RF cold test of a novel C-band cavity beam position monitor (PBM) to be used in the SDUVFEL Test Facility is described. The test results are presented and some characteristics discussed. The main parameters obtained...RF cold test of a novel C-band cavity beam position monitor (PBM) to be used in the SDUVFEL Test Facility is described. The test results are presented and some characteristics discussed. The main parameters obtained are in reasonable agreement with the analytical estimations. Effective suppression of the common mode has been demonstrated. The position sensitivity over the test region of μ0.5 mm is about -21.58 dB/10 μm for the TM110 mode and is linear in the central region of the BPM cavity.展开更多
基金Supported by the National Key R&D Program of China(2021YFA0715500)National Natural Science Foundation of China(NSFC)(12227901)Chinese Academy of Sciences President’s International Fellowship Initiative(2021PT0007)。
基金Development Plan of the State Key Fundamental Research(2002CB713600)
文摘RF cold test of a novel C-band cavity beam position monitor (PBM) to be used in the SDUVFEL Test Facility is described. The test results are presented and some characteristics discussed. The main parameters obtained are in reasonable agreement with the analytical estimations. Effective suppression of the common mode has been demonstrated. The position sensitivity over the test region of μ0.5 mm is about -21.58 dB/10 μm for the TM110 mode and is linear in the central region of the BPM cavity.