The Duke storage ring is a dedicated driver for the storage ring based oscillator free-electron lasers(FELs), and the High Intensity Gamma-ray Source(HIGS). It is operated with a beam current ranging from about1 m...The Duke storage ring is a dedicated driver for the storage ring based oscillator free-electron lasers(FELs), and the High Intensity Gamma-ray Source(HIGS). It is operated with a beam current ranging from about1 mA to 100 mA per bunch for various operations and accelerator physics studies. High performance operations of the FEL and γ-ray source require a stable electron beam orbit, which has been realized by the global orbit feedback system. As a critical part of the orbit feedback system, the electron beam position monitors(BPMs) are required to be able to precisely measure the electron beam orbit in a wide range of the single-bunch current. However, the high peak voltage of the BPM pickups associated with high single-bunch current degrades the performance of the BPM electronics, and can potentially damage the BPM electronics. A signal conditioning method using low pass filters is developed to reduce the peak voltage to protect the BPM electronics, and to make the BPMs capable of working with a wide range of single-bunch current. Simulations and electron beam based tests are performed. The results show that the Duke storage ring BPM system is capable of providing precise orbit measurements to ensure highly stable FEL and HIGS operations.展开更多
Effect of multiple respiratory gas monitoring (MRGM ) on inspiredconcentration of oxygen in circult system during closed anesthesia was studied in 5l adult patients scheduled for abdominal surgery. Required flow rate ...Effect of multiple respiratory gas monitoring (MRGM ) on inspiredconcentration of oxygen in circult system during closed anesthesia was studied in 5l adult patients scheduled for abdominal surgery. Required flow rate of fresh oxygen (OFR), inspired oxygen concentration (FiO2 ) and oxygen saturation of pulse oximeter (SpO2) were measured continu0usly. Patients were equally divided into three groups at randorn, group C (no MRGN used ), group M, (using MRGM with its tail gas returned to circuit system), group M2 (using MRGM without tail gas returned ). The results revealed that during 180 min of closed anesthesia, OFR required in group C and M, were about 200-230 ml/min, and in group M, it was ab0ut 400 ml/min. In group C FiO2 decreased by about 10 % after 60 min of closed anesthesia (P<0. 01, 60 min vs 0 min ) and then stayed stable at this level. In group M,, FiO2 decreased by 16% at 60 min and 34 % at 180 min and the decrease was significantly greater than that in gr0up C (P<0. 01). In group Me, FiO2 remained c0nstant during closed anesthesia, which was much high(Jr than those in group C and M,. The tail gas of Capnomac Ultima MRGM contained less oxygen than its sample gas drawn fr0m circuit system simuItaneously.展开更多
基金Supported by US Department of Energy(DE-FG02-97ER41033)Fundamental Research Funds for the Central Universities of China(WK2310000032)
文摘The Duke storage ring is a dedicated driver for the storage ring based oscillator free-electron lasers(FELs), and the High Intensity Gamma-ray Source(HIGS). It is operated with a beam current ranging from about1 mA to 100 mA per bunch for various operations and accelerator physics studies. High performance operations of the FEL and γ-ray source require a stable electron beam orbit, which has been realized by the global orbit feedback system. As a critical part of the orbit feedback system, the electron beam position monitors(BPMs) are required to be able to precisely measure the electron beam orbit in a wide range of the single-bunch current. However, the high peak voltage of the BPM pickups associated with high single-bunch current degrades the performance of the BPM electronics, and can potentially damage the BPM electronics. A signal conditioning method using low pass filters is developed to reduce the peak voltage to protect the BPM electronics, and to make the BPMs capable of working with a wide range of single-bunch current. Simulations and electron beam based tests are performed. The results show that the Duke storage ring BPM system is capable of providing precise orbit measurements to ensure highly stable FEL and HIGS operations.
文摘Effect of multiple respiratory gas monitoring (MRGM ) on inspiredconcentration of oxygen in circult system during closed anesthesia was studied in 5l adult patients scheduled for abdominal surgery. Required flow rate of fresh oxygen (OFR), inspired oxygen concentration (FiO2 ) and oxygen saturation of pulse oximeter (SpO2) were measured continu0usly. Patients were equally divided into three groups at randorn, group C (no MRGN used ), group M, (using MRGM with its tail gas returned to circuit system), group M2 (using MRGM without tail gas returned ). The results revealed that during 180 min of closed anesthesia, OFR required in group C and M, were about 200-230 ml/min, and in group M, it was ab0ut 400 ml/min. In group C FiO2 decreased by about 10 % after 60 min of closed anesthesia (P<0. 01, 60 min vs 0 min ) and then stayed stable at this level. In group M,, FiO2 decreased by 16% at 60 min and 34 % at 180 min and the decrease was significantly greater than that in gr0up C (P<0. 01). In group Me, FiO2 remained c0nstant during closed anesthesia, which was much high(Jr than those in group C and M,. The tail gas of Capnomac Ultima MRGM contained less oxygen than its sample gas drawn fr0m circuit system simuItaneously.