Recently microgrids have drawn a potential attraction by fulfilling the environmental demands and the increasing energy demands of the end-users. It is necessary to focus on various protection and control aspects of a...Recently microgrids have drawn a potential attraction by fulfilling the environmental demands and the increasing energy demands of the end-users. It is necessary to focus on various protection and control aspects of a microgrid. During the transition between the grid-following and grid-forming modes, the voltage and the frequency instability due to the power mismatch condition becomes the major point of concern. Therefore, the paper executes a frequency-active power and voltage-reactive power drooping control strategy for the precise power-sharing among the distributed power generators. Furthermore, to handle the power deficit scenarios and to maintain the system stability, a system independent and priority-based adaptive three-stage load shedding strategy is proposed. The sensitivity of the strategy depends on the system inertia and is computed according to the varying absolute rate-of-change-of-frequency. The strategy incorporates the operation of battery storage system and distributed static compensator (D-STATCOM) in the microgrid, to provide a reliable power supply to the customers for a considerable time instead of a sudden load shedding. The effectiveness of the proposed strategies is investigated on a scaled-down modified IEEE 13-bus microgrid system on the podium of MATLAB 2015b through the time-domain simulation.展开更多
When large-scale distributed renewable energy power generation systems are connected to the power grid,the risk of grid voltage fluctuations and exceeding the limit increases greatly.Fortunately,the on-load tap change...When large-scale distributed renewable energy power generation systems are connected to the power grid,the risk of grid voltage fluctuations and exceeding the limit increases greatly.Fortunately,the on-load tap changer(OLTC)can adjust the transformer winding tap to maintain the secondary side voltage within the normal range.However,the inevitable delay in switching transformer taps makes it difficult to respond quickly to voltage fluctuations.Moreover,switching the transformer taps frequently will decrease the service life of OLTC.In order to solve this critical issue,a cooperative voltage regulation strategy applied between the battery energy storage systems(BESSs)and OLTSs.is proposed By adjusting the charge and discharge power of BESSs,the OLTC can frequently switch the transformer taps to achieve rapid voltage regulation.The effectiveness of the proposed coordinated regulation strategy is verified in the IEEE 33 node distribution systems.The simulation results show that the proposed coordinated regulation strategy can stabilize the voltage of the distribution network within a normal range and reduce the frequency of tap switching,as such elongating the service life of the equipment.展开更多
A smart grid will require, to greater or lesser degrees, advanced tools for planning and operation, broadly accepted communications platforms, smart sensors and controls, and real-time pricing. The smart grid has been...A smart grid will require, to greater or lesser degrees, advanced tools for planning and operation, broadly accepted communications platforms, smart sensors and controls, and real-time pricing. The smart grid has been described as something of an ecosystem with constantly communication, proactive, and virtually self-aware. The use of smart grid has a lot of economical and environmental advantages;however it has a downside of instability and unpredictability introduced by distributed generation (DG) from renewable energy into the public electric systems. Variable energies such as solar and wind power have a lack of stability and to avoid short-term fluctuations in power supplied to the grid, a local storage subsystem could be used to provide higher quality and stability in the fed energy. Energy storage systems (ESSs) would be a facilitator of smart grid deployment and a “small amount” of storage would have a “great impact” on the future power grid. The smart grid, with its various superior communications and control features, would make it possible to integrate the potential application of widely dispersed battery storage systems as well other ESSs. This work deals with a detailed updated review on available ESSs applications in future smart power grids. It also highlights latest projects carried out on different ESSs throughout all around the world.展开更多
As a typical scenario of distributed integrated multi-energy system(DIMS),industrial park contains complex production constraints and strong associations between industrial productions and energy demands.The industria...As a typical scenario of distributed integrated multi-energy system(DIMS),industrial park contains complex production constraints and strong associations between industrial productions and energy demands.The industrial production process(IPP)consists of controllable subtasks and strict timing constraints.Taking IPP as a control variable of optimal scheduling,it is an available approach that models the IPP as material flow into an extension energy hub(EH)to achieve the optimization of industrial park.In this paper,considering the coupling between the production process and energy demands,a model of IPP is proposed by dividing the process into different adjustable steps,including continuous subtask,discrete subtask,and storage subtask.Then,a transport model of material flow is used to describe the IPP in an industrial park DIMS.Based on the concept of EH,a universal extension EH model is proposed considering the coupling among electricity,heat,cooling,and material.Furthermore,an optimal scheduling method for industrial park DIMS is proposed to improve the energy efficiency and operation economy.Finally,a case study of a typical battery factory is shown to illustrate the proposed method.The simulation results demonstrate that such a method reduces the operation cost and accurately reflects the operation state of the industrial factory.展开更多
The foremost issues of 21st century are challenging demand of electrical energy and to control the emission of Green House Gases(GHG)emissions.Renewable energy resources based sustainable microgrid emerges as one of t...The foremost issues of 21st century are challenging demand of electrical energy and to control the emission of Green House Gases(GHG)emissions.Renewable energy resources based sustainable microgrid emerges as one of the best feasible solution for future energy demand while considering zero carbon emission,fossil fuel independency,and enhanced reliability.In this paper,optimization and implementation of institutional based sustainable microgrid are discussed based on cost analysis,carbon emission,and availability of energy resources.Various microgrid topologies are considered for addressing the most ideal solution.The metrological data such as irradiance is acquired from solar satellite data of NASA(National Aero Space Agency)while the data for wind speed is taken from synergy enviro engineer’s site.HOMER®simulation tool is used for modelling and optimization purpose.展开更多
文摘Recently microgrids have drawn a potential attraction by fulfilling the environmental demands and the increasing energy demands of the end-users. It is necessary to focus on various protection and control aspects of a microgrid. During the transition between the grid-following and grid-forming modes, the voltage and the frequency instability due to the power mismatch condition becomes the major point of concern. Therefore, the paper executes a frequency-active power and voltage-reactive power drooping control strategy for the precise power-sharing among the distributed power generators. Furthermore, to handle the power deficit scenarios and to maintain the system stability, a system independent and priority-based adaptive three-stage load shedding strategy is proposed. The sensitivity of the strategy depends on the system inertia and is computed according to the varying absolute rate-of-change-of-frequency. The strategy incorporates the operation of battery storage system and distributed static compensator (D-STATCOM) in the microgrid, to provide a reliable power supply to the customers for a considerable time instead of a sudden load shedding. The effectiveness of the proposed strategies is investigated on a scaled-down modified IEEE 13-bus microgrid system on the podium of MATLAB 2015b through the time-domain simulation.
基金Supported by the Postdoctoral Science Foundation of China(No.2022M710039)。
文摘When large-scale distributed renewable energy power generation systems are connected to the power grid,the risk of grid voltage fluctuations and exceeding the limit increases greatly.Fortunately,the on-load tap changer(OLTC)can adjust the transformer winding tap to maintain the secondary side voltage within the normal range.However,the inevitable delay in switching transformer taps makes it difficult to respond quickly to voltage fluctuations.Moreover,switching the transformer taps frequently will decrease the service life of OLTC.In order to solve this critical issue,a cooperative voltage regulation strategy applied between the battery energy storage systems(BESSs)and OLTSs.is proposed By adjusting the charge and discharge power of BESSs,the OLTC can frequently switch the transformer taps to achieve rapid voltage regulation.The effectiveness of the proposed coordinated regulation strategy is verified in the IEEE 33 node distribution systems.The simulation results show that the proposed coordinated regulation strategy can stabilize the voltage of the distribution network within a normal range and reduce the frequency of tap switching,as such elongating the service life of the equipment.
文摘A smart grid will require, to greater or lesser degrees, advanced tools for planning and operation, broadly accepted communications platforms, smart sensors and controls, and real-time pricing. The smart grid has been described as something of an ecosystem with constantly communication, proactive, and virtually self-aware. The use of smart grid has a lot of economical and environmental advantages;however it has a downside of instability and unpredictability introduced by distributed generation (DG) from renewable energy into the public electric systems. Variable energies such as solar and wind power have a lack of stability and to avoid short-term fluctuations in power supplied to the grid, a local storage subsystem could be used to provide higher quality and stability in the fed energy. Energy storage systems (ESSs) would be a facilitator of smart grid deployment and a “small amount” of storage would have a “great impact” on the future power grid. The smart grid, with its various superior communications and control features, would make it possible to integrate the potential application of widely dispersed battery storage systems as well other ESSs. This work deals with a detailed updated review on available ESSs applications in future smart power grids. It also highlights latest projects carried out on different ESSs throughout all around the world.
基金supported by the National Nature Science Foundation of China(No.51977005)
文摘As a typical scenario of distributed integrated multi-energy system(DIMS),industrial park contains complex production constraints and strong associations between industrial productions and energy demands.The industrial production process(IPP)consists of controllable subtasks and strict timing constraints.Taking IPP as a control variable of optimal scheduling,it is an available approach that models the IPP as material flow into an extension energy hub(EH)to achieve the optimization of industrial park.In this paper,considering the coupling between the production process and energy demands,a model of IPP is proposed by dividing the process into different adjustable steps,including continuous subtask,discrete subtask,and storage subtask.Then,a transport model of material flow is used to describe the IPP in an industrial park DIMS.Based on the concept of EH,a universal extension EH model is proposed considering the coupling among electricity,heat,cooling,and material.Furthermore,an optimal scheduling method for industrial park DIMS is proposed to improve the energy efficiency and operation economy.Finally,a case study of a typical battery factory is shown to illustrate the proposed method.The simulation results demonstrate that such a method reduces the operation cost and accurately reflects the operation state of the industrial factory.
文摘The foremost issues of 21st century are challenging demand of electrical energy and to control the emission of Green House Gases(GHG)emissions.Renewable energy resources based sustainable microgrid emerges as one of the best feasible solution for future energy demand while considering zero carbon emission,fossil fuel independency,and enhanced reliability.In this paper,optimization and implementation of institutional based sustainable microgrid are discussed based on cost analysis,carbon emission,and availability of energy resources.Various microgrid topologies are considered for addressing the most ideal solution.The metrological data such as irradiance is acquired from solar satellite data of NASA(National Aero Space Agency)while the data for wind speed is taken from synergy enviro engineer’s site.HOMER®simulation tool is used for modelling and optimization purpose.