Unlike the pier scour in bridge waterways,the local scour at offshore monopile foundations should take into account the effect of wave-current combination.Under the condition of wave-current coexistence,the water-soil...Unlike the pier scour in bridge waterways,the local scour at offshore monopile foundations should take into account the effect of wave-current combination.Under the condition of wave-current coexistence,the water-soil interfacial scouring is usually coupled with the pore-pressure dynamics inside of the seabed.The aforementioned wave/current-pile-soil coupling process was physically modeled with a specially designed flow-structure-soil interaction flume.Experimental results indicate that superimposing a current onto the waves obviously changes the pore-pressure and the flow velocity at the bed around the pile.The concomitance of horseshoe vortex and local scour hole around a monopile proves that the horseshoe vortex is one of the main controlling mechanisms for scouring development under the combined waves and current.Based on similarity analyses,an average-velocity based Froude number(Fra)is proposed to correlate with the equilibrium scour depth(S/D)at offshore monopile foundation in the combined waves and current.An empirical expression for the correlation between S/D and Fra is given for predicting equilibrium scour depth,which may provide a guide for offshore engineering practice.展开更多
Film cooling combined with internal impingement cooling is one of the most effective technologies to protect the gas turbine vanes and blades from the hot gas. In this study, conjugate heat transfer CFD study was unde...Film cooling combined with internal impingement cooling is one of the most effective technologies to protect the gas turbine vanes and blades from the hot gas. In this study, conjugate heat transfer CFD study was undertaken for a flat plate with combined film cooling and impingement cooling. An experiment on conjugate heat transfer of a flat plate with combined film and impingement cooling was performed to validate the code. Then the effects of several parameters including Biot number, blowing ratio, film hole shape and impingement hole diameter on the overall cooling effectiveness were numerically studied. The results show that for a specific combined cooling scheme and a given blowing ratio, the coolant potential can be reasonably allocated to the internal and the external cooling to achieve the overall cooling effectiveness. As the blowing ratio increases, the overall cooling effectiveness trends to reach a maximum value. For different film hole geometrical, the maximum values of the overall cooling effectiveness at high blowing ratio approximate to the same value. At a given mass flow rate of coolant, the increase of the impingement hole diameter leads to the reduction of the overall cooling effectiveness.展开更多
基金supported by the National Natural Science Foundation of China(Grant Nos.1123201210872198)the National Basic Research Program of China("973"Project)(Grant No.2014CB046204)
文摘Unlike the pier scour in bridge waterways,the local scour at offshore monopile foundations should take into account the effect of wave-current combination.Under the condition of wave-current coexistence,the water-soil interfacial scouring is usually coupled with the pore-pressure dynamics inside of the seabed.The aforementioned wave/current-pile-soil coupling process was physically modeled with a specially designed flow-structure-soil interaction flume.Experimental results indicate that superimposing a current onto the waves obviously changes the pore-pressure and the flow velocity at the bed around the pile.The concomitance of horseshoe vortex and local scour hole around a monopile proves that the horseshoe vortex is one of the main controlling mechanisms for scouring development under the combined waves and current.Based on similarity analyses,an average-velocity based Froude number(Fra)is proposed to correlate with the equilibrium scour depth(S/D)at offshore monopile foundation in the combined waves and current.An empirical expression for the correlation between S/D and Fra is given for predicting equilibrium scour depth,which may provide a guide for offshore engineering practice.
基金financial support from the National Natural Science Foundation of China under Grant No.51776201the National Science Foundation of Tianjin under Grant No.18JCQNJC07200。
文摘Film cooling combined with internal impingement cooling is one of the most effective technologies to protect the gas turbine vanes and blades from the hot gas. In this study, conjugate heat transfer CFD study was undertaken for a flat plate with combined film cooling and impingement cooling. An experiment on conjugate heat transfer of a flat plate with combined film and impingement cooling was performed to validate the code. Then the effects of several parameters including Biot number, blowing ratio, film hole shape and impingement hole diameter on the overall cooling effectiveness were numerically studied. The results show that for a specific combined cooling scheme and a given blowing ratio, the coolant potential can be reasonably allocated to the internal and the external cooling to achieve the overall cooling effectiveness. As the blowing ratio increases, the overall cooling effectiveness trends to reach a maximum value. For different film hole geometrical, the maximum values of the overall cooling effectiveness at high blowing ratio approximate to the same value. At a given mass flow rate of coolant, the increase of the impingement hole diameter leads to the reduction of the overall cooling effectiveness.