针对10 k V配网故障复电效率低的问题,借鉴精益化管理思想,从配网调度处理故障的角度出发,分析了影响配网调度故障处理工作效率的主要因素,并得出不同接线模式的面向调度的故障处理时间模型。基于该模型,分析了具有配网接线图查找功能...针对10 k V配网故障复电效率低的问题,借鉴精益化管理思想,从配网调度处理故障的角度出发,分析了影响配网调度故障处理工作效率的主要因素,并得出不同接线模式的面向调度的故障处理时间模型。基于该模型,分析了具有配网接线图查找功能和智能开票功能的智能防误操作系统在昆明电网故障处理中的应用成效。实践证明该模型能够有效度量配网故障快速复电效率提升情况,也证明该防误操作系统能够减少故障处理时间,局部提升配网故障快速复电效率。展开更多
It is possible to understand the lightning activities in a specific region and compare test results of different apparatus only when a reliable evaluation of detection efficiency distribution pertaining to a particula...It is possible to understand the lightning activities in a specific region and compare test results of different apparatus only when a reliable evaluation of detection efficiency distribution pertaining to a particular lightning location system(LLS)is available. Based on the data in 1992.an approximate evaluation of detection efficiency spatial distribu- tion for single-station lightning location system(M-LDARS)and LLP three-station lightning loca- tion system in Beijing-Tianjin-Hebei area is presented in the paper,showing that the average detec- tion efficiencies are smaller than 48% and 46% respectively.In addition,the article offers an eval- uation of spatial distribution of ground stroke density(D_g)and positive stroke percentage,indicat- ing that six high stroke density zones exist along the southeastern sides of the Taihang and Yan- shan Mountains.The stroke density of mountainous region is higher than that of the plain region, in contrast to the case of positive stroke percentage.Also,it is shown that within a radius of 250 km,the average of D_g is 1.2(km^(-2) a^(-1))while the average positive stroke percentage is 10.9%. Finally,the paper proposes a possible test method of accurately evaluating the spatial distribution of detection efficiency(A).展开更多
文摘针对10 k V配网故障复电效率低的问题,借鉴精益化管理思想,从配网调度处理故障的角度出发,分析了影响配网调度故障处理工作效率的主要因素,并得出不同接线模式的面向调度的故障处理时间模型。基于该模型,分析了具有配网接线图查找功能和智能开票功能的智能防误操作系统在昆明电网故障处理中的应用成效。实践证明该模型能够有效度量配网故障快速复电效率提升情况,也证明该防误操作系统能够减少故障处理时间,局部提升配网故障快速复电效率。
文摘It is possible to understand the lightning activities in a specific region and compare test results of different apparatus only when a reliable evaluation of detection efficiency distribution pertaining to a particular lightning location system(LLS)is available. Based on the data in 1992.an approximate evaluation of detection efficiency spatial distribu- tion for single-station lightning location system(M-LDARS)and LLP three-station lightning loca- tion system in Beijing-Tianjin-Hebei area is presented in the paper,showing that the average detec- tion efficiencies are smaller than 48% and 46% respectively.In addition,the article offers an eval- uation of spatial distribution of ground stroke density(D_g)and positive stroke percentage,indicat- ing that six high stroke density zones exist along the southeastern sides of the Taihang and Yan- shan Mountains.The stroke density of mountainous region is higher than that of the plain region, in contrast to the case of positive stroke percentage.Also,it is shown that within a radius of 250 km,the average of D_g is 1.2(km^(-2) a^(-1))while the average positive stroke percentage is 10.9%. Finally,the paper proposes a possible test method of accurately evaluating the spatial distribution of detection efficiency(A).