Buck Converter Current Measurement Using Differential Amplifier
1
作者 P.Rajeswari V.Manikandan 《Intelligent Automation & Soft Computing》 SCIE 2023年第2期1387-1402,共16页
The accuracy of the measured current is a preeminent parameter for Current Control based Power Converter applications to ensure genuine operation of the designed converter.The current measurement accuracy can be affec... The accuracy of the measured current is a preeminent parameter for Current Control based Power Converter applications to ensure genuine operation of the designed converter.The current measurement accuracy can be affected by several parameters which includes the type of technology used,components used for the selected technology,aging,usage,operating and environmental conditions.The effect of gain resistors and their manufacturing tolerances on differential amplifier-based buck converter current measurement is investigated in this work.The analysis mainly focused on the output voltage variation and its accuracy with respect to the change in gain resistance tolerances.The gain resistors with 5%,1%,0.5%and 0.1%manufacturing tolerances taken for the worst-case analysis and the calculated performance results are compared and verified with the simula-tion results.The Operational amplifiers(Op-Amp)for high frequency power con-verter applications must operate in a high frequency noise environment and the intended current measuring system must manage common mode noise distur-bances paired with the signal to be measured.Based on the Common Mode Rejec-tion Ratio(CMRR)the common mode voltages and noise signals will effectively getfiltered out.Lesser CMRR results in lower common mode signal rejection,resulting in poor precision and noise rejection.In differential amplifiers,the CMRR predominantly depends on gain resistors.So,the variations in Common Mode Rejection Ratio due to gain resistor tolerances also analyzed and compared with the output voltage variations.Besides the effects of resistor tolerances,this paper also examines the effect of Op-Amp offset voltage on output accuracy spe-cifically for low magnitude input currents.The obtained results from this analysis clearly shows that the gain resistors with 0.1%tolerance gives maximum accuracy with improved CMRR and accuracy at low magnitude input currents will get well improved by using Op-Amps with Low Offset voltage specifications. 展开更多
关键词 Buck converter common mode rejection ratio common mode gain current sensing differential amplier differential mode gain shunt resistor
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部