期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
基于阻抗谱的同轴电力电缆高频传输特性研究 被引量:7
1
作者 张丹丹 郑建康 +5 位作者 冯南战 黎立 刘翔 苏小婷 褚子平 李少斌 《高压电器》 CAS CSCD 北大核心 2021年第6期18-23,共6页
电缆的传播常数、特征阻抗、相速度的高频特性表征了电缆的高频传输特性,而准确获取电缆的高频传输特性是电缆故障定位的基础。文中针对现有测试技术的不足,提出了基于电缆阻抗谱的同轴电力电缆高频传输特性获取方法,研究结果表明:在300... 电缆的传播常数、特征阻抗、相速度的高频特性表征了电缆的高频传输特性,而准确获取电缆的高频传输特性是电缆故障定位的基础。文中针对现有测试技术的不足,提出了基于电缆阻抗谱的同轴电力电缆高频传输特性获取方法,研究结果表明:在300 kHz~100 MHz频率范围,随着频率的增大,衰减常数和相移系数近似线性增大;相速度随频率的增大略有增加,并趋于稳定值;受测量接线处附加电感和附加电容的影响,特征阻抗的高频特性出现较为严重的畸变。 展开更多
关键词 同轴电力电缆 阻抗谱 传播常数 相速度 特征阻抗
下载PDF
Design and manufacture of a 100 kA coaxial pulsed power cable for plasma generator and PPS in ETC guns 被引量:1
2
作者 Yong Jin Zhen-xiao Li +4 位作者 Yan-jie Ni Xiao-ya Gao Gang Wan Chun-xia Yang Bao-ming Li 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2019年第5期698-702,共5页
Based on our previous pulsed current and internal overvoltage test data and the experience of common commercial high power cables,a 100 kA coaxial pulsed power cable is designed and manufactured to adapt the coaxial e... Based on our previous pulsed current and internal overvoltage test data and the experience of common commercial high power cables,a 100 kA coaxial pulsed power cable is designed and manufactured to adapt the coaxial electric energy breech transmission between the plasma generator and the pulsed power supply(PPS) in electrothermal-chemical(ETC) guns.The index parameters are analyzed and determined.Semi-conductor layers and a shield stiffener are introduced to prevent the deformation and burst of the pulsed power cable structurally.The semi-conductor layer can eliminate the air gap and balance the electric field in the cable.The shield stiffener can multiply the mechanical strength to restrain the strong electrodynamic force produced by the core dislocation of the outer conductor.The multi-coupling of electromagnetic field,stress field and thermal field analysis are established to assist in aided design of electrical strength,mechanical strength and temperature rise characteristics.Both a DC voltage withstand test and pulsed discharge tests are introduced to verify and inspect the performance and dynamic response of the pulsed power cable.The 25 kV/5 min DC voltage withstand test result shows that the sample leakage current is nearly 3 μA and no abnormal phenomena of the pulsed power cable sample occurred.The pulsed discharge tests show that the sample can sustain the 100 kA peak current.Furthermore,this 100 kA coaxial pulsed power cable can satisfy the ETC test requirements. 展开更多
关键词 PULSED power cable PULSED power supply Electrothermal-chemical LAUNCH coaxial structure
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部