The objectives of this study are to evaluate the dosimetric impact of hip prosthesis using ELEKTA linac X-rays and compare the dose perturbations of metallic and nonmetallic hip prostheses. The local dose distribution...The objectives of this study are to evaluate the dosimetric impact of hip prosthesis using ELEKTA linac X-rays and compare the dose perturbations of metallic and nonmetallic hip prostheses. The local dose distributions of typical hip prostheses were calculated for 4, 8, and 15 MV beams by Geant4. Three prosthesis materials were selected in calculation to reveal the relation between material type and local dose perturbations of prostheses. Furthermore,the effect of nominal energy on prosthesis perturbation was also discussed and analyzed. Taking the calculated dose to the hip joint as reference, considerable differences were observed between prostheses and hip joints. In the prosthesis shadow region, the relative dose decreasing was up to 36, 21, and 16 % for the Co–Cr–Mo alloy, titanium alloy, and ceramic prostheses, respectively. In backscattering region, the relative dose increasing was about1–7 %. Overall, the results show that the dose perturbation effect of prostheses was mainly determined by material type, nominal energy, and density. Among these typical hip prostheses, ceramic prosthesis introduces the lowest dose perturbations.展开更多
X射线水吸收剂量是辐射剂量学的重要物理量,它的精确测量在放射治疗中至关重要。开展低能X射线水吸收剂量的研究与测量,可为完善水吸收剂量溯源体系及扩宽计量部门校准范围提供重要技术支持。确定低能X射线水吸收剂量的测量方法,在辐射...X射线水吸收剂量是辐射剂量学的重要物理量,它的精确测量在放射治疗中至关重要。开展低能X射线水吸收剂量的研究与测量,可为完善水吸收剂量溯源体系及扩宽计量部门校准范围提供重要技术支持。确定低能X射线水吸收剂量的测量方法,在辐射场中使用PTW23344电离室对10-50 k V的治疗水平辐射质下的X射线水吸收剂量进行了测量。最终得到了电离室的水吸收剂量刻度因子N_D以及厚度为6 cm有机玻璃前表面的水吸收剂量D_W。本项工作为建立国内X射线水吸收剂量标准及进行国际比对提供了条件和基础。展开更多
基金supported by Heilongjiang Province Natural Science Foundation (No. A200805)the Education Department of Heilongjiang Province (No. 12521425)the postdoctoral research start-up funds of Heilongjiang Province (No. LBHQ11013)
文摘The objectives of this study are to evaluate the dosimetric impact of hip prosthesis using ELEKTA linac X-rays and compare the dose perturbations of metallic and nonmetallic hip prostheses. The local dose distributions of typical hip prostheses were calculated for 4, 8, and 15 MV beams by Geant4. Three prosthesis materials were selected in calculation to reveal the relation between material type and local dose perturbations of prostheses. Furthermore,the effect of nominal energy on prosthesis perturbation was also discussed and analyzed. Taking the calculated dose to the hip joint as reference, considerable differences were observed between prostheses and hip joints. In the prosthesis shadow region, the relative dose decreasing was up to 36, 21, and 16 % for the Co–Cr–Mo alloy, titanium alloy, and ceramic prostheses, respectively. In backscattering region, the relative dose increasing was about1–7 %. Overall, the results show that the dose perturbation effect of prostheses was mainly determined by material type, nominal energy, and density. Among these typical hip prostheses, ceramic prosthesis introduces the lowest dose perturbations.
文摘X射线水吸收剂量是辐射剂量学的重要物理量,它的精确测量在放射治疗中至关重要。开展低能X射线水吸收剂量的研究与测量,可为完善水吸收剂量溯源体系及扩宽计量部门校准范围提供重要技术支持。确定低能X射线水吸收剂量的测量方法,在辐射场中使用PTW23344电离室对10-50 k V的治疗水平辐射质下的X射线水吸收剂量进行了测量。最终得到了电离室的水吸收剂量刻度因子N_D以及厚度为6 cm有机玻璃前表面的水吸收剂量D_W。本项工作为建立国内X射线水吸收剂量标准及进行国际比对提供了条件和基础。