竹材宏观自仿生纤维束的拉伸性能分析 被引量:1
1
作者 关明杰 崔海星 +2 位作者 孙敏洋 蔡智勇 朱一辛 《林业科技开发》 北大核心 2012年第5期31-34,共4页
对几种不同仿生螺旋结构竹纤维束的纵向拉伸性能进行测试分析,结果表明:平行均布、单螺旋、双螺旋A、双螺旋B型竹纤维束的拉伸强度分别为11.5、51.7、52.2和56.1 MPa;螺旋结构能够消除纤维束中的强度薄弱点,改善纤维束中各根纤维的结合... 对几种不同仿生螺旋结构竹纤维束的纵向拉伸性能进行测试分析,结果表明:平行均布、单螺旋、双螺旋A、双螺旋B型竹纤维束的拉伸强度分别为11.5、51.7、52.2和56.1 MPa;螺旋结构能够消除纤维束中的强度薄弱点,改善纤维束中各根纤维的结合,同时纤维束各层螺旋角的逐渐变化也有利于拉伸强度的提高。单螺旋、双螺旋A、双螺旋B型竹纤维束的拉伸弹性模量分别为9 659、5 265和4 291 MPa,单螺旋竹纤维束的拉伸弹性模量优于双螺旋竹纤维束。宏观仿生螺旋结构提高了竹束的拉伸强度,却降低了弹性模量。 展开更多
关键词 仿生螺旋 竹纤维束 拉伸强度 拉伸弹性模量
下载PDF
Leakage and Stiffness Characteristics of Bionic Cluster Spiral Groove Dry Gas Seal 被引量:3
2
作者 Jin-Bo Jiang Xu-Dong Peng +1 位作者 Ji-Yun Li Yuan Chen 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2018年第2期148-158,共11页
Spiral groove dry gas seal(S?DGS), the most widely used DGS in the world, encounters the problem of high leakage rate and inferior film stability when used in high?speed machinery equipment, which could not be well so... Spiral groove dry gas seal(S?DGS), the most widely used DGS in the world, encounters the problem of high leakage rate and inferior film stability when used in high?speed machinery equipment, which could not be well solved by optimization of geometrical parameters and molded line of spiral groove. A new type of bionic cluster spiral groove DGS(CS?DGS) is proved to have superior film stability than S?DGS at the condition of high?speed and low?pressure numerically. A bionic CS?DGS is experimentally investigated and compared with common S?DGS in order to provide evidence for theoretical study. The film thickness and leakage rate of both bionic spiral groove and common spiral groove DGS are measured and compared with each other and with theoretical values under different closing force at the condition of static pressure, high?speed and low?pressure, and the film stiffness and stiffness?leakage ratio of these two face seals are derived by the relationship between closing force and film thickness at the steady state. Experimental results agree well with the theory that the leakage and stiffness of bionic CS?DGS are superior to that of common S?DGS under the condition of high?speed and low?pressure, with the decreasing amplitude of 20% to 40% and the growth amplitude of 20%, respectively. The opening performance and stiffness characteristics of bionic CS?DGS are inferior to that of common S?DGS when rotation speed equals to 0 r/min. The proposed research provides a new method to measure the axis film stiffness of DGS, and validates the superior performance of bionic CS?DGS at the condition of high?speed and low?pressure experimentally. 展开更多
关键词 bionic cluster spiral groove Film stiffness Dry gas seal Leakage rate
下载PDF