The large cylinder is a new-type structure that has been applied to harbor and offshore engineering. An analytic method of the relationship between loads and the structure displacement is developed based on the failur...The large cylinder is a new-type structure that has been applied to harbor and offshore engineering. An analytic method of the relationship between loads and the structure displacement is developed based on the failure mode of deep embedded large cylinder structures. It can be used to calculate directly the soil resistance and the ultimate bearing capacity of the structure under usage. A new criterion of the large cylinder structure, which discriminates the deep embedded cylinder from the shallow embedded cylinder, is defined. Model tests prove that the proposed method is feasible for the analysis of deep embedded large cylinder structures.展开更多
Currently, land resources are becoming more and more constrained and structures are getting closer to each other. To investigate the seismic response of inter-story isolated structure to adjacent structure, models con...Currently, land resources are becoming more and more constrained and structures are getting closer to each other. To investigate the seismic response of inter-story isolated structure to adjacent structure, models considering no soil-structure interaction (SSI), considering soil-structure interaction (SSI), and considering structure-soil-structure interaction (SSSI) were established. Nonlinear seismic response comparative analysis was conducted by varying the spacing between adjacent structure and inter-story isolated structure, as well as the weight of adjacent structure, under different earthquake inputs, in order to obtain the structural response characteristics. The results indicate that the inter-story drift and inter-story shear of the inter-story isolated structure without considering SSI are smaller than those considering SSI and SSSI. The inter-story drift and inter-story shear of the inter-story isolated structure considering SSSI are further affected compared to that of the inter-story isolated structure considering only SSI. As the spacing between adjacent structure and inter-story isolated structure increases, the influence of adjacent structure on inter-story isolated structure decreases. The variation in the spacing between the two structures has a negligible effect on the isolation layer of the inter-story isolated structure. With the increase in the weight of adjacent structure, the influence of adjacent structure on inter-story isolated structure becomes more significant. The increasing weight of adjacent structure has an increasing effect on the Isolation layer of the inter-story isolated structure.展开更多
文摘The large cylinder is a new-type structure that has been applied to harbor and offshore engineering. An analytic method of the relationship between loads and the structure displacement is developed based on the failure mode of deep embedded large cylinder structures. It can be used to calculate directly the soil resistance and the ultimate bearing capacity of the structure under usage. A new criterion of the large cylinder structure, which discriminates the deep embedded cylinder from the shallow embedded cylinder, is defined. Model tests prove that the proposed method is feasible for the analysis of deep embedded large cylinder structures.
文摘Currently, land resources are becoming more and more constrained and structures are getting closer to each other. To investigate the seismic response of inter-story isolated structure to adjacent structure, models considering no soil-structure interaction (SSI), considering soil-structure interaction (SSI), and considering structure-soil-structure interaction (SSSI) were established. Nonlinear seismic response comparative analysis was conducted by varying the spacing between adjacent structure and inter-story isolated structure, as well as the weight of adjacent structure, under different earthquake inputs, in order to obtain the structural response characteristics. The results indicate that the inter-story drift and inter-story shear of the inter-story isolated structure without considering SSI are smaller than those considering SSI and SSSI. The inter-story drift and inter-story shear of the inter-story isolated structure considering SSSI are further affected compared to that of the inter-story isolated structure considering only SSI. As the spacing between adjacent structure and inter-story isolated structure increases, the influence of adjacent structure on inter-story isolated structure decreases. The variation in the spacing between the two structures has a negligible effect on the isolation layer of the inter-story isolated structure. With the increase in the weight of adjacent structure, the influence of adjacent structure on inter-story isolated structure becomes more significant. The increasing weight of adjacent structure has an increasing effect on the Isolation layer of the inter-story isolated structure.