采用后期浸渍的方法合成了Ti负载硅基MCM-41,并利用XRD、FT-IR、29Si MAS NMR及N2吸附-脱附等表征手段和苯乙烯的催化氧化反应,系统研究了Ti负载对MCM-41结构和催化性能的影响。研究结果表明:Ti负载后MCM-41结构有序度下降,但仍具有良...采用后期浸渍的方法合成了Ti负载硅基MCM-41,并利用XRD、FT-IR、29Si MAS NMR及N2吸附-脱附等表征手段和苯乙烯的催化氧化反应,系统研究了Ti负载对MCM-41结构和催化性能的影响。研究结果表明:Ti负载后MCM-41结构有序度下降,但仍具有良好的有序结构。Ti进入MCM-41的骨架形成Ti-O-Si键,随着Ti负载量的增加,部分Ti以TiO2的形态存在。与Si-MCM-41相比,Ti负载后MCM-41的孔结构产生变化,比表面积减小,孔径分布变窄。当Ti负载到硅基MCM-41时,其具有明显的催化性能。展开更多
Bacterial colonization of orthopedic implants is one of the leading causes of failure and clinical complexities for load-bearing metallic implants. Topical or systemic administration of antibiotics may not offer the m...Bacterial colonization of orthopedic implants is one of the leading causes of failure and clinical complexities for load-bearing metallic implants. Topical or systemic administration of antibiotics may not offer the most efficient defense against colonization, especially in the case of secondary infection, leading to surgical removal of implants and in some cases even limbs. In this study, laser powder bed fusion was implemented to fabricate Ti3Al2V alloy by a 1:1 weight mixture of CpTi and Ti6Al4V powders. Ti-Tantalum(Ta)–Copper(Cu) alloys were further analyzed by the addition of Ta and Cu into the Ti3Al2V custom alloy. The biological,mechanical, and tribo-biocorrosion properties of Ti3Al2V alloy were evaluated. A 10 wt.% Ta(10Ta) and 3 wt.% Cu(3Cu) were added to the Ti3Al2V alloy to enhance biocompatibility and impart inherent bacterial resistance. Additively manufactured implants were investigated for resistance against Pseudomonas aeruginosa and Staphylococcus aureus strains of bacteria for up to 48 h. A 3 wt.% Cu addition to Ti3Al2V displayed improved antibacterial efficacy, i.e.78%–86% with respect to CpTi. Mechanical properties for Ti3Al2V–10Ta–3Cu alloy were evaluated, demonstrating excellent fatigue resistance, exceptional shear strength, and improved tribological and tribo-biocorrosion characteristics when compared to Ti6Al4V. In vivo studies using a rat distal femur model revealed improved early-stage osseointegration for alloys with10 wt.% Ta addition compared to CpTi and Ti6Al4V. The 3 wt.% Cu-added compositions displayed biocompatibility and no adverse infammatory response in vivo. Our results establish the Ti3Al2V–10Ta–3Cu alloy’s synergistic effect on improving both in vivo biocompatibility and microbial resistance for the next generation of load-bearing metallic implants.展开更多
With the rapid development of ocean technology, the deep-sea manned submersible is regarded as a high-tech equipment for the exploration and exploitation of ocean resources. The safety of manned cabin has a decisive e...With the rapid development of ocean technology, the deep-sea manned submersible is regarded as a high-tech equipment for the exploration and exploitation of ocean resources. The safety of manned cabin has a decisive effect on the whole system. Ti-6 Al-4 V with the superior strength-to-weight ratio and corrosion resistance has been used for the manned cabin. The manned cabin experiences loading spectrum with different maximum stresses and different dwell time during their service life. The load sequence effects on dwell fatigue crack growth behavior of Ti-6 Al-4 V under different dwell time are investigated experimentally in this paper. The experimental results show that the crack tip plastic zone is enlarged by the dwell time and the overload retardation zone increases with dwell time under the same overload rate. A dwell fatigue crack growth model is proposed by modifying the crack tip plastic zone under the loading history with combinations of the single overload and dwell time factors are included in the modified model. Based on the experimental data, the overload retardation zone and the crack growth rates of Ti-6 Al-4 V are predicted by the modified model. A reasonable model for the load sequence effect on the dwell fatigue crack growth rates of Ti-6 Al-4 V is verified.展开更多
Hetero-element doped lithium orthosilicates have been considered as advanced tritium breeders due to the superior performances.In this work,Li_(4)Si_(1-x)Ti_(x)O_(4) ceramics were prepared by proprietary hydrothermal ...Hetero-element doped lithium orthosilicates have been considered as advanced tritium breeders due to the superior performances.In this work,Li_(4)Si_(1-x)Ti_(x)O_(4) ceramics were prepared by proprietary hydrothermal process and multistage reactive sintering.The reaction mechanism of Li_(4)Si_(1-x)Ti_(x)O_(4) was put forward.XRD and SEM analyses indicate that insertion of Ti leads to lattice expansion,which promotes the grain growth and changes the fracture mode.The compressive tests show that the crush load increases almost four times by increasing x from 0 to 0.2.However,the thermal conductivity and ionic conductivity are the best when x=0.05 and x=0.1,respectively.Thermal cycling stability of Li_(4)Si_(1-x)Ti_(x)O_(4) pebbles was further appraised through investigating the changes of microstructure and crush load.After undergoing thermal cycling,the Li_(4)Si_(1-x)Ti_(x)O_(4) still show higher crush load compared with Li_(4)SiO_(4),despite Ti segregation in some samples.The x=0.05 sample exhibits excellent thermal cycling stability.In summary,proper amount of Ti doping can improve the crush load,thermal and ionic conductivity,and thermal cycling stability of Li_(4)SiO_(4).展开更多
文摘采用后期浸渍的方法合成了Ti负载硅基MCM-41,并利用XRD、FT-IR、29Si MAS NMR及N2吸附-脱附等表征手段和苯乙烯的催化氧化反应,系统研究了Ti负载对MCM-41结构和催化性能的影响。研究结果表明:Ti负载后MCM-41结构有序度下降,但仍具有良好的有序结构。Ti进入MCM-41的骨架形成Ti-O-Si键,随着Ti负载量的增加,部分Ti以TiO2的形态存在。与Si-MCM-41相比,Ti负载后MCM-41的孔结构产生变化,比表面积减小,孔径分布变窄。当Ti负载到硅基MCM-41时,其具有明显的催化性能。
基金supported by the National Institute of Arthritis and Musculoskeletal and Skin Diseases of the National Institutes of Health under Award Numbers R01 AR067306 and R01 AR078241。
文摘Bacterial colonization of orthopedic implants is one of the leading causes of failure and clinical complexities for load-bearing metallic implants. Topical or systemic administration of antibiotics may not offer the most efficient defense against colonization, especially in the case of secondary infection, leading to surgical removal of implants and in some cases even limbs. In this study, laser powder bed fusion was implemented to fabricate Ti3Al2V alloy by a 1:1 weight mixture of CpTi and Ti6Al4V powders. Ti-Tantalum(Ta)–Copper(Cu) alloys were further analyzed by the addition of Ta and Cu into the Ti3Al2V custom alloy. The biological,mechanical, and tribo-biocorrosion properties of Ti3Al2V alloy were evaluated. A 10 wt.% Ta(10Ta) and 3 wt.% Cu(3Cu) were added to the Ti3Al2V alloy to enhance biocompatibility and impart inherent bacterial resistance. Additively manufactured implants were investigated for resistance against Pseudomonas aeruginosa and Staphylococcus aureus strains of bacteria for up to 48 h. A 3 wt.% Cu addition to Ti3Al2V displayed improved antibacterial efficacy, i.e.78%–86% with respect to CpTi. Mechanical properties for Ti3Al2V–10Ta–3Cu alloy were evaluated, demonstrating excellent fatigue resistance, exceptional shear strength, and improved tribological and tribo-biocorrosion characteristics when compared to Ti6Al4V. In vivo studies using a rat distal femur model revealed improved early-stage osseointegration for alloys with10 wt.% Ta addition compared to CpTi and Ti6Al4V. The 3 wt.% Cu-added compositions displayed biocompatibility and no adverse infammatory response in vivo. Our results establish the Ti3Al2V–10Ta–3Cu alloy’s synergistic effect on improving both in vivo biocompatibility and microbial resistance for the next generation of load-bearing metallic implants.
基金financially supported by the National Natural Science Foundation of China (Grant No. 51709134)the National Key R&D Program of China (Grant No. 2016YFC0300603-02)the Natural Science Foundation of Jiangsu Province (Grant Nos. BK20160559 and BK20170575)。
文摘With the rapid development of ocean technology, the deep-sea manned submersible is regarded as a high-tech equipment for the exploration and exploitation of ocean resources. The safety of manned cabin has a decisive effect on the whole system. Ti-6 Al-4 V with the superior strength-to-weight ratio and corrosion resistance has been used for the manned cabin. The manned cabin experiences loading spectrum with different maximum stresses and different dwell time during their service life. The load sequence effects on dwell fatigue crack growth behavior of Ti-6 Al-4 V under different dwell time are investigated experimentally in this paper. The experimental results show that the crack tip plastic zone is enlarged by the dwell time and the overload retardation zone increases with dwell time under the same overload rate. A dwell fatigue crack growth model is proposed by modifying the crack tip plastic zone under the loading history with combinations of the single overload and dwell time factors are included in the modified model. Based on the experimental data, the overload retardation zone and the crack growth rates of Ti-6 Al-4 V are predicted by the modified model. A reasonable model for the load sequence effect on the dwell fatigue crack growth rates of Ti-6 Al-4 V is verified.
基金supported by National Natural Science Foundation of China(No.51802257)Natural Science Foundation of Shaanxi Provincial Department of Education(18JK0570)China Postdoctoral Science Foundation(2019M663788).
文摘Hetero-element doped lithium orthosilicates have been considered as advanced tritium breeders due to the superior performances.In this work,Li_(4)Si_(1-x)Ti_(x)O_(4) ceramics were prepared by proprietary hydrothermal process and multistage reactive sintering.The reaction mechanism of Li_(4)Si_(1-x)Ti_(x)O_(4) was put forward.XRD and SEM analyses indicate that insertion of Ti leads to lattice expansion,which promotes the grain growth and changes the fracture mode.The compressive tests show that the crush load increases almost four times by increasing x from 0 to 0.2.However,the thermal conductivity and ionic conductivity are the best when x=0.05 and x=0.1,respectively.Thermal cycling stability of Li_(4)Si_(1-x)Ti_(x)O_(4) pebbles was further appraised through investigating the changes of microstructure and crush load.After undergoing thermal cycling,the Li_(4)Si_(1-x)Ti_(x)O_(4) still show higher crush load compared with Li_(4)SiO_(4),despite Ti segregation in some samples.The x=0.05 sample exhibits excellent thermal cycling stability.In summary,proper amount of Ti doping can improve the crush load,thermal and ionic conductivity,and thermal cycling stability of Li_(4)SiO_(4).