Flow-injection Chemiluminescence Sensor for Hydrogen Peroxide with Immobilized Reagents
1
作者 Bao Xin LI Wei QIN Zhu Jun ZHANG (Department of Chemistry, Shaanxi Normal University, Xi’an 710062) 《Chinese Chemical Letters》 SCIE CAS CSCD 1998年第5期471-472,共2页
A novel chemiluminescence (CL) sensor for H2O2 combined with flow injection analysis is described in this paper. H2O2 is sensed by the CL reaction with luminol and Co2+ bleeding from the ion exchange column with immob... A novel chemiluminescence (CL) sensor for H2O2 combined with flow injection analysis is described in this paper. H2O2 is sensed by the CL reaction with luminol and Co2+ bleeding from the ion exchange column with immobilized reagents by hydrolysis. The calibration graph is linear and falls between the range of 4x10(-8) to 1x10(-5) mol/L. A complete analysis could be performed in 1 min. The system was reused for over 50 hours. 展开更多
关键词 chemiluminescence h2o2 analysis LUMINoL Co(II)