Earthquake performance of a flexible one-story building isolated with a variable frequency pendulum isolator (VFPI) under near-fault and far-field ground motions is investigated. The frictional forces mobilized at t...Earthquake performance of a flexible one-story building isolated with a variable frequency pendulum isolator (VFPI) under near-fault and far-field ground motions is investigated. The frictional forces mobilized at the interface of the VFPI are assumed to be velocity dependent. The interaction between frictional forces of the VFPI in two horizontal directions is duly considered and coupled differential equations of motion of the isolated system in the incremental form are solved iteratively. The response of the system with bi-directional interaction is compared with those without interaction. In addition, the effects of velocity dependence on the response of the isolated system are also investigated. Moreover, a parametric study is carried out to critically examine the influence of important parameters on bi-directional interaction effects of the frictional forces of the VFPI. These parameters are: the superstructure time period, frequency variation factor (FVF) and friction coefficient of the VFPI. From the above investigations, it is observed that the dependence of the friction coefficient on relative velocity of the system does not have a noticeable effect on the peak response of the system isolated with VFPI, and that the bi-directional interaction of frictional forces of the VFPI is important and if neglected, isolator displacements will be underestimated and the superstructure acceleration and base shear will be overestimated.展开更多
Seismic response of ground supported baseisolated liquid storage tanks are evaluated under bi-directional earthquakes. The base-isolated liquid storage tanks are modeled using mechanical analogs with two and three lum...Seismic response of ground supported baseisolated liquid storage tanks are evaluated under bi-directional earthquakes. The base-isolated liquid storage tanks are modeled using mechanical analogs with two and three lumped masses (Model 1 and Model 2). Two types of isolation systems, such as sliding system and elastomeric system, are considered for the present study. The isolation systems are modeled using Wen’s equation for hysteretic isolation systems. Response of base-isolated liquid storage tanks, evaluated through two different modeling approaches, is compared. Both the models predict similar sloshing displacement. The effect of interaction between the mutually perpendicular seismic responses of the isolator is investigated for both the models. It is observed that interaction affects the peak seismic response of the base-isolated liquid storage tanks significantly, under the bi-directional earthquake components.展开更多
文摘Earthquake performance of a flexible one-story building isolated with a variable frequency pendulum isolator (VFPI) under near-fault and far-field ground motions is investigated. The frictional forces mobilized at the interface of the VFPI are assumed to be velocity dependent. The interaction between frictional forces of the VFPI in two horizontal directions is duly considered and coupled differential equations of motion of the isolated system in the incremental form are solved iteratively. The response of the system with bi-directional interaction is compared with those without interaction. In addition, the effects of velocity dependence on the response of the isolated system are also investigated. Moreover, a parametric study is carried out to critically examine the influence of important parameters on bi-directional interaction effects of the frictional forces of the VFPI. These parameters are: the superstructure time period, frequency variation factor (FVF) and friction coefficient of the VFPI. From the above investigations, it is observed that the dependence of the friction coefficient on relative velocity of the system does not have a noticeable effect on the peak response of the system isolated with VFPI, and that the bi-directional interaction of frictional forces of the VFPI is important and if neglected, isolator displacements will be underestimated and the superstructure acceleration and base shear will be overestimated.
文摘Seismic response of ground supported baseisolated liquid storage tanks are evaluated under bi-directional earthquakes. The base-isolated liquid storage tanks are modeled using mechanical analogs with two and three lumped masses (Model 1 and Model 2). Two types of isolation systems, such as sliding system and elastomeric system, are considered for the present study. The isolation systems are modeled using Wen’s equation for hysteretic isolation systems. Response of base-isolated liquid storage tanks, evaluated through two different modeling approaches, is compared. Both the models predict similar sloshing displacement. The effect of interaction between the mutually perpendicular seismic responses of the isolator is investigated for both the models. It is observed that interaction affects the peak seismic response of the base-isolated liquid storage tanks significantly, under the bi-directional earthquake components.
文摘基于传统微带线定向耦合器的方向性和耦合性,利用端口阻抗的失配效应,设计出一种隔离度高、方向性好的改进型耦合器。测试结果表明,改进后定向耦合器的隔离度大大提高,在中心频率915MHz 处隔离度高达58.875dB,方向性约为45dB,能有效抑制载波泄漏到接收链路中,能很好地满足902MHz~928MHz 频段 RFID 阅读器收发隔离的需求。