Global seismicity catalogs are sufficient for characterizing double seismic zones (DSZs) in subducting slab and facilitate to estimate layer separation without inconsistent uncertainties as local catalogs. Previous ...Global seismicity catalogs are sufficient for characterizing double seismic zones (DSZs) in subducting slab and facilitate to estimate layer separation without inconsistent uncertainties as local catalogs. Previous studies have shown the correlation between DSZs layer separation and plate age while correlation for those younger than -60 Ma is suspicious. The lacking of DSZs with layer separation less than 10 km further makes it difficult to precisely estimate such correlation. Thus, we incorporate eight DSZs data determined through local seismicity into globally-determined dataset and reexamine such correlation. The best fitting results show that both a linear model and a square root of plate age can mathematically fit the layer separation well. However, it is difficult to distinguish these two models when plate age is greater than -20 Ma since their difference is less than 2 km. However, if extrapolation is possible, both models should provide physical information that DSZs will not form if there is no subducting lithosphere. As a result, the DSZs cannot be produced until the oceanic lithospheric age becomes greater than 0.9 Ma in the square root model while the linear model gives a misleading result. As such the square root model demonstrates the relationship physically better than the linear one, it still needs further test in the future with more available data, nevertheless, our study might also provide evidence for the suggestion that the plate age is a primary control factor of the DSZs geometry as well as the subducting process which disregards any local tectonic stresses.展开更多
Based on the experimental results, in which the fabricated error of the double layer frequency selective surface (FSS) leads to the transmission loss and the resonant frequency leaves away the design resonant frequenc...Based on the experimental results, in which the fabricated error of the double layer frequency selective surface (FSS) leads to the transmission loss and the resonant frequency leaves away the design resonant frequency, the inter-layer separation distance (ISD) and the unit cell aligning error (UAE) were used as main variables to study the transmission performance attenuation of the double layer FSS configuration. The numerical analysis model for ISD and UAE was established and also was used to simulate the ring unit cell FSS transmission performance by the finite element and periodic moment methods. The double layer ring aperture FSS configuration designed was used as the numerical model. As a result of the numerical analysis, it is shown that both ISD and UAE produce insertion transmission loss (ITL) and insertion phase distortion (IPD) directly. Furthermore, ISD results in more loss of the amplitude of the transmitted signal for the FSS than UAE. It is significant for the designer of the multiplayer FSS to assign the fabricated error of the FSS dielectric layers. The UAE introduces the insertion phase variation badly.展开更多
Electric double-layer field effect experiments were performed on ultrathin films of La0.325Pr0.3Ca0.375MnO3, which is noted for its micrometer-scale phase separation. A clear change of resistance up to 220% was observ...Electric double-layer field effect experiments were performed on ultrathin films of La0.325Pr0.3Ca0.375MnO3, which is noted for its micrometer-scale phase separation. A clear change of resistance up to 220% was observed and the characteristic metal-insulator transition temperature Tp was also shifted. The changes of both the resistance and Tp, suggest that the electric field induced not only tuning of the carrier density but also rebalancing of the phase separation states. The change of the charge-ordered insulating phase fraction was estimated to be temperature dependent, and a maximum of 16% was achieved in the phase separation regime. This tuning effect was partially irreversible, which might be due to an oxygen vacancy migration that is driven by the huge applied electric field.展开更多
基金supported by the National Natural Science Foundation of China(grant Nos.40874047 and 40574047)
文摘Global seismicity catalogs are sufficient for characterizing double seismic zones (DSZs) in subducting slab and facilitate to estimate layer separation without inconsistent uncertainties as local catalogs. Previous studies have shown the correlation between DSZs layer separation and plate age while correlation for those younger than -60 Ma is suspicious. The lacking of DSZs with layer separation less than 10 km further makes it difficult to precisely estimate such correlation. Thus, we incorporate eight DSZs data determined through local seismicity into globally-determined dataset and reexamine such correlation. The best fitting results show that both a linear model and a square root of plate age can mathematically fit the layer separation well. However, it is difficult to distinguish these two models when plate age is greater than -20 Ma since their difference is less than 2 km. However, if extrapolation is possible, both models should provide physical information that DSZs will not form if there is no subducting lithosphere. As a result, the DSZs cannot be produced until the oceanic lithospheric age becomes greater than 0.9 Ma in the square root model while the linear model gives a misleading result. As such the square root model demonstrates the relationship physically better than the linear one, it still needs further test in the future with more available data, nevertheless, our study might also provide evidence for the suggestion that the plate age is a primary control factor of the DSZs geometry as well as the subducting process which disregards any local tectonic stresses.
文摘Based on the experimental results, in which the fabricated error of the double layer frequency selective surface (FSS) leads to the transmission loss and the resonant frequency leaves away the design resonant frequency, the inter-layer separation distance (ISD) and the unit cell aligning error (UAE) were used as main variables to study the transmission performance attenuation of the double layer FSS configuration. The numerical analysis model for ISD and UAE was established and also was used to simulate the ring unit cell FSS transmission performance by the finite element and periodic moment methods. The double layer ring aperture FSS configuration designed was used as the numerical model. As a result of the numerical analysis, it is shown that both ISD and UAE produce insertion transmission loss (ITL) and insertion phase distortion (IPD) directly. Furthermore, ISD results in more loss of the amplitude of the transmitted signal for the FSS than UAE. It is significant for the designer of the multiplayer FSS to assign the fabricated error of the FSS dielectric layers. The UAE introduces the insertion phase variation badly.
基金supported by the National Basic Research Program of China(Grant Nos.2011CBA00106 and 2014CB921401)the National Natural Science Foundation of China(Grant Nos.11174342,9131208,and 11374344)
文摘Electric double-layer field effect experiments were performed on ultrathin films of La0.325Pr0.3Ca0.375MnO3, which is noted for its micrometer-scale phase separation. A clear change of resistance up to 220% was observed and the characteristic metal-insulator transition temperature Tp was also shifted. The changes of both the resistance and Tp, suggest that the electric field induced not only tuning of the carrier density but also rebalancing of the phase separation states. The change of the charge-ordered insulating phase fraction was estimated to be temperature dependent, and a maximum of 16% was achieved in the phase separation regime. This tuning effect was partially irreversible, which might be due to an oxygen vacancy migration that is driven by the huge applied electric field.