A remote open-path laser-induced breakdown spectroscopy(LIBS) system was designed and studied in the present work for the purpose of combining the LIBS technique with the steel production line. In this system, the rel...A remote open-path laser-induced breakdown spectroscopy(LIBS) system was designed and studied in the present work for the purpose of combining the LIBS technique with the steel production line. In this system, the relatively simple configuration and optics were employed to measure the steel samples at a remote distance and a hot sample temperature. The system has obtained a robustness for the deviation of the sample position because of the open-path and alloptical structure. The measurement was carried out at different sample temperatures by placing the samples in a muffle furnace with a window in the front door. The results show that the intensity of the spectral lines increased as the sample temperature increased. The influence of the sample temperature on the quantitative analysis of manganese in the steel samples was investigated by measuring ten standard steel samples at different temperatures. Three samples were selected as the test sample for the simulation measurement. The results show that, at the sample temperature of 500 ℃, the average relative error of prediction is 3.1% and the average relative standard deviation is 7.7%, respectively.展开更多
Our recent work has determined the carbon content in a melting ferroalloy by laser- induced breakdown spectroscopy (LIBS). The emission spectrum of carbon that we obtained in the laboratory is suitable for carbon co...Our recent work has determined the carbon content in a melting ferroalloy by laser- induced breakdown spectroscopy (LIBS). The emission spectrum of carbon that we obtained in the laboratory is suitable for carbon content determination in a melting ferroalloy but we cannot get the expected results when this method is applied in industrial conditions: there is always an unacceptable error of around 4% between the actual value and the measured value. By comparing the measurement condition in the industrial condition with that in the laboratory, the results show that the temperature of the molten ferroalloy samples to be measured is constant under laboratory conditions while it decreases gradually under industrial conditions. However, temperature has a considerable impact on the measurement of carbon content, and this is the reason why there is always an error between the actual value and the measured value. In this paper we compare the errors of carbon content determination at different temperatures to find the optimum reference temperature range which can fit the requirements better in industrial conditions and, hence, make the measurement more accurate. The results of the comparative analyses show that the measured value of the carbon content in molten state (1620 K) is consistent with the nominal value of the solid standard sample (error within 0.7%). In fact, it is the most accurate measurement in the solid state. Based on this, we can effectively improve the accuracy of measurements in laboratory and can provide a reference standard of temperature for the measurement in industrial conditions.展开更多
文摘增强激光诱导等离子体的发射光谱强度,对于精确测量微弱光谱信号,改进待测材料中低含量元素的探测灵敏度意义重要。首先对金属样品加热升温,并且在一定温度时利用波长为1 064 nm的Nd:YAG纳秒脉冲激光烧蚀样品,激发产生等离子体,测量了不同样品温度条件下等离子体的发射光谱强度和信噪比。结果表明,采用的激光能量为200 m J时,随着样品温度的升高,等离子体辐射会逐渐增强,并且在温度为150℃时达到最大。计算表明,样品中分析元素Mo、Cr、Ni和Mn在温度为150℃时的光谱线强度比室温条件下的分别提高了54.56%,72.43%,70.29%和54.01%,光谱信噪比分别增大了37.44%,40.74%,38.6%和37.06%。实验还通过观察等离子体的照片,测量等离子体的温度、电子密度和样品蒸发量,讨论了激光诱导金属等离子体辐射增强的原因。可见,升高样品温度是改善激光等离子体光谱质量的一种有效手段。
基金supported by National Natural Science Foundation of China (Nos. 51506171 and 51675415)National Natural Science Foundation of China for Key Program (No. 51335009)+1 种基金National Key Research and Development Program of China (No. 2017YFD0700200)the joint research fund between Tokushima University and Xi’an Jiaotong University
文摘A remote open-path laser-induced breakdown spectroscopy(LIBS) system was designed and studied in the present work for the purpose of combining the LIBS technique with the steel production line. In this system, the relatively simple configuration and optics were employed to measure the steel samples at a remote distance and a hot sample temperature. The system has obtained a robustness for the deviation of the sample position because of the open-path and alloptical structure. The measurement was carried out at different sample temperatures by placing the samples in a muffle furnace with a window in the front door. The results show that the intensity of the spectral lines increased as the sample temperature increased. The influence of the sample temperature on the quantitative analysis of manganese in the steel samples was investigated by measuring ten standard steel samples at different temperatures. Three samples were selected as the test sample for the simulation measurement. The results show that, at the sample temperature of 500 ℃, the average relative error of prediction is 3.1% and the average relative standard deviation is 7.7%, respectively.
基金supported by National Natural Science Foundation of China(No.51374040)supported by Laser-Induced Plasma Spectroscopy Equipment Development and Application,China(No.2014YQ120351)
文摘Our recent work has determined the carbon content in a melting ferroalloy by laser- induced breakdown spectroscopy (LIBS). The emission spectrum of carbon that we obtained in the laboratory is suitable for carbon content determination in a melting ferroalloy but we cannot get the expected results when this method is applied in industrial conditions: there is always an unacceptable error of around 4% between the actual value and the measured value. By comparing the measurement condition in the industrial condition with that in the laboratory, the results show that the temperature of the molten ferroalloy samples to be measured is constant under laboratory conditions while it decreases gradually under industrial conditions. However, temperature has a considerable impact on the measurement of carbon content, and this is the reason why there is always an error between the actual value and the measured value. In this paper we compare the errors of carbon content determination at different temperatures to find the optimum reference temperature range which can fit the requirements better in industrial conditions and, hence, make the measurement more accurate. The results of the comparative analyses show that the measured value of the carbon content in molten state (1620 K) is consistent with the nominal value of the solid standard sample (error within 0.7%). In fact, it is the most accurate measurement in the solid state. Based on this, we can effectively improve the accuracy of measurements in laboratory and can provide a reference standard of temperature for the measurement in industrial conditions.