In this article, a nonlinear model of an underactuated six degrees of freedom (6 DOF) quadrotor helicopter is derived on the basis of the Newton-Euler formalism. The derivation comprises determining equations of the...In this article, a nonlinear model of an underactuated six degrees of freedom (6 DOF) quadrotor helicopter is derived on the basis of the Newton-Euler formalism. The derivation comprises determining equations of the motion of the quadrotor in three dimensions and approximating the actuation forces through the modeling of aerodynamic coefficients and electric motor dynamics. The derived model composed of translational and rotational subsystems is dynamically unstable, so a sequential nonlinear control strategy is used. The control strategy includes feedback linearization coupled with a PD controller for the translational subsystem and a backstepping-based PID nonlinear controller for the rotational subsystem of the quadrotor. The performances of the nonlinear control method are evaluated by nonlinear simulation and the results demonstrate the effectiveness of the proposed control strategy for the quadrotor helicopter in quasi-stationary flights.展开更多
When developing a humanoid myo-control hand,not only the mechanical structure should be considered to afford a high dexterity,but also the myoelectric (electromyography,EMG) control capability should be taken into acc...When developing a humanoid myo-control hand,not only the mechanical structure should be considered to afford a high dexterity,but also the myoelectric (electromyography,EMG) control capability should be taken into account to fully accomplish the actuation tasks.This paper presents a novel humanoid robotic myocontrol hand (AR hand Ⅲ) which adopted an underac- tuated mechanism and a forearm myocontrol EMG method.The AR hand Ⅲ has five fingers and 15 joints,and actuated by three embedded motors.Underactuation can be found within each finger and between the rest three fingers (the middle finger,the ring finger and the little finger) when the hand is grasping objects.For the EMG control,two specific methods are proposed:the three-fingered hand gesture configuration of the AR hand Ⅲ and a pattern classification method of EMG signals based on a statistical learning algorithm-Support Vector Machine (SVM).Eighteen active hand gestures of a testee are recognized ef- fectively,which can be directly mapped into the motions of AR hand Ⅲ.An on-line EMG control scheme is established based on two different decision functions:one is for the discrimination between the idle and active modes,the other is for the recog- nition of the active modes.As a result,the AR hand Ⅲ can swiftly follow the gesture instructions of the testee with a time delay less than 100 ms.展开更多
基金Higher Education Commission,Government of Paki-stan(1-3/PM-OVER/China/2005)
文摘In this article, a nonlinear model of an underactuated six degrees of freedom (6 DOF) quadrotor helicopter is derived on the basis of the Newton-Euler formalism. The derivation comprises determining equations of the motion of the quadrotor in three dimensions and approximating the actuation forces through the modeling of aerodynamic coefficients and electric motor dynamics. The derived model composed of translational and rotational subsystems is dynamically unstable, so a sequential nonlinear control strategy is used. The control strategy includes feedback linearization coupled with a PD controller for the translational subsystem and a backstepping-based PID nonlinear controller for the rotational subsystem of the quadrotor. The performances of the nonlinear control method are evaluated by nonlinear simulation and the results demonstrate the effectiveness of the proposed control strategy for the quadrotor helicopter in quasi-stationary flights.
基金supported by the National Natural Science Foundation (Grant No. 50435040 and 60675045)the National High Technology Research and Development Program (Grant No. 2006AA04Z228)the "111 Project" of China (No. B07018).
文摘When developing a humanoid myo-control hand,not only the mechanical structure should be considered to afford a high dexterity,but also the myoelectric (electromyography,EMG) control capability should be taken into account to fully accomplish the actuation tasks.This paper presents a novel humanoid robotic myocontrol hand (AR hand Ⅲ) which adopted an underac- tuated mechanism and a forearm myocontrol EMG method.The AR hand Ⅲ has five fingers and 15 joints,and actuated by three embedded motors.Underactuation can be found within each finger and between the rest three fingers (the middle finger,the ring finger and the little finger) when the hand is grasping objects.For the EMG control,two specific methods are proposed:the three-fingered hand gesture configuration of the AR hand Ⅲ and a pattern classification method of EMG signals based on a statistical learning algorithm-Support Vector Machine (SVM).Eighteen active hand gestures of a testee are recognized ef- fectively,which can be directly mapped into the motions of AR hand Ⅲ.An on-line EMG control scheme is established based on two different decision functions:one is for the discrimination between the idle and active modes,the other is for the recog- nition of the active modes.As a result,the AR hand Ⅲ can swiftly follow the gesture instructions of the testee with a time delay less than 100 ms.