A new absorbent of nanometer-size TiO2 colloid for Cu(Ⅱ ) was studied in this work. The adsorption rate could reach above 99% when the pH values were at the range of 5-6. The adsorption balance time, adsorption cap...A new absorbent of nanometer-size TiO2 colloid for Cu(Ⅱ ) was studied in this work. The adsorption rate could reach above 99% when the pH values were at the range of 5-6. The adsorption balance time, adsorption capacities, and the eluent were investigated. A novel method of trace Cu( Ⅱ ) preconcentration and separation with nanometer-size titanium dioxide colloid and determination by flame atomic absorption spectrometry (FAAS) was advanced. The detection limit (3a) of the method was 1.15 μg · L^-1, and the relative standard deviation (R.S.D) was 1.53% (n=6). Environmental sample experiments were also conducted to test the feasibility of the method, and it came out that the recovery rates were between 95.9% and 97.8%.展开更多
A novel method of ultra-trace Cd(Ⅱ) preconcentration with nanometer-size TiO2 colloid and determination by graphite furnace atomic adsorption spectrometry(GFAAS) with slurry sampling was first advanced in this pa...A novel method of ultra-trace Cd(Ⅱ) preconcentration with nanometer-size TiO2 colloid and determination by graphite furnace atomic adsorption spectrometry(GFAAS) with slurry sampling was first advanced in this paper. The adsorption efficiency of nanometer-size TiO2 colloid for ultra-trace Cd(Ⅱ) could reach above 96% in a short time when the pH value was between 5 and 6. Other problems were also studied, such as adsorption capacity, nanometer-size TiO2 colloid dosage, effect of coexistent ions. The detection limit(3σ) and the relative standard deviation (R.S.D) of this method were 4.46.103 μg/L and 1.30%(n=7), respectively. The method was successfully applied to the analysis of environmental samples with recoveries between 93.8% and 96.4%.展开更多
基金Supported by the Natural Science Foundation of Hubei Province(2006ABA236)
文摘A new absorbent of nanometer-size TiO2 colloid for Cu(Ⅱ ) was studied in this work. The adsorption rate could reach above 99% when the pH values were at the range of 5-6. The adsorption balance time, adsorption capacities, and the eluent were investigated. A novel method of trace Cu( Ⅱ ) preconcentration and separation with nanometer-size titanium dioxide colloid and determination by flame atomic absorption spectrometry (FAAS) was advanced. The detection limit (3a) of the method was 1.15 μg · L^-1, and the relative standard deviation (R.S.D) was 1.53% (n=6). Environmental sample experiments were also conducted to test the feasibility of the method, and it came out that the recovery rates were between 95.9% and 97.8%.
文摘A novel method of ultra-trace Cd(Ⅱ) preconcentration with nanometer-size TiO2 colloid and determination by graphite furnace atomic adsorption spectrometry(GFAAS) with slurry sampling was first advanced in this paper. The adsorption efficiency of nanometer-size TiO2 colloid for ultra-trace Cd(Ⅱ) could reach above 96% in a short time when the pH value was between 5 and 6. Other problems were also studied, such as adsorption capacity, nanometer-size TiO2 colloid dosage, effect of coexistent ions. The detection limit(3σ) and the relative standard deviation (R.S.D) of this method were 4.46.103 μg/L and 1.30%(n=7), respectively. The method was successfully applied to the analysis of environmental samples with recoveries between 93.8% and 96.4%.