Transient electromagnetic method (TEM),as a non-seismic geophysical exploration mainstream electromagnetic method,is widely used in oil,gas,mineral and other underground resources exploration areas. The coil sensor is...Transient electromagnetic method (TEM),as a non-seismic geophysical exploration mainstream electromagnetic method,is widely used in oil,gas,mineral and other underground resources exploration areas. The coil sensor is generally used to collect data. In view of the problems of incomplete information of the abnormal body and the data loss in the existing TEM single-component coil sensor,a three-component TEM coil sensor is designed. By analyzing the relationship between sensor sensitivity and coil structure parameters,the coil structure and turns are designed. By analyzing the frequency response characteristics of the TEM magnetic field sensor,the signal distortion is reduced by using the under-damped matching mode. By analyzing the distribution of various noise sources of the magnetic sensor,the appropriate amplifier is selected to reduce the background noise. Finally,a three-component TEM induction magnetic field sensor is designed. The weight of the sensor is controlled at 3.2 kg and the working frequency is 10 mHz-10 kHz. The background noises of X and Y components probably keep in 1.5×10^-8 V/ Hz and sensitivities are 8.4 and 9.8 nT/s,respectively,the background noise of vertical component is 2.1× 10^-7 V/ Hz and sensitivity is 18.5 nT/s. Compared with the existing single-component TEM receiving magnetic field sensor,the designed sensor realizes the signal acquisition of three components. Without too much increase in volume and total weight,it improves the sensitivity of the sensor and reduces the background noise,thus the signal-to-noise ratio (SNR) of the signal is improved.展开更多
Magnetometric resistivity(MMR)method is a new way to detect dam leakage.The coil sensor is generally used to collect data in geophysical exploration methods.Given the characteristics of accurate vector data requiremen...Magnetometric resistivity(MMR)method is a new way to detect dam leakage.The coil sensor is generally used to collect data in geophysical exploration methods.Given the characteristics of accurate vector data requirements and high sensitivity requirement,a three-component MMR air-core coil sensor is designed.Through the analysis of sensor sensitivity and coil structure parameters,the coil structure and turn number are designed.By analyzing the noise source of the sensor,a suitable amplifier is selected to reduce the background noise of the system.Through the analysis of the three-component non-orthogonal angles,the parameters of the non-orthogonal angles of the coils are corrected.Finally,a three-component MMR induction magnetic field sensor is designed.The volume of the sensor is controlled at 0.027 m 3.The background noise of X、Y and Z are 5.030435 nV/Hz@380 Hz and magnetic field sensitivities are 0.18995 pT/Hz@380 Hz.The three channels have good consistency,and the three-component nonorthogonal angles correction error of three components is controlled within 0.2%.展开更多
The traditional integer order PID controller manipulates the air-conditioning fan coil unit(FCU)that offers cooliug and heatins loads to each air-conditioning room in summer and winter,respectivelv.In order to maintai...The traditional integer order PID controller manipulates the air-conditioning fan coil unit(FCU)that offers cooliug and heatins loads to each air-conditioning room in summer and winter,respectivelv.In order to maintain a steady indoor temperature in summer and winter,the control quality cannot meet the related requirements of air-conditioning automation,such as large overshoot,large steady state error.long regulating time,etc.In view of these factors,this paper develops a fractional order PID controller to deal with such problem associated with FCU.Then,by varving mutation factor and crossover rate of basic differential evolution algorithmadaptivelv,a modified differential evolution algorithm(MDEA)is designed to tune the satisfactory values of five parameters of indoor temperature fractional order PID controller.This fractional order PID coutrol system is configured and the corresponding mumerical simulation is conducted by means of MATLAB software.The results indicate that the proposed fractional order PID control svstem and MDEA are reliable and the related control performance indexes meet with the related requirements of comfortable air-conditioning design and control criteria.展开更多
In this paper,the performance analysis of recharging the borehole by means of exhaust-air energy is carried out.The results show that a vertical borehole used as heat source for a Ground Source Heat Pump(GSHP)can be r...In this paper,the performance analysis of recharging the borehole by means of exhaust-air energy is carried out.The results show that a vertical borehole used as heat source for a Ground Source Heat Pump(GSHP)can be recharged in high efficiency.With equal heat transfer capabilities of exhaust-air coil and borehole collector,the system provides a maximum overall efficiency.However,due to ground infinite capacity,the optimum brine flow rate is different from conventional two-exchanger system.The recharging system provides two peak overall efficiencies when the capacity ratio Cr=5 for laminar flow and Cr=15 for turbulent flow respectively.The overall efficiency is independent of exhaust-air temperature and undisturbed ground temperature,although the fluid properties depend on temperature.In practical system lower ethyl percentage brine should be chosen if the freezing point meets the system request,which can provide a higher overall efficiency.展开更多
文摘Transient electromagnetic method (TEM),as a non-seismic geophysical exploration mainstream electromagnetic method,is widely used in oil,gas,mineral and other underground resources exploration areas. The coil sensor is generally used to collect data. In view of the problems of incomplete information of the abnormal body and the data loss in the existing TEM single-component coil sensor,a three-component TEM coil sensor is designed. By analyzing the relationship between sensor sensitivity and coil structure parameters,the coil structure and turns are designed. By analyzing the frequency response characteristics of the TEM magnetic field sensor,the signal distortion is reduced by using the under-damped matching mode. By analyzing the distribution of various noise sources of the magnetic sensor,the appropriate amplifier is selected to reduce the background noise. Finally,a three-component TEM induction magnetic field sensor is designed. The weight of the sensor is controlled at 3.2 kg and the working frequency is 10 mHz-10 kHz. The background noises of X and Y components probably keep in 1.5×10^-8 V/ Hz and sensitivities are 8.4 and 9.8 nT/s,respectively,the background noise of vertical component is 2.1× 10^-7 V/ Hz and sensitivity is 18.5 nT/s. Compared with the existing single-component TEM receiving magnetic field sensor,the designed sensor realizes the signal acquisition of three components. Without too much increase in volume and total weight,it improves the sensitivity of the sensor and reduces the background noise,thus the signal-to-noise ratio (SNR) of the signal is improved.
文摘Magnetometric resistivity(MMR)method is a new way to detect dam leakage.The coil sensor is generally used to collect data in geophysical exploration methods.Given the characteristics of accurate vector data requirements and high sensitivity requirement,a three-component MMR air-core coil sensor is designed.Through the analysis of sensor sensitivity and coil structure parameters,the coil structure and turn number are designed.By analyzing the noise source of the sensor,a suitable amplifier is selected to reduce the background noise of the system.Through the analysis of the three-component non-orthogonal angles,the parameters of the non-orthogonal angles of the coils are corrected.Finally,a three-component MMR induction magnetic field sensor is designed.The volume of the sensor is controlled at 0.027 m 3.The background noise of X、Y and Z are 5.030435 nV/Hz@380 Hz and magnetic field sensitivities are 0.18995 pT/Hz@380 Hz.The three channels have good consistency,and the three-component nonorthogonal angles correction error of three components is controlled within 0.2%.
基金the National Natural Science Foundation of China(Nos.61364004 and 51808275)the Chinese Scholars to Study Overseas Sponsored by ChinaScholarship Council Foundation(No.201408625045)+1 种基金the Doctoral Research Funds of Lanzhou University of Technology(No.04-237)the Alumni Foundation Civil Engineering 77,Lanzhou University of Technology(No.TM-QK1301)。
文摘The traditional integer order PID controller manipulates the air-conditioning fan coil unit(FCU)that offers cooliug and heatins loads to each air-conditioning room in summer and winter,respectivelv.In order to maintain a steady indoor temperature in summer and winter,the control quality cannot meet the related requirements of air-conditioning automation,such as large overshoot,large steady state error.long regulating time,etc.In view of these factors,this paper develops a fractional order PID controller to deal with such problem associated with FCU.Then,by varving mutation factor and crossover rate of basic differential evolution algorithmadaptivelv,a modified differential evolution algorithm(MDEA)is designed to tune the satisfactory values of five parameters of indoor temperature fractional order PID controller.This fractional order PID coutrol system is configured and the corresponding mumerical simulation is conducted by means of MATLAB software.The results indicate that the proposed fractional order PID control svstem and MDEA are reliable and the related control performance indexes meet with the related requirements of comfortable air-conditioning design and control criteria.
文摘In this paper,the performance analysis of recharging the borehole by means of exhaust-air energy is carried out.The results show that a vertical borehole used as heat source for a Ground Source Heat Pump(GSHP)can be recharged in high efficiency.With equal heat transfer capabilities of exhaust-air coil and borehole collector,the system provides a maximum overall efficiency.However,due to ground infinite capacity,the optimum brine flow rate is different from conventional two-exchanger system.The recharging system provides two peak overall efficiencies when the capacity ratio Cr=5 for laminar flow and Cr=15 for turbulent flow respectively.The overall efficiency is independent of exhaust-air temperature and undisturbed ground temperature,although the fluid properties depend on temperature.In practical system lower ethyl percentage brine should be chosen if the freezing point meets the system request,which can provide a higher overall efficiency.