of scatters. The diffusion coefficients of the systems change with am- picillin sodium concentration and pH changing.
文摘The procedure to measure liposome in aqueous solution has been examined using atomic force microscope (AFM). We concluded a chemical modified silicon wafer (substrate for AFM observation of liposome) with 3-aminopropyltrieth-oxysilane (APTES) which enabled us to scan anionic liposome softly in water because they were keeping structures as vesicles and stably adsorbed on the substrate by electrostatic force. From captured AFM topographic images, we counted the amount of liposome and analyzed the distribution of mean diameters, which were corrected by an approximated curve of the tip shape. We discussed the method of effective evaluation as practical analysis and its problems for robust analysis.