In this paper,a lifted Haar transform(LHT)image compression optical chip has been researched to achieve rapid image compression.The chip comprises 32 same image compression optical circuits,and each circuit contains a...In this paper,a lifted Haar transform(LHT)image compression optical chip has been researched to achieve rapid image compression.The chip comprises 32 same image compression optical circuits,and each circuit contains a 2×2 multimode interference(MMI)coupler and aπ/2 delay line phase shifter as the key components.The chip uses highly borosilicate glass as the substrate,Su8 negative photoresist as the core layer,and air as the cladding layer.Its horizontal and longitudinal dimensions are 8011μm×10000μm.Simulation results present that the designed optical circuit has a coupling ratio(CR)of 0:100 and an insertion loss(IL)of 0.001548 d B.Then the chip is fabricated by femtosecond laser and testing results illustrate that the chip has a CR of 6:94 and an IL of 0.518 d B.So,the prepared chip possesses good image compression performance.展开更多
Rapid detection of foodborne pathogens is crucial to prevent the outbreaks of foodborne diseases.In this work,we proposed a novel microfluidic biosensor based on magnetorheological elastomer(MRE)and smartphone.First,m...Rapid detection of foodborne pathogens is crucial to prevent the outbreaks of foodborne diseases.In this work,we proposed a novel microfluidic biosensor based on magnetorheological elastomer(MRE)and smartphone.First,micropump and microvalves were constructed by deforming the MRE under magnetic actuation and integrated into the microfluidic biosensor for fluidic control.Then,the micropump was used to deliver immune porous gold@platinum nanocatalysts(Au@PtNCs),bacterial sample,and immunomagnetic nanoparticles(MNPs)into a micromixer,where they were mixed,incubated and magnetically separated to obtain the Au@PtNC-bacteria-MNP complexes.After 3,3',5,5'-tetramethylbenzidine and hydrogen peroxide were injected and catalyzed by the Au@PtNCs,smartphone was used to measure the color of the catalysate for quantitative analysis of target bacteria.Under optimal conditions,this biosensor could detect Salmonella typhimurium quantitatively and automatically in 1 h with a linear detection range of 8.0×10^(1) CFU/mL to 8.0×10^(4) CFU/mL and a detection limit of 62 CFU/mL.The microfluidic biosensor was compact in size,simple to use,and efficient for detection,and might be used for in-field screening of foodborne pathogens to prevent food poisoning.展开更多
基金the Natural Science Foundation of Hubei Province(No.2017CFB685)Hubei University of Technology"Advanced Manufacturing Technology and Equipment"Collaborative Innovation Center Open Research Fund(Nos.038/1201501 and 038/1201803)the College-level Project of Hubei University of Technology(Nos.4201/01758,4201/01802,4201/01889,and 4128/21025)。
文摘In this paper,a lifted Haar transform(LHT)image compression optical chip has been researched to achieve rapid image compression.The chip comprises 32 same image compression optical circuits,and each circuit contains a 2×2 multimode interference(MMI)coupler and aπ/2 delay line phase shifter as the key components.The chip uses highly borosilicate glass as the substrate,Su8 negative photoresist as the core layer,and air as the cladding layer.Its horizontal and longitudinal dimensions are 8011μm×10000μm.Simulation results present that the designed optical circuit has a coupling ratio(CR)of 0:100 and an insertion loss(IL)of 0.001548 d B.Then the chip is fabricated by femtosecond laser and testing results illustrate that the chip has a CR of 6:94 and an IL of 0.518 d B.So,the prepared chip possesses good image compression performance.
文摘Rapid detection of foodborne pathogens is crucial to prevent the outbreaks of foodborne diseases.In this work,we proposed a novel microfluidic biosensor based on magnetorheological elastomer(MRE)and smartphone.First,micropump and microvalves were constructed by deforming the MRE under magnetic actuation and integrated into the microfluidic biosensor for fluidic control.Then,the micropump was used to deliver immune porous gold@platinum nanocatalysts(Au@PtNCs),bacterial sample,and immunomagnetic nanoparticles(MNPs)into a micromixer,where they were mixed,incubated and magnetically separated to obtain the Au@PtNC-bacteria-MNP complexes.After 3,3',5,5'-tetramethylbenzidine and hydrogen peroxide were injected and catalyzed by the Au@PtNCs,smartphone was used to measure the color of the catalysate for quantitative analysis of target bacteria.Under optimal conditions,this biosensor could detect Salmonella typhimurium quantitatively and automatically in 1 h with a linear detection range of 8.0×10^(1) CFU/mL to 8.0×10^(4) CFU/mL and a detection limit of 62 CFU/mL.The microfluidic biosensor was compact in size,simple to use,and efficient for detection,and might be used for in-field screening of foodborne pathogens to prevent food poisoning.