The article investigates how to send perfect space-time codes with low feedback amount and symbol-by-symbol decoding for X channel using precoders. It is assumed that two users are introduced with two antennas and two...The article investigates how to send perfect space-time codes with low feedback amount and symbol-by-symbol decoding for X channel using precoders. It is assumed that two users are introduced with two antennas and two receivers. Each user employs a rate-2 space-time block code and follows certain rule when sending codewords. The multi-user interference is eliminated by pre-coding at the transmitter and linear processing at the receiver. Compared with the existing scheme for the same scene, the proposed scheme greatly reduces feedback amount and improves the transmission efficiency, while keeping the same decoding complexity. Simulations demonstrate the validity of the proposed scheme.展开更多
The adsorption of plasma proteins onto biomaterials can be characterized by either the amount of adsorbed protein or the conformation of the adsorbed proteins. The adsorption characteristics of biomaterials are import...The adsorption of plasma proteins onto biomaterials can be characterized by either the amount of adsorbed protein or the conformation of the adsorbed proteins. The adsorption characteristics of biomaterials are important for hemocompatibility evaluation. In this investigation, the amount of adsorbed human fibrinogen (HFG) and the conformation of the adsorbed HFG on different surfaces were measured simultaneously using transmission FTIR. The surface materials included CaF 2, polymethyl methacrylate (PMMA), type II polyurethane made by Chengdu University of Science & Technology, pellethane 2363 55D and pellethane 2363 80A. The results indicate that both the amount of adsorbed protein and the conformation of the adsorbed protein can be measured simultaneously using a single transmission FTIR technique. The result also suggests that a single parameter, either the adsorbed amount or the conformation of the adsorbed HFG, can not provide complete information about the hemocompatibility of the biomaterials. 展开更多
基金supported by the National Natural Science Foundation of China (51174263)the Natural Science Foundation of Henan (132300410461)
文摘The article investigates how to send perfect space-time codes with low feedback amount and symbol-by-symbol decoding for X channel using precoders. It is assumed that two users are introduced with two antennas and two receivers. Each user employs a rate-2 space-time block code and follows certain rule when sending codewords. The multi-user interference is eliminated by pre-coding at the transmitter and linear processing at the receiver. Compared with the existing scheme for the same scene, the proposed scheme greatly reduces feedback amount and improves the transmission efficiency, while keeping the same decoding complexity. Simulations demonstrate the validity of the proposed scheme.
文摘The adsorption of plasma proteins onto biomaterials can be characterized by either the amount of adsorbed protein or the conformation of the adsorbed proteins. The adsorption characteristics of biomaterials are important for hemocompatibility evaluation. In this investigation, the amount of adsorbed human fibrinogen (HFG) and the conformation of the adsorbed HFG on different surfaces were measured simultaneously using transmission FTIR. The surface materials included CaF 2, polymethyl methacrylate (PMMA), type II polyurethane made by Chengdu University of Science & Technology, pellethane 2363 55D and pellethane 2363 80A. The results indicate that both the amount of adsorbed protein and the conformation of the adsorbed protein can be measured simultaneously using a single transmission FTIR technique. The result also suggests that a single parameter, either the adsorbed amount or the conformation of the adsorbed HFG, can not provide complete information about the hemocompatibility of the biomaterials.