Robust and easy-to-handle solid-contact ion-selective electrodes (SC-ISEs) based on graphite paste have been developed for the potentiometric detection of NO-3 and NH+4 in environmental samples. Polypyrrole (PPy) has ...Robust and easy-to-handle solid-contact ion-selective electrodes (SC-ISEs) based on graphite paste have been developed for the potentiometric detection of NO-3 and NH+4 in environmental samples. Polypyrrole (PPy) has been used as intermediate layer and solid contact between the electron-conducting graphite paste substrate and the ion-conducting polyvinylchloride (PVC)-containing membrane with the immobilized ionophore. For the nitrate- and ammonium-selective electrodes, tridodecylmethylammonium nitrate (TDMA-NO3) and nonactin have been used as ion-complexing compounds, respectively. Both ISEs show nearly Nernstian response in the linear range from 10-5 mol/L to 10-1 mol/L with average slopes of >58 mV/decade. The ISEs possess short response times (<20 s).展开更多
In recent years, there has been a pronounced interest in solid-contact ion-selective electrodes (SC-ISEs), with emphasis on the use of conducting polymers as ion-to-electron transducer. In this work, a ladder conjug...In recent years, there has been a pronounced interest in solid-contact ion-selective electrodes (SC-ISEs), with emphasis on the use of conducting polymers as ion-to-electron transducer. In this work, a ladder conjugated polymer, thieno[3,2-b]thiophene (LCPT), was investigated in fabricating Cu2+-selective electrodes for the first time. The resulting electrodes were characterized by electrochemical impedance spectroscopy (EIS), chronopotentiometry, and the water layer test. Results proved that the active LCPT facilitates the ion-to-electron transduction, and avoids the detrimental aqueous layer formed at the interface of SC-ISEs.展开更多
A comparative study was conducted using two designs of a roxatidine acetate (ROX)-selective electrode; a conventional liquid inner contact called electrode A and a graphite-coated solid contact called electrode 13. ...A comparative study was conducted using two designs of a roxatidine acetate (ROX)-selective electrode; a conventional liquid inner contact called electrode A and a graphite-coated solid contact called electrode 13. The fabrication of electrodes was based on roxatidine-tetraphenylborate (ROX-TPB) as an ion-association complex in a PVC matrix using different plasticizers. Electrode A has a linear dynamic range of 2.2 ×10^-5 mol/L to 1.0 ×10^-2 mol/L, with a Nernstian slope of 54.7 mV/decade and a detection limit of 1.4 ×10^-6 mol/L. Electrode B shows linearity over the concentration range of 1.0×10^-6 mol/L to 1.0×10^-2 tool/L, with a Nernstian slope of 51.2 mV/decade and a limit of detection of 1.1×10^7 mol/L which is remarkably improved as a result of diminishing ion fluxes in this solid contact, ion-selective electrode. The proposed sensors display useful analytical characteristics for the determination of ROX in bulk powder and its pharmaceutical formulation. The present electrodes show clear discrimination of ROX from several inorganic, organic ions, sugars, some common drug excipients and the degradation product (3-[3-(1-piperidinyl methyl) phenoxy] propyl amine) of ROX. Furthermore, the proposed electrodes were utilized for the determination of ROX in human plasma, where electrode B covers drug Cmax which indicated its applicability to pharmacokinetic, bioavailability and bioequivalent studies. The results obtained by the proposed electrodes were statistically analyzed and compared with those obtained by a reported HPLC method. No significant difference for either accuracy or precision was observed.展开更多
文摘Robust and easy-to-handle solid-contact ion-selective electrodes (SC-ISEs) based on graphite paste have been developed for the potentiometric detection of NO-3 and NH+4 in environmental samples. Polypyrrole (PPy) has been used as intermediate layer and solid contact between the electron-conducting graphite paste substrate and the ion-conducting polyvinylchloride (PVC)-containing membrane with the immobilized ionophore. For the nitrate- and ammonium-selective electrodes, tridodecylmethylammonium nitrate (TDMA-NO3) and nonactin have been used as ion-complexing compounds, respectively. Both ISEs show nearly Nernstian response in the linear range from 10-5 mol/L to 10-1 mol/L with average slopes of >58 mV/decade. The ISEs possess short response times (<20 s).
基金financially supported by the National Natural Science Foundation of China(No.21107134)Chinese Academy of Sciences(No.KZCX2-YW-JS208)+1 种基金the Natural Science Foundation of Shandong Province(No.JQ200814)the Taishan Scholar Program of Shandong Province
文摘In recent years, there has been a pronounced interest in solid-contact ion-selective electrodes (SC-ISEs), with emphasis on the use of conducting polymers as ion-to-electron transducer. In this work, a ladder conjugated polymer, thieno[3,2-b]thiophene (LCPT), was investigated in fabricating Cu2+-selective electrodes for the first time. The resulting electrodes were characterized by electrochemical impedance spectroscopy (EIS), chronopotentiometry, and the water layer test. Results proved that the active LCPT facilitates the ion-to-electron transduction, and avoids the detrimental aqueous layer formed at the interface of SC-ISEs.
文摘A comparative study was conducted using two designs of a roxatidine acetate (ROX)-selective electrode; a conventional liquid inner contact called electrode A and a graphite-coated solid contact called electrode 13. The fabrication of electrodes was based on roxatidine-tetraphenylborate (ROX-TPB) as an ion-association complex in a PVC matrix using different plasticizers. Electrode A has a linear dynamic range of 2.2 ×10^-5 mol/L to 1.0 ×10^-2 mol/L, with a Nernstian slope of 54.7 mV/decade and a detection limit of 1.4 ×10^-6 mol/L. Electrode B shows linearity over the concentration range of 1.0×10^-6 mol/L to 1.0×10^-2 tool/L, with a Nernstian slope of 51.2 mV/decade and a limit of detection of 1.1×10^7 mol/L which is remarkably improved as a result of diminishing ion fluxes in this solid contact, ion-selective electrode. The proposed sensors display useful analytical characteristics for the determination of ROX in bulk powder and its pharmaceutical formulation. The present electrodes show clear discrimination of ROX from several inorganic, organic ions, sugars, some common drug excipients and the degradation product (3-[3-(1-piperidinyl methyl) phenoxy] propyl amine) of ROX. Furthermore, the proposed electrodes were utilized for the determination of ROX in human plasma, where electrode B covers drug Cmax which indicated its applicability to pharmacokinetic, bioavailability and bioequivalent studies. The results obtained by the proposed electrodes were statistically analyzed and compared with those obtained by a reported HPLC method. No significant difference for either accuracy or precision was observed.