The effect of an alternating external magnetic field on spin tunneling is studied for a single axial magnetocrystalline anisotropy model. The model for spin half is solved and the result shows that an alternating fiel...The effect of an alternating external magnetic field on spin tunneling is studied for a single axial magnetocrystalline anisotropy model. The model for spin half is solved and the result shows that an alternating field can suppress magnetic tunneling. The probability of tunneling for large spin is obtained with the help of quantum mechanical perturbation theory.展开更多
A 2-D mathematical model is developed in order to simulate a parametric electromagnetic instability oscillation process of a liquid metal droplet under the action of low frequency magnetic field. The Arbitrary Lagrang...A 2-D mathematical model is developed in order to simulate a parametric electromagnetic instability oscillation process of a liquid metal droplet under the action of low frequency magnetic field. The Arbitrary Lagrangian-Eulerian (ALE) method and weak form constraint boundary condition are introduced in this model for implementation of the surface tension and electromagnetic force on liquid droplet free surface. The results of the numerical calculations indicate the appearance of various regimes of oscillation. It is found that according to the magnetic field frequency various types of oscillation modes may be found. The oscillation is originated from an instability phenomenon. The stability diagram of liquid metal droplet in the parameter space of magnetic frequency and magnetic flux density is determined numerically. The diagram is very similar to that found in the so-called parametric instability.展开更多
The effects of alternating magnetic field on the corrosion morphologies, corrosion rate, and corrosion products of copper in 3.5% NaCl solution, sea water, and magnetized sea water were investigated using electrochemi...The effects of alternating magnetic field on the corrosion morphologies, corrosion rate, and corrosion products of copper in 3.5% NaCl solution, sea water, and magnetized sea water were investigated using electrochemical test, scanning electron microscopy/energy dispersive analysis system of X-ray (SEM/EDAX), and X-ray diffraction (XRD). The results show that the corrosion rate of copper in magnetized sea water is minimal. Moreover, the surface of the specimen in magnetized sea water is uniform and compact as compared with those in 3.5% NaCl solution and sea water. The corrosion products of copper in magnetized sea water are mainly Cu2O and CuCl2. However, the corrosion products in sea water are CuCl, Cu2Cl(OH)3, and FeCl3-6H2O. The electrochemical corrosion mechanisms of copper in the three media were also discussed.展开更多
文摘The effect of an alternating external magnetic field on spin tunneling is studied for a single axial magnetocrystalline anisotropy model. The model for spin half is solved and the result shows that an alternating field can suppress magnetic tunneling. The probability of tunneling for large spin is obtained with the help of quantum mechanical perturbation theory.
基金supported by the National Natural Science Foundation of China(Grant Nos.51274137,10872123)supported by the China Scholarship Council and Région Rhne-Alpes (France) for supporting Lei's visiting in Grenoble
文摘A 2-D mathematical model is developed in order to simulate a parametric electromagnetic instability oscillation process of a liquid metal droplet under the action of low frequency magnetic field. The Arbitrary Lagrangian-Eulerian (ALE) method and weak form constraint boundary condition are introduced in this model for implementation of the surface tension and electromagnetic force on liquid droplet free surface. The results of the numerical calculations indicate the appearance of various regimes of oscillation. It is found that according to the magnetic field frequency various types of oscillation modes may be found. The oscillation is originated from an instability phenomenon. The stability diagram of liquid metal droplet in the parameter space of magnetic frequency and magnetic flux density is determined numerically. The diagram is very similar to that found in the so-called parametric instability.
文摘The effects of alternating magnetic field on the corrosion morphologies, corrosion rate, and corrosion products of copper in 3.5% NaCl solution, sea water, and magnetized sea water were investigated using electrochemical test, scanning electron microscopy/energy dispersive analysis system of X-ray (SEM/EDAX), and X-ray diffraction (XRD). The results show that the corrosion rate of copper in magnetized sea water is minimal. Moreover, the surface of the specimen in magnetized sea water is uniform and compact as compared with those in 3.5% NaCl solution and sea water. The corrosion products of copper in magnetized sea water are mainly Cu2O and CuCl2. However, the corrosion products in sea water are CuCl, Cu2Cl(OH)3, and FeCl3-6H2O. The electrochemical corrosion mechanisms of copper in the three media were also discussed.