BACKGROUND Glaucoma is an irreversible optic neuropathy with the loss of visual field and decrease of vision.The variable clinical manifestations may result in differential diagnostic difficulties.The early screening ...BACKGROUND Glaucoma is an irreversible optic neuropathy with the loss of visual field and decrease of vision.The variable clinical manifestations may result in differential diagnostic difficulties.The early screening and diagnosis of glaucoma are currently experiencing a demand for anterior segment analysis tools that can gather more information with one short measurement.Therefore,we analyzed the agreement,difference,and correlation of chamber angle parameters such as angel opening distance at 500μm(AOD500)and trabeculo-iris space area at 500μm^2(TISA500)measured by anterior segment optical coherence tomography(ASOCT)and ultrasound biomicroscopy(UBM).AIM To compare the differences,correlation,and agreement in measuring AOD500 and TISA500 by AS-OCT and UBM.METHODS Both AS-OCT and UBM were performed to measure AOD500 and TISA500 in 45 subjects(72 eyes).All subjects without glaucoma were collected from October 2015 to August 2016 at the Ophthalmology Department of the Fourth Affiliated Hospital of China Medical University.Data of the two groups(AOD500 and TISA500)were compared by nonparametric tests.Pearson correlative analysis and Bland-Altman analysis were used to compare the correlation and agreement.RESULTS There were no significant differences between AS-OCT and UBM in measuring AOD500(P1=0.110,P2=0.633,P3=0.078,and P4=0.474)and TISA500(P1=0.584,P2=0.889,P3=0.297,and P4=0.550)of the four quadrants of the anterior chamber angle.There was a high correlation in measuring AOD500(r1=0.562,r2=0.671,r3=0.635,and r4=0.720;P<0.001)and TISA500(r1=0.584,r2=0.889,r3=0.297,and r4=0.550;P<0.001).There was a good agreement in measuring AOD500 and TISA500 by the two modalities.CONCLUSION There is a high correlation and agreement between AOD500 and TISA500 measurements by AS-OCT and UBM.They are interchangeable under some circumstances.AS-OCT proves to be a better early screening tool for glaucoma.展开更多
Since 2009,the Mine Safety and Health Administration(MSHA)has required mines to install refuge alternatives(RAs)in underground coal mines.One of the biggest concerns with occupied RAs is the possible severity of the r...Since 2009,the Mine Safety and Health Administration(MSHA)has required mines to install refuge alternatives(RAs)in underground coal mines.One of the biggest concerns with occupied RAs is the possible severity of the resulting thermal environment.In 30 CFR 7.504,the maximum allowable apparent temperature(AT)for an occupied RA is specified as 35℃(95°F).Manufacturers must conduct heat/humidity tests to demonstrate that their RAs meet the 35℃(95°F)AT limit.For these tests,heat input devices are used to input the metabolic heat of actual miners.A wide variety of test methods,sensors,and heat input devices could be used when conducting such tests.Since 2012,the National Institute for Occupational Safety and Health(NIOSH)has conducted over thirty 96-hour heat/humidity tests on four different RAs.This paper discusses the test equipment and procedures used during these investigations.This information is useful for RA manufacturers conducting RA heat/humidity tests,for other researchers investigating RA heat/humidity buildup,and for those who need to assess the thermal environment of any confined space where people may be trapped or are seeking refuge.展开更多
文摘BACKGROUND Glaucoma is an irreversible optic neuropathy with the loss of visual field and decrease of vision.The variable clinical manifestations may result in differential diagnostic difficulties.The early screening and diagnosis of glaucoma are currently experiencing a demand for anterior segment analysis tools that can gather more information with one short measurement.Therefore,we analyzed the agreement,difference,and correlation of chamber angle parameters such as angel opening distance at 500μm(AOD500)and trabeculo-iris space area at 500μm^2(TISA500)measured by anterior segment optical coherence tomography(ASOCT)and ultrasound biomicroscopy(UBM).AIM To compare the differences,correlation,and agreement in measuring AOD500 and TISA500 by AS-OCT and UBM.METHODS Both AS-OCT and UBM were performed to measure AOD500 and TISA500 in 45 subjects(72 eyes).All subjects without glaucoma were collected from October 2015 to August 2016 at the Ophthalmology Department of the Fourth Affiliated Hospital of China Medical University.Data of the two groups(AOD500 and TISA500)were compared by nonparametric tests.Pearson correlative analysis and Bland-Altman analysis were used to compare the correlation and agreement.RESULTS There were no significant differences between AS-OCT and UBM in measuring AOD500(P1=0.110,P2=0.633,P3=0.078,and P4=0.474)and TISA500(P1=0.584,P2=0.889,P3=0.297,and P4=0.550)of the four quadrants of the anterior chamber angle.There was a high correlation in measuring AOD500(r1=0.562,r2=0.671,r3=0.635,and r4=0.720;P<0.001)and TISA500(r1=0.584,r2=0.889,r3=0.297,and r4=0.550;P<0.001).There was a good agreement in measuring AOD500 and TISA500 by the two modalities.CONCLUSION There is a high correlation and agreement between AOD500 and TISA500 measurements by AS-OCT and UBM.They are interchangeable under some circumstances.AS-OCT proves to be a better early screening tool for glaucoma.
文摘Since 2009,the Mine Safety and Health Administration(MSHA)has required mines to install refuge alternatives(RAs)in underground coal mines.One of the biggest concerns with occupied RAs is the possible severity of the resulting thermal environment.In 30 CFR 7.504,the maximum allowable apparent temperature(AT)for an occupied RA is specified as 35℃(95°F).Manufacturers must conduct heat/humidity tests to demonstrate that their RAs meet the 35℃(95°F)AT limit.For these tests,heat input devices are used to input the metabolic heat of actual miners.A wide variety of test methods,sensors,and heat input devices could be used when conducting such tests.Since 2012,the National Institute for Occupational Safety and Health(NIOSH)has conducted over thirty 96-hour heat/humidity tests on four different RAs.This paper discusses the test equipment and procedures used during these investigations.This information is useful for RA manufacturers conducting RA heat/humidity tests,for other researchers investigating RA heat/humidity buildup,and for those who need to assess the thermal environment of any confined space where people may be trapped or are seeking refuge.