Detection of minor faults in power transformer active part is essential because minor faults may develop and lead to major faults and finally irretrievable damages occur. Sweep Frequency Response Analysis (SFRA) is an...Detection of minor faults in power transformer active part is essential because minor faults may develop and lead to major faults and finally irretrievable damages occur. Sweep Frequency Response Analysis (SFRA) is an effective low-voltage, off-line diagnostic tool used for finding out any possible winding displacement or mechanical deterioration inside the Transformer, due to large electromechanical forces occurring from the fault currents or due to Transformer transportation and relocation. In this method, the frequency response of a transformer is taken both at manufacturing industry and concern site. Then both the response is compared to predict the fault taken place in active part. But in old aged transformers, the primary reference response is unavailable. So Cross Correlation Co-Efficient (CCF) measurement technique can be a vital process for fault detection in these transformers. In this paper, theoretical background of SFRA technique has been elaborated and through several case studies, the effectiveness of CCF parameter for fault detection has been represented.展开更多
With the prevailing power scenario, every watt-second of electrical energy has its own merit in satisfying the consumer demand. At the state of such a stringent energy demanding era, failure of a power generation equi...With the prevailing power scenario, every watt-second of electrical energy has its own merit in satisfying the consumer demand. At the state of such a stringent energy demanding era, failure of a power generation equipment compounds the energy constraints which will not only result in a huge loss of generation but also have an impact on capital revenue. The unexpected failure of generator step-up (GSU) transformer is espe- cially a major disturbance in the power system operation and leads to unscheduled outages with power delivery problems. The time lag in bringing back the equipment in service after rectification or replacement may increase the criticality as the process involves mobilization of spares and maintenance professionals. Hot atmosphere existing in the vicinity of thermal power stations running round-the- clock with more than 100% plant load factor (PLF) increases the thermal stress of the electrical insulation which leads to premature failure of windings, bushings, core laminations, etc. The healthy state of the GSU transformer has to be ensured to minimize the loss of power generation. As the predication related to failure of a GSU transformer is associated with some uncertainties, a fuzzy approach is employed in this paper along with actual field data and case studies for the well-being analysis of GSU transformer.展开更多
文摘Detection of minor faults in power transformer active part is essential because minor faults may develop and lead to major faults and finally irretrievable damages occur. Sweep Frequency Response Analysis (SFRA) is an effective low-voltage, off-line diagnostic tool used for finding out any possible winding displacement or mechanical deterioration inside the Transformer, due to large electromechanical forces occurring from the fault currents or due to Transformer transportation and relocation. In this method, the frequency response of a transformer is taken both at manufacturing industry and concern site. Then both the response is compared to predict the fault taken place in active part. But in old aged transformers, the primary reference response is unavailable. So Cross Correlation Co-Efficient (CCF) measurement technique can be a vital process for fault detection in these transformers. In this paper, theoretical background of SFRA technique has been elaborated and through several case studies, the effectiveness of CCF parameter for fault detection has been represented.
文摘With the prevailing power scenario, every watt-second of electrical energy has its own merit in satisfying the consumer demand. At the state of such a stringent energy demanding era, failure of a power generation equipment compounds the energy constraints which will not only result in a huge loss of generation but also have an impact on capital revenue. The unexpected failure of generator step-up (GSU) transformer is espe- cially a major disturbance in the power system operation and leads to unscheduled outages with power delivery problems. The time lag in bringing back the equipment in service after rectification or replacement may increase the criticality as the process involves mobilization of spares and maintenance professionals. Hot atmosphere existing in the vicinity of thermal power stations running round-the- clock with more than 100% plant load factor (PLF) increases the thermal stress of the electrical insulation which leads to premature failure of windings, bushings, core laminations, etc. The healthy state of the GSU transformer has to be ensured to minimize the loss of power generation. As the predication related to failure of a GSU transformer is associated with some uncertainties, a fuzzy approach is employed in this paper along with actual field data and case studies for the well-being analysis of GSU transformer.