Modal parameter identification is a mature technology.However,there are some challenges in its practical applications such as the identification of vibration systems involving closely spaced modes and intensive noise ...Modal parameter identification is a mature technology.However,there are some challenges in its practical applications such as the identification of vibration systems involving closely spaced modes and intensive noise contamination.This paper proposes a new time-frequency method based on intrinsic chirp component decomposition(ICCD)to address these issues.In this method,a redundant Fourier model is used to ameliorate border distortions and improve the accuracy of signal reconstruction.The effectiveness and accuracy of the proposed method are illustrated using three examples:a cantilever beam structure with intensive noise contamination or environmental interference,a four-degree-of-freedom structure with two closely spaced modes,and an impact test on a cantilever rectangular plate.By comparison with the identification method based on the empirical wavelet transform(EWT),it is shown that the presented method is effective,even in a high-noise environment,and the dynamic characteristics of closely spaced modes are accurately determined.展开更多
A new quantitative concept is introduced in this paper, which may be used to facilitate the measurement of the controllability of a subspace similar to subspace controllability degree. Then the concrete form of the su...A new quantitative concept is introduced in this paper, which may be used to facilitate the measurement of the controllability of a subspace similar to subspace controllability degree. Then the concrete form of the subspace controllability degree of a flexible structure is derived, and the errors of subspace controllability degree and dynamical response caused by the substitution of a repeated mode subspace for a closely spaced mode subspace are discussed. All the results show that this substitution is rational under some conditions.展开更多
文摘针对水电站厂房结构模态识别问题,建立了一种密集模态识别的组合方法。该方法通过将逆衰减指数窗和小波包分频结合,实现了降低振动信号的模态密集度,提高了模态分离的精度。振动信号模态分离后采用Random Decrement Technique(RDT)和Spare Time Domain(STD)方法识别水电站厂房结构的模态参数。以一大型地下水电站厂房结构为分析对象,对其原型振动测试数据开展了密集模态识别。结果表明,采用该组合方法识别结果与三维有限元计算结果一致,且识别出的阻尼比也处在合理范围之内。
基金Project supported by the National Natural Science Foundation of China(Nos.11702170,11320011,and 11802279)the China Postdoctoral Science Foundation(No.2016M601585)
文摘Modal parameter identification is a mature technology.However,there are some challenges in its practical applications such as the identification of vibration systems involving closely spaced modes and intensive noise contamination.This paper proposes a new time-frequency method based on intrinsic chirp component decomposition(ICCD)to address these issues.In this method,a redundant Fourier model is used to ameliorate border distortions and improve the accuracy of signal reconstruction.The effectiveness and accuracy of the proposed method are illustrated using three examples:a cantilever beam structure with intensive noise contamination or environmental interference,a four-degree-of-freedom structure with two closely spaced modes,and an impact test on a cantilever rectangular plate.By comparison with the identification method based on the empirical wavelet transform(EWT),it is shown that the presented method is effective,even in a high-noise environment,and the dynamic characteristics of closely spaced modes are accurately determined.
基金The project supported by the National Natural Science Foundation of Chinathe Doctoral Research Foundation of Chinese Ministry of Education.
文摘A new quantitative concept is introduced in this paper, which may be used to facilitate the measurement of the controllability of a subspace similar to subspace controllability degree. Then the concrete form of the subspace controllability degree of a flexible structure is derived, and the errors of subspace controllability degree and dynamical response caused by the substitution of a repeated mode subspace for a closely spaced mode subspace are discussed. All the results show that this substitution is rational under some conditions.