Background and Aims: A gynaecological cream containing collagen, phytocollagen, hyaluronate and vitamins was investigated in women in menopause. Methods: The cream was daily applied to the vaginal mucosa and the perin...Background and Aims: A gynaecological cream containing collagen, phytocollagen, hyaluronate and vitamins was investigated in women in menopause. Methods: The cream was daily applied to the vaginal mucosa and the perineal skin as well as to the abdominal skin (healthy skin used as control) for 1 week and then on alternate days for other 2 weeks. Skin hydration and viscoelasticity were measured at baseline and after 8 and 21 days by Corneometer? CM 825 and Cutometer? MPA 850, respectively. The product use comfort and the moisturising of the vaginal mucosa were evaluated by the volunteers through a questionnaire and a visual analogue scale, respectively. Results: The local tolerability was excellent for nearly all of the volunteers (90% - 95%) and according both to dermatologist’s and gynaecologist’s evaluation. Related adverse reactions had a frequency of 15% (10% vulvovaginal burning sensation and 5% vulvovaginal discomfort). The topical hydration increased both in the perineal and the abdominal skin. Hydration increase vs. baseline was more marked on day 8 than on day 21 and was significant in the abdominal skin (p-value < 0.0001). The vaginal moisturising improved significantly (p-value < 0.0001) both on day 8 and 21 vs. baseline. Small changes in the viscoelasticity parameters were observed in both the perineal and the abdominal skin. Few significant improvements were R1 and R8 decreases in the perineum and R0 increase in the abdomen. Conclusions: The tested cream represents a safe product with proven moisturising effect towards the vaginal mucosa when daily applied by menopausal women.展开更多
The expanded skin specimens of dogs and their controls atdifferent stages after grafting were studied. The stress-strain,stress-relaxation viscoelastic characteristics and tensile strengthwere measured. The results sh...The expanded skin specimens of dogs and their controls atdifferent stages after grafting were studied. The stress-strain,stress-relaxation viscoelastic characteristics and tensile strengthwere measured. The results show that, during the initial stage aftergrafting, the biomechanical properties of expanded speci- mensdeviate from those controls significantly. But the biomechanicalproperties of expanded speci- mens and their controls begin to closegradually in a longer recovering time. And when the recovering timereaches 24 weeks or longer, the experimental specimens exhibit thesame mechanical characteristics as their controls. It is shown thatviscoelasticity of expansive skin varies with time after grafting.展开更多
It has been reported that overweight Japanese males have poorly organised dermis and their skin may be fragile to external forces because of decreased dermal echogenicity. However, it is unknown whether the changes in...It has been reported that overweight Japanese males have poorly organised dermis and their skin may be fragile to external forces because of decreased dermal echogenicity. However, it is unknown whether the changes in the dermal structure actually affect the dermal function. The objective of this study was to clarify the relationship between dermal structural parameters and dermal functional parameters in overweight and obese Japanese males. A cross-sectional, observational study was conducted on Japanese male volunteers. Two ultrasound scanners, a 20-MHz Dermascan C<sup>®</sup> and an 18-MHz Mylab<sup>TM</sup> five<sup>®</sup> were used to evaluate dermal structure. Echogenicity of the lower dermis and dermal thickness of the participants’ abdomens and thighs were measured. A Cutometer<sup>®</sup> MPA580 was used to evaluate skin viscoelasticity, skin deformation (R0) and elasticity (R2, R7). The correlation between dermal structural parameters and skin viscoelasticity were validated using Pearson’s correlation coefficient or Spearman’s correlation coefficient by rank test. A total of 79 male volunteers were recruited of which 43 were control subjects with BMI <25 (age, 22 - 63 years), 25 were overweight subjects with BMI ≥ 25 to <30 (age, 23 - 64 years) and the 11 obese subjects had a BMI ≥ 30 (age, 26 - 47 years). There was no correlation between dermal structural parameters and skin viscoelasticity in the abdomens or thighs of all 79 participants. On the other hand, in the 36 overweight and obese participants, thigh dermal echogenicity was significantly and negatively correlated with R0 (r = -0.456, p < 0.01) and dermal thickness in the abdomen was significantly and positively correlated with R0 (r = 0.464, p < 0.01). The dermal functional parameter was significantly correlated with dermal structural parameters in overweight and obese males;in other words, a decrease in dermal function may be caused by structural changes in the dermis during obesity.展开更多
对前臂皮肤黏弹性属性的了解有助于临床康复产品设计。基于动态微印压方法,对6位男性志愿者前臂皮肤进行了测量,最大压入位移为100μm,频率范围为5~30 Hz。前臂皮肤的平均接触刚度和平均接触阻尼系数分别为(165.02±9.40)N/m、(0.22...对前臂皮肤黏弹性属性的了解有助于临床康复产品设计。基于动态微印压方法,对6位男性志愿者前臂皮肤进行了测量,最大压入位移为100μm,频率范围为5~30 Hz。前臂皮肤的平均接触刚度和平均接触阻尼系数分别为(165.02±9.40)N/m、(0.22±0.047)Ns/m,平均储能模量为(41.25±2.35)k Pa,平均损耗模量为5.37±2.83 k Pa,平均复模量值为41.59 k Pa。结果表明前臂皮肤层的黏弹性属性采用Kelvin线性黏弹性模型描述具有一定合理性。展开更多
Pain sensation may appear under long-lasting mechanical stimulation. Although people have the experience that pain sensation generally decreases with time while the stimulation remains, the underlying mechanism remain...Pain sensation may appear under long-lasting mechanical stimulation. Although people have the experience that pain sensation generally decreases with time while the stimulation remains, the underlying mechanism remains elusive. We experimentally studied the thermal and strain rate- dependent viscoelastic behavior of skin in uniaxial stretch and numerically investigated the effects of temperature and strain rate on pain sensation. The results indicate that the viscosity of skin tissue decreases with increasing temperature and reducing strain rate, which subsequently decreases the discharge frequency of skin nociceptor and thus relieves the pain sensation. The results would contribute to the understanding of pain relief mechanism and optimizing for mechanical treatment.展开更多
文摘Background and Aims: A gynaecological cream containing collagen, phytocollagen, hyaluronate and vitamins was investigated in women in menopause. Methods: The cream was daily applied to the vaginal mucosa and the perineal skin as well as to the abdominal skin (healthy skin used as control) for 1 week and then on alternate days for other 2 weeks. Skin hydration and viscoelasticity were measured at baseline and after 8 and 21 days by Corneometer? CM 825 and Cutometer? MPA 850, respectively. The product use comfort and the moisturising of the vaginal mucosa were evaluated by the volunteers through a questionnaire and a visual analogue scale, respectively. Results: The local tolerability was excellent for nearly all of the volunteers (90% - 95%) and according both to dermatologist’s and gynaecologist’s evaluation. Related adverse reactions had a frequency of 15% (10% vulvovaginal burning sensation and 5% vulvovaginal discomfort). The topical hydration increased both in the perineal and the abdominal skin. Hydration increase vs. baseline was more marked on day 8 than on day 21 and was significant in the abdominal skin (p-value < 0.0001). The vaginal moisturising improved significantly (p-value < 0.0001) both on day 8 and 21 vs. baseline. Small changes in the viscoelasticity parameters were observed in both the perineal and the abdominal skin. Few significant improvements were R1 and R8 decreases in the perineum and R0 increase in the abdomen. Conclusions: The tested cream represents a safe product with proven moisturising effect towards the vaginal mucosa when daily applied by menopausal women.
基金the National Natural Science Foundation of China(No.10072006)
文摘The expanded skin specimens of dogs and their controls atdifferent stages after grafting were studied. The stress-strain,stress-relaxation viscoelastic characteristics and tensile strengthwere measured. The results show that, during the initial stage aftergrafting, the biomechanical properties of expanded speci- mensdeviate from those controls significantly. But the biomechanicalproperties of expanded speci- mens and their controls begin to closegradually in a longer recovering time. And when the recovering timereaches 24 weeks or longer, the experimental specimens exhibit thesame mechanical characteristics as their controls. It is shown thatviscoelasticity of expansive skin varies with time after grafting.
文摘It has been reported that overweight Japanese males have poorly organised dermis and their skin may be fragile to external forces because of decreased dermal echogenicity. However, it is unknown whether the changes in the dermal structure actually affect the dermal function. The objective of this study was to clarify the relationship between dermal structural parameters and dermal functional parameters in overweight and obese Japanese males. A cross-sectional, observational study was conducted on Japanese male volunteers. Two ultrasound scanners, a 20-MHz Dermascan C<sup>®</sup> and an 18-MHz Mylab<sup>TM</sup> five<sup>®</sup> were used to evaluate dermal structure. Echogenicity of the lower dermis and dermal thickness of the participants’ abdomens and thighs were measured. A Cutometer<sup>®</sup> MPA580 was used to evaluate skin viscoelasticity, skin deformation (R0) and elasticity (R2, R7). The correlation between dermal structural parameters and skin viscoelasticity were validated using Pearson’s correlation coefficient or Spearman’s correlation coefficient by rank test. A total of 79 male volunteers were recruited of which 43 were control subjects with BMI <25 (age, 22 - 63 years), 25 were overweight subjects with BMI ≥ 25 to <30 (age, 23 - 64 years) and the 11 obese subjects had a BMI ≥ 30 (age, 26 - 47 years). There was no correlation between dermal structural parameters and skin viscoelasticity in the abdomens or thighs of all 79 participants. On the other hand, in the 36 overweight and obese participants, thigh dermal echogenicity was significantly and negatively correlated with R0 (r = -0.456, p < 0.01) and dermal thickness in the abdomen was significantly and positively correlated with R0 (r = 0.464, p < 0.01). The dermal functional parameter was significantly correlated with dermal structural parameters in overweight and obese males;in other words, a decrease in dermal function may be caused by structural changes in the dermis during obesity.
文摘对前臂皮肤黏弹性属性的了解有助于临床康复产品设计。基于动态微印压方法,对6位男性志愿者前臂皮肤进行了测量,最大压入位移为100μm,频率范围为5~30 Hz。前臂皮肤的平均接触刚度和平均接触阻尼系数分别为(165.02±9.40)N/m、(0.22±0.047)Ns/m,平均储能模量为(41.25±2.35)k Pa,平均损耗模量为5.37±2.83 k Pa,平均复模量值为41.59 k Pa。结果表明前臂皮肤层的黏弹性属性采用Kelvin线性黏弹性模型描述具有一定合理性。
基金supported by the National Natural Science Foundation of China (11372243, 11372243, 1152219)the International Science and Technology Cooperation Program of China (2013DFG02930)
文摘Pain sensation may appear under long-lasting mechanical stimulation. Although people have the experience that pain sensation generally decreases with time while the stimulation remains, the underlying mechanism remains elusive. We experimentally studied the thermal and strain rate- dependent viscoelastic behavior of skin in uniaxial stretch and numerically investigated the effects of temperature and strain rate on pain sensation. The results indicate that the viscosity of skin tissue decreases with increasing temperature and reducing strain rate, which subsequently decreases the discharge frequency of skin nociceptor and thus relieves the pain sensation. The results would contribute to the understanding of pain relief mechanism and optimizing for mechanical treatment.