In this study, we focused on the effect of the underwater explosion parameters of multi-point array explosion. The shock wave and bubble parameters of aggregate charge, two charges, and four charges were measured thro...In this study, we focused on the effect of the underwater explosion parameters of multi-point array explosion. The shock wave and bubble parameters of aggregate charge, two charges, and four charges were measured through an underwater explosion test, and their influence on the explosion power field of charge quantity and array distance was analyzed. Results show that the multi-shock wave collision of array explosion can be approximated to a linear superposition, and the interaction of delayed shock wave can be deemed as the increase of the shock wave baseline. Shock wave focusing and delayed superposition increase the shock wave peak pressure. Compared with the aggregate charge, the greater the number of array explosion points is, the higher the impulse and the gain of the bubble peak pressure are. At the same array distance, the smaller the charge quantity is, the higher the bubble impulse will be. At the same charge quantity, the smaller the array distance is, the higher the bubble impulse will be. The bubble period decreases gradually with the increase of the charge quantity, but the test orientation has little effect on the bubble period.展开更多
To objectively obtain the three-dimensional coordinates of the projectile fuze proximity explosion when projectile intersects the head of missile target, we propose a dynamic seven photoelectric detection screen test ...To objectively obtain the three-dimensional coordinates of the projectile fuze proximity explosion when projectile intersects the head of missile target, we propose a dynamic seven photoelectric detection screen test method, which is made up of six plane detection screens and a flash photoelectric dynamic detection screen. The three-dimensional coordinates calculation model of the projectile proximity explosion position based on seven plane detection screens with dynamic characteristics is established.According to the relation of the dynamic seven photoelectric detection screen planes and the time values,the analytical function of the projectile proximity explosion position parameters under non-linear motion is derived. The projectile signal filtering method based on discrete wavelet transform is explored in this work. Additionally, the projectile signal recognition algorithm using an improved particle swarm is proposed. Based on the characteristics of the time duration and the signal peak error for the projectile passing through the detection screen, the signals attribution of the same projectile passing through six detection screens are analyzed for obtaining precise time values of the same projectile passing through the detection screens. On the basis of the projectile fuze proximity explosion test, the linear motion model and the proposed non-linear motion model are used to calculate and compare the same group of projectiles proximity explosion position parameters. The comparison of test results verifies that the proposed test method and calculation model in this work accurately obtain the actual projectile proximity explosion position parameters.展开更多
文摘In this study, we focused on the effect of the underwater explosion parameters of multi-point array explosion. The shock wave and bubble parameters of aggregate charge, two charges, and four charges were measured through an underwater explosion test, and their influence on the explosion power field of charge quantity and array distance was analyzed. Results show that the multi-shock wave collision of array explosion can be approximated to a linear superposition, and the interaction of delayed shock wave can be deemed as the increase of the shock wave baseline. Shock wave focusing and delayed superposition increase the shock wave peak pressure. Compared with the aggregate charge, the greater the number of array explosion points is, the higher the impulse and the gain of the bubble peak pressure are. At the same array distance, the smaller the charge quantity is, the higher the bubble impulse will be. At the same charge quantity, the smaller the array distance is, the higher the bubble impulse will be. The bubble period decreases gradually with the increase of the charge quantity, but the test orientation has little effect on the bubble period.
基金supported by Project of the National Natural Science Foundation of China (No.62073256, 61773305)the Key Science and Technology Program of Shaanxi Province (No.2020GY-125)Xi’an Science and Technology Innovation talent service enterprise project (No.2020KJRC0041)。
文摘To objectively obtain the three-dimensional coordinates of the projectile fuze proximity explosion when projectile intersects the head of missile target, we propose a dynamic seven photoelectric detection screen test method, which is made up of six plane detection screens and a flash photoelectric dynamic detection screen. The three-dimensional coordinates calculation model of the projectile proximity explosion position based on seven plane detection screens with dynamic characteristics is established.According to the relation of the dynamic seven photoelectric detection screen planes and the time values,the analytical function of the projectile proximity explosion position parameters under non-linear motion is derived. The projectile signal filtering method based on discrete wavelet transform is explored in this work. Additionally, the projectile signal recognition algorithm using an improved particle swarm is proposed. Based on the characteristics of the time duration and the signal peak error for the projectile passing through the detection screen, the signals attribution of the same projectile passing through six detection screens are analyzed for obtaining precise time values of the same projectile passing through the detection screens. On the basis of the projectile fuze proximity explosion test, the linear motion model and the proposed non-linear motion model are used to calculate and compare the same group of projectiles proximity explosion position parameters. The comparison of test results verifies that the proposed test method and calculation model in this work accurately obtain the actual projectile proximity explosion position parameters.