This study was aimed at mapping the subsurface extent of saline water intrusions into aquifers at the eastern part of Dahomey basin, Nigeria. The study adopted geoelectric sounding methods. 108 vertical electrical sou...This study was aimed at mapping the subsurface extent of saline water intrusions into aquifers at the eastern part of Dahomey basin, Nigeria. The study adopted geoelectric sounding methods. 108 vertical electrical soundings (VES) and 9 induced polarization soundings (IPS) data were acquired using Schlumberger array technique. Three aquifer units were delineated across the study area. The resistivity of the first, second and third aquifer layers varies from 0.2 to 1569 ohm-m, 0.5 to 904 ohm-m and 0.4 to 665 ohm-m respectively, while depth to the top of first, second and third aquifer varies respectively from 0.7 to 151.5 m, 1.4 to 305.5 m and 12.9 to 452.9 m. The depth to the first aquifer layer is shallow (less than 5 m) in the coastal area which makes this area to be highly vulnerable to anthropogenic pollution while their proximity to Atlantic Ocean makes them susceptible to saline water intrusion. In all the three aquifer units, the coastal area, Agbabu and other few locations in the mainland are characterized by low resistivity values (below 60 ohm-m) indicating possible presence of brackish or saline water. IP sounding results showed that all the low resistive layers in the mainland are characterized by clayey materials. The integration of VES and IPS results enabled the delineation of the saline water lateral extent across the study area. There is a strong direct correlation (r2 = 0.8564) between location distance from the saline water source and depth to saline water in the study area. This can therefore serve as a predictive model to determine depth to saline water at any location within the saline water zone in the study area.展开更多
The current parameter estimation algorithms of chirp rate have high complexity and long calculation time,meantime they are difficult to achieve high estimation rate. Therefore,in order to overcome these problems,in th...The current parameter estimation algorithms of chirp rate have high complexity and long calculation time,meantime they are difficult to achieve high estimation rate. Therefore,in order to overcome these problems,in this paper,a new parameter estimation algorithm based on Holder coefficient is presented. Firstly,this algorithm calculates the correlation curve of the Holder coefficient value under different chirp rate. Secondly,this algorithm calculates the correlation curve under different SNR. Finally,the fitting curve expression can be got by the correlation curve,and then the estimation value of chirp rate can also be got. The theory analysis and simulation results show that this algorithm is simple and easy to realize,and has much better application value for real-time estimation.展开更多
文摘This study was aimed at mapping the subsurface extent of saline water intrusions into aquifers at the eastern part of Dahomey basin, Nigeria. The study adopted geoelectric sounding methods. 108 vertical electrical soundings (VES) and 9 induced polarization soundings (IPS) data were acquired using Schlumberger array technique. Three aquifer units were delineated across the study area. The resistivity of the first, second and third aquifer layers varies from 0.2 to 1569 ohm-m, 0.5 to 904 ohm-m and 0.4 to 665 ohm-m respectively, while depth to the top of first, second and third aquifer varies respectively from 0.7 to 151.5 m, 1.4 to 305.5 m and 12.9 to 452.9 m. The depth to the first aquifer layer is shallow (less than 5 m) in the coastal area which makes this area to be highly vulnerable to anthropogenic pollution while their proximity to Atlantic Ocean makes them susceptible to saline water intrusion. In all the three aquifer units, the coastal area, Agbabu and other few locations in the mainland are characterized by low resistivity values (below 60 ohm-m) indicating possible presence of brackish or saline water. IP sounding results showed that all the low resistive layers in the mainland are characterized by clayey materials. The integration of VES and IPS results enabled the delineation of the saline water lateral extent across the study area. There is a strong direct correlation (r2 = 0.8564) between location distance from the saline water source and depth to saline water in the study area. This can therefore serve as a predictive model to determine depth to saline water at any location within the saline water zone in the study area.
基金Sponsored by the Nation Nature Science Foundation of China(Grant No.61201237)the Nature Science Foundation of Heilongjiang Province of China(Grant No.QC2012C069)the Fundamental Research Funds for the Central Universities(Grant No.HEUCFZ1129,HEUCF130810,HEUCF130817)
文摘The current parameter estimation algorithms of chirp rate have high complexity and long calculation time,meantime they are difficult to achieve high estimation rate. Therefore,in order to overcome these problems,in this paper,a new parameter estimation algorithm based on Holder coefficient is presented. Firstly,this algorithm calculates the correlation curve of the Holder coefficient value under different chirp rate. Secondly,this algorithm calculates the correlation curve under different SNR. Finally,the fitting curve expression can be got by the correlation curve,and then the estimation value of chirp rate can also be got. The theory analysis and simulation results show that this algorithm is simple and easy to realize,and has much better application value for real-time estimation.