Computational Fluid Dynamics (CFD) simulations of airflow through a retention head residential oil burner were carried out to study the velocity field near and around the fuel spray. The simulations revealed (as expec...Computational Fluid Dynamics (CFD) simulations of airflow through a retention head residential oil burner were carried out to study the velocity field near and around the fuel spray. The simulations revealed (as expected, based on some previous experimental measurements) the velocity flow field to be far from axisymmetric. Moreover, the center of the swirling airflow was found to be at some radial distance away from the physical centerline of the flame tube. Since it was suspected that the two electrodes just upstream of the retention ring of the burner might be responsible for this flow distortion, additional CFD simulations were then carried out for the cases of no electrodes and 4-electrodes. The results clearly show that all flow distortions (velocity deviations from axisymmetric value) vanish when no electrodes are present and that the flow distortions are reduced by a factor of 2 when two additional dummy electrodes (for a total of 4 electrodes) are included in the burner design. Furthermore, for the 4-electrode case, the eccentricity of the swirling airflow is reduced by almost a factor of 3 as compared to the base design case of 2-electrodes.展开更多
To examine the working principle of vertical tube irrigation, variations in vertical tube emitter discharge and their causes were analyzed in the laboratory experiment. The effects of the pressure head, initial soil w...To examine the working principle of vertical tube irrigation, variations in vertical tube emitter discharge and their causes were analyzed in the laboratory experiment. The effects of the pressure head, initial soil water content, and tube diameter on the emitter discharge of the vertical tube were studied. The results show that quantitative relationship between the time and cumulative infiltration and emitter discharge of the vertical tube is obtained, and R 2 is more than 0.98. Emitter discharge exhibits a positive and negative correlation with the pressure head and soil water content, respectively. Tube dia- meter has a nonsignificant effect on the emitter discharge. Changes of the soil water content around the emitter water outlet are the main causes of emitter discharge variations. In the experiments, the range of vertical tube emitter discharge is 0.056-1.102 L/h. The emitter of vertical tube irrigation automatically adjusts the soil water content and maintains the root zone soil water content within an appropriate range, which achieves continuous irrigation, and further achieves the effect of water-saving.展开更多
文摘Computational Fluid Dynamics (CFD) simulations of airflow through a retention head residential oil burner were carried out to study the velocity field near and around the fuel spray. The simulations revealed (as expected, based on some previous experimental measurements) the velocity flow field to be far from axisymmetric. Moreover, the center of the swirling airflow was found to be at some radial distance away from the physical centerline of the flame tube. Since it was suspected that the two electrodes just upstream of the retention ring of the burner might be responsible for this flow distortion, additional CFD simulations were then carried out for the cases of no electrodes and 4-electrodes. The results clearly show that all flow distortions (velocity deviations from axisymmetric value) vanish when no electrodes are present and that the flow distortions are reduced by a factor of 2 when two additional dummy electrodes (for a total of 4 electrodes) are included in the burner design. Furthermore, for the 4-electrode case, the eccentricity of the swirling airflow is reduced by almost a factor of 3 as compared to the base design case of 2-electrodes.
基金National Natural Science Foundation of China (41571222)。
文摘To examine the working principle of vertical tube irrigation, variations in vertical tube emitter discharge and their causes were analyzed in the laboratory experiment. The effects of the pressure head, initial soil water content, and tube diameter on the emitter discharge of the vertical tube were studied. The results show that quantitative relationship between the time and cumulative infiltration and emitter discharge of the vertical tube is obtained, and R 2 is more than 0.98. Emitter discharge exhibits a positive and negative correlation with the pressure head and soil water content, respectively. Tube dia- meter has a nonsignificant effect on the emitter discharge. Changes of the soil water content around the emitter water outlet are the main causes of emitter discharge variations. In the experiments, the range of vertical tube emitter discharge is 0.056-1.102 L/h. The emitter of vertical tube irrigation automatically adjusts the soil water content and maintains the root zone soil water content within an appropriate range, which achieves continuous irrigation, and further achieves the effect of water-saving.