Objective: This study aimed to evaluate of the accuracy and efficiency of the in-vivo dosimetry systems for routine cancer patient dose verification. Methods: In vivo dosimetry, using diodes and thermoluminescent do...Objective: This study aimed to evaluate of the accuracy and efficiency of the in-vivo dosimetry systems for routine cancer patient dose verification. Methods: In vivo dosimetry, using diodes and thermoluminescent dosimeters (TLD) is performed in many radiotherapy departments to verify the dose delivered during treatment. A total of 40 TLD divided into two batches (one of 20 and other of 20 TLD) were used. Different doses of Co6~ beam were delivered to the TLD chips at different depths. Diodes were irradiated at different depths in a (30 x 30 x 30) cm3 water slab phantom with various conditions of Field sizes, monitor units and SSDs. Results: The limitation of the in-vivo dosimetry technique is that dose can only be in system readout difficulty and type of readout (TLD system and diode) as the patient dose is directly measured. Several authors have investigated the measurements was 1.3%, with a standard deviation of 2.6%. Results were normally distributed around a mean as -0.39 and 0.34 respectively. After the evaluation of in vivo dosimetry brain case as an example, the mean doses for both eyes were 1.8%, with a standard deviation of 2.7%. These results are similar to studies conducted with diodes and TLD's. Conclusion: The diode is superior to TLD, since the diode measurements can be obtained on line and allows an immediate check. Other advantages of diodes include high sensitivity, good spatial resolution, and small size, simplicity of used.展开更多
Tuned liquid damper is one the passive structural control ways which has been used since mid 1980 decade for seismic control in civil engineering. This system is made of one or many tanks filled with fluid, mostly wat...Tuned liquid damper is one the passive structural control ways which has been used since mid 1980 decade for seismic control in civil engineering. This system is made of one or many tanks filled with fluid, mostly water that installed on top of the high raised structure and used to prevent structure vibration. In this article we will show how to make seismic table contain TLD system and analysis the result of using this system in our structure. Results imply that when frequency ratio approaches 1 this system can perform its best in both dissipate energy and increasing structural damping. And also results of these serial experiments are proved compatible with Hunzer linear theory behavior.展开更多
基金Supported by grants from the Al-Hosain Hospital, Faculty of Medicine, Al Azhar University and Tanta University
文摘Objective: This study aimed to evaluate of the accuracy and efficiency of the in-vivo dosimetry systems for routine cancer patient dose verification. Methods: In vivo dosimetry, using diodes and thermoluminescent dosimeters (TLD) is performed in many radiotherapy departments to verify the dose delivered during treatment. A total of 40 TLD divided into two batches (one of 20 and other of 20 TLD) were used. Different doses of Co6~ beam were delivered to the TLD chips at different depths. Diodes were irradiated at different depths in a (30 x 30 x 30) cm3 water slab phantom with various conditions of Field sizes, monitor units and SSDs. Results: The limitation of the in-vivo dosimetry technique is that dose can only be in system readout difficulty and type of readout (TLD system and diode) as the patient dose is directly measured. Several authors have investigated the measurements was 1.3%, with a standard deviation of 2.6%. Results were normally distributed around a mean as -0.39 and 0.34 respectively. After the evaluation of in vivo dosimetry brain case as an example, the mean doses for both eyes were 1.8%, with a standard deviation of 2.7%. These results are similar to studies conducted with diodes and TLD's. Conclusion: The diode is superior to TLD, since the diode measurements can be obtained on line and allows an immediate check. Other advantages of diodes include high sensitivity, good spatial resolution, and small size, simplicity of used.
文摘Tuned liquid damper is one the passive structural control ways which has been used since mid 1980 decade for seismic control in civil engineering. This system is made of one or many tanks filled with fluid, mostly water that installed on top of the high raised structure and used to prevent structure vibration. In this article we will show how to make seismic table contain TLD system and analysis the result of using this system in our structure. Results imply that when frequency ratio approaches 1 this system can perform its best in both dissipate energy and increasing structural damping. And also results of these serial experiments are proved compatible with Hunzer linear theory behavior.