Previous studies have proposed higher requirements for the transient characteristics of a DC transformer used in a flexible high-voltage direct current(HVDC) system to achieve faster sampling speed and meet wider band...Previous studies have proposed higher requirements for the transient characteristics of a DC transformer used in a flexible high-voltage direct current(HVDC) system to achieve faster sampling speed and meet wider bandwidth requirements of the control and protection signal, and to eventually suppress the large transient fault current. In this study, a transient characteristics verification method is proposed for transient characteristics verification of a DC transformer used in a flexible HVDC system based on resampling technology and LabVIEW measurement technology after analyzing the key technology for transient characteristics verification of a DC transformer. A laboratory experiment for the transient characteristics of a full-fiber electronic DC transformer is conducted, and experimental results show that such verification method can be employed for frequency response and step response verification of a DC transformer at 10% of the rated voltage and current, and can eventually improve the screening of a DC transformer.展开更多
The validity of electric power system simulation or prediction models depends on static load model. Measurement- based approach is the unique method to identify them adequately. The measured power depends on both load...The validity of electric power system simulation or prediction models depends on static load model. Measurement- based approach is the unique method to identify them adequately. The measured power depends on both load reaction to supply voltage alteration and random process of load alteration Basically, there is no any universal method that can single out the inherent static load model from experimental data. The paper offers a proprietary technique which is the particular solution of the task. The technique considers the selection of neighboring measurement pairs with the supply voltage altering significantly be-tween them, the exclusion of selected pairs by load power factor and subsequent selection of the inherent static load model presented as the polynomial load model. The usage of the technique to identify static load model at “Fenster” industrial enterprise (in Borisov city) is presented. The ideas considered in the paper can be used for future development of static load model identification methods with the data obtained during both active experiment and in other operating models of electric power systems.展开更多
针对风电场集电系统升压变压器和避雷器在雷害事故中大量损坏现状,在雷害事故现场调查的基础上,对风电场电缆集电系统雷电暂态过电压及电流分布进行了数值计算。建立了单台机组模型和多台机组模型,考虑了风电机组数量、雷电流幅值、机...针对风电场集电系统升压变压器和避雷器在雷害事故中大量损坏现状,在雷害事故现场调查的基础上,对风电场电缆集电系统雷电暂态过电压及电流分布进行了数值计算。建立了单台机组模型和多台机组模型,考虑了风电机组数量、雷电流幅值、机组冲击接地电阻等各种因素对雷电暂态过电压和雷电流分布影响。结果表明:避雷器标称放电电流偏小是雷击损坏主要原因,多次回击电流将导致避雷器以及与其并联连接的升压变压器损坏。对于35 kV风电场电缆集电系统,如果风电机组冲击接地电阻很难降低,提高避雷器标称放电电流可以有效解决电缆集电系统雷电暂态过电压和避雷器保护问题。根据计算结果提出了避雷器标称放电电流推荐值,当雷电流幅值<50 k A时,标称放电电流5 k A的避雷器可满足要求;当雷电流幅值≥100 k A时,则需要相应提高避雷器标称放电电流。对风电场电缆集电系统,在接线工艺规范的前提下,升压变压器高压侧安装1组避雷器可以满足过电压保护和绝缘配合要求。展开更多
基金supported by the State Grid Corporation Science and Technology Project(No.JL71-15-039)
文摘Previous studies have proposed higher requirements for the transient characteristics of a DC transformer used in a flexible high-voltage direct current(HVDC) system to achieve faster sampling speed and meet wider bandwidth requirements of the control and protection signal, and to eventually suppress the large transient fault current. In this study, a transient characteristics verification method is proposed for transient characteristics verification of a DC transformer used in a flexible HVDC system based on resampling technology and LabVIEW measurement technology after analyzing the key technology for transient characteristics verification of a DC transformer. A laboratory experiment for the transient characteristics of a full-fiber electronic DC transformer is conducted, and experimental results show that such verification method can be employed for frequency response and step response verification of a DC transformer at 10% of the rated voltage and current, and can eventually improve the screening of a DC transformer.
文摘The validity of electric power system simulation or prediction models depends on static load model. Measurement- based approach is the unique method to identify them adequately. The measured power depends on both load reaction to supply voltage alteration and random process of load alteration Basically, there is no any universal method that can single out the inherent static load model from experimental data. The paper offers a proprietary technique which is the particular solution of the task. The technique considers the selection of neighboring measurement pairs with the supply voltage altering significantly be-tween them, the exclusion of selected pairs by load power factor and subsequent selection of the inherent static load model presented as the polynomial load model. The usage of the technique to identify static load model at “Fenster” industrial enterprise (in Borisov city) is presented. The ideas considered in the paper can be used for future development of static load model identification methods with the data obtained during both active experiment and in other operating models of electric power systems.
文摘针对风电场集电系统升压变压器和避雷器在雷害事故中大量损坏现状,在雷害事故现场调查的基础上,对风电场电缆集电系统雷电暂态过电压及电流分布进行了数值计算。建立了单台机组模型和多台机组模型,考虑了风电机组数量、雷电流幅值、机组冲击接地电阻等各种因素对雷电暂态过电压和雷电流分布影响。结果表明:避雷器标称放电电流偏小是雷击损坏主要原因,多次回击电流将导致避雷器以及与其并联连接的升压变压器损坏。对于35 kV风电场电缆集电系统,如果风电机组冲击接地电阻很难降低,提高避雷器标称放电电流可以有效解决电缆集电系统雷电暂态过电压和避雷器保护问题。根据计算结果提出了避雷器标称放电电流推荐值,当雷电流幅值<50 k A时,标称放电电流5 k A的避雷器可满足要求;当雷电流幅值≥100 k A时,则需要相应提高避雷器标称放电电流。对风电场电缆集电系统,在接线工艺规范的前提下,升压变压器高压侧安装1组避雷器可以满足过电压保护和绝缘配合要求。