Purpose:The increase in plug-in electric vehicles(PEVs)is likely to see a noteworthy impact on the distribution system due to high electric power consumption during charging and uncertainty in charging behavior.To add...Purpose:The increase in plug-in electric vehicles(PEVs)is likely to see a noteworthy impact on the distribution system due to high electric power consumption during charging and uncertainty in charging behavior.To address this problem,the present work mainly focuses on optimal integration of distributed generators(DG)into radial distribution systems in the presence of PEV loads with their charging behavior under daily load pattern including load models by considering the daily(24 h)power loss and voltage improvement of the system as objectives for better system performance.Design/methodology/approach:To achieve the desired outcomes,an efficient weighted factor multi-objective function is modeled.Particle Swarm Optimization(PSO)and Butterfly Optimization(BO)algorithms are selected and implemented to minimize the objectives of the system.A repetitive backward-forward sweep-based load flow has been introduced to calculate the daily power loss and bus voltages of the radial distribution system.The simulations are carried out using MATLAB software.Findings:The simulation outcomes reveal that the proposed approach definitely improved the system performance in all aspects.Among PSO and BO,BO is comparatively successful in achieving the desired objectives.Originality/value:The main contribution of this paper is the formulation of the multi-objective function that can address daily active power loss and voltage deviation under 24-h load pattern including grouping of residential,industrial and commercial loads.Introduction of repetitive backward-forward sweep-based load flow and the modeling of PEV load with two different charging scenarios.展开更多
There are various types of distributed generators (DGs) with different grid integration strategies. The transient characteristics of the fault currents provided by the DGs are different to those of conventional synchr...There are various types of distributed generators (DGs) with different grid integration strategies. The transient characteristics of the fault currents provided by the DGs are different to those of conventional synchronous generators. In this paper, a distribution network with multi-type DGs is investigated, including consideration of DG low-voltage ride through (LVRT). The fault current characteristics of two typical DGs, i.e. an inverter-interfaced distributed generator (IIDG) and a doubly-fed induction generator (DFIG), are analyzed, considering the specific operation modes. Based on analysis of the fault characteristics, an equivalent model of the multi-type DGs under symmetrical/asymmetrical fault conditions is established. A fast-iterative fault calculation method for enhancing the calculation efficiency while avoiding local convergence is then proposed using an improved particle swarm optimization (PSO) algorithm. A simulation system of the distribution network with multi-type DGs is established in PSCAD/EMTDC. The simulation results validate the high accuracy and calculation efficiency of the proposed calculation method of the fault components. This can assist in the settings of the protection threshold.展开更多
基金Proposal Number:EEQ-2016-000263,Financially supported by Department of Science and Technology(DST),Science and Engineering Research Board(SERB),Govt.of India,New Delhi,India.
文摘Purpose:The increase in plug-in electric vehicles(PEVs)is likely to see a noteworthy impact on the distribution system due to high electric power consumption during charging and uncertainty in charging behavior.To address this problem,the present work mainly focuses on optimal integration of distributed generators(DG)into radial distribution systems in the presence of PEV loads with their charging behavior under daily load pattern including load models by considering the daily(24 h)power loss and voltage improvement of the system as objectives for better system performance.Design/methodology/approach:To achieve the desired outcomes,an efficient weighted factor multi-objective function is modeled.Particle Swarm Optimization(PSO)and Butterfly Optimization(BO)algorithms are selected and implemented to minimize the objectives of the system.A repetitive backward-forward sweep-based load flow has been introduced to calculate the daily power loss and bus voltages of the radial distribution system.The simulations are carried out using MATLAB software.Findings:The simulation outcomes reveal that the proposed approach definitely improved the system performance in all aspects.Among PSO and BO,BO is comparatively successful in achieving the desired objectives.Originality/value:The main contribution of this paper is the formulation of the multi-objective function that can address daily active power loss and voltage deviation under 24-h load pattern including grouping of residential,industrial and commercial loads.Introduction of repetitive backward-forward sweep-based load flow and the modeling of PEV load with two different charging scenarios.
基金supported by National Natural Science Foundation of China under Grant 51807091the China Postdoctoral Science Foundation under Grant 2019M661846Open Research Fund of Key Laboratory of Power System Intelligent Dispatch and Control of Ministry of Education,EPSRC under Grant EP/N032888/1,and the International Science and Technology Collaborative Project of Policy Guidance Plan of Jiangsu Province under Grant BZ2018026.
文摘There are various types of distributed generators (DGs) with different grid integration strategies. The transient characteristics of the fault currents provided by the DGs are different to those of conventional synchronous generators. In this paper, a distribution network with multi-type DGs is investigated, including consideration of DG low-voltage ride through (LVRT). The fault current characteristics of two typical DGs, i.e. an inverter-interfaced distributed generator (IIDG) and a doubly-fed induction generator (DFIG), are analyzed, considering the specific operation modes. Based on analysis of the fault characteristics, an equivalent model of the multi-type DGs under symmetrical/asymmetrical fault conditions is established. A fast-iterative fault calculation method for enhancing the calculation efficiency while avoiding local convergence is then proposed using an improved particle swarm optimization (PSO) algorithm. A simulation system of the distribution network with multi-type DGs is established in PSCAD/EMTDC. The simulation results validate the high accuracy and calculation efficiency of the proposed calculation method of the fault components. This can assist in the settings of the protection threshold.