The protein complex crystallographic beamline BL19U1 at the Shanghai Synchrotron Radiation Facility is one of the five beamlines dedicated to protein sciences operated by National Facility for Protein Science(Shanghai...The protein complex crystallographic beamline BL19U1 at the Shanghai Synchrotron Radiation Facility is one of the five beamlines dedicated to protein sciences operated by National Facility for Protein Science(Shanghai,China).The beamline,which features a small-gap invacuum undulator,has been officially open to users since March 2015.This beamline delivers X-ray in the energy range 7–15 keV.With its high flux,low divergence beam and a large active area detector,BL19U1 is designed for proteins with large molecular weight and large crystallographic unit cell dimensions.Good performance and stable operation of the beamline have allowed the number of Protein Data Bank(PDB)depositions and the number of articles published based on data collected at this beamline to increase steadily.To date,over 300 research groups have collected data at the beamline.More than 600 PDB entries have been deposited at the PDB(www.pdb.org).More than 300 papers have been published that include data collected at the beamline,including 21 research articles published in the top-level journals Cell,Nature,and Science.展开更多
Beamline BL17 U1 at Shanghai Synchrotron Radiation Facility is an energy-tunable macromolecular crystallography beamline that has been in user operation since 2009. Growing demand from the user community for a small b...Beamline BL17 U1 at Shanghai Synchrotron Radiation Facility is an energy-tunable macromolecular crystallography beamline that has been in user operation since 2009. Growing demand from the user community for a small beam and related experimental methods have motivated upgrades of the devices in the endstation.Minibeam modes have already been developed for operation. A self-integrated diffractometer reduces the sphere of confusion of the rotatory axis to 1μm. The new diffractometer is equipped with an upgraded on-axis viewing system that can improve the resolving power. Additionally,the area detector was also upgraded to the newest generation of detectors, the EIGER X 16 M, which can collect data at 133 Hz. After these upgrades, the endstation became virtually new. This paper covers the upgrade of the endstation devices and gives the first data collection results.展开更多
From a safety point of view, it is important to study the damages and reliability of molten salt reactor structural alloy materials, which are subjected to extreme environments due to neutron irradiation, molten salt ...From a safety point of view, it is important to study the damages and reliability of molten salt reactor structural alloy materials, which are subjected to extreme environments due to neutron irradiation, molten salt corrosion, fission product attacks, thermal stress, and even combinations of these. In the past few years, synchrotron radiation-based materials characterization techniques have proven to be effective in revealing the microstructural evolution and failure mechanisms of the alloys under surrogating operation conditions. Here, we review the recent progress in the investigations of molten salt corrosion,tellurium(Te) corrosion, and alloy design. The valence states and distribution of chromium(Cr) atoms, and the diffusion and local atomic structure of Te atoms near the surface of corroded alloys have been investigated using synchrotron radiation techniques, which considerably deepen the understandings on the molten salt and Te corrosion behaviors. Furthermore, the structure and size distribution of the second phases in the alloys have been obtained, which are helpful for the future development of new alloy materials.展开更多
The BL14W1 beamline at Shanghai Synchrotron Radiation Facility(SSRF) is an X-ray absorption finestructure(XAFS) beamline, for investigating atomic local structure, which is demanded extensively in the fields of physic...The BL14W1 beamline at Shanghai Synchrotron Radiation Facility(SSRF) is an X-ray absorption finestructure(XAFS) beamline, for investigating atomic local structure, which is demanded extensively in the fields of physics, chemistry, materials science, environmental science and so on. The beamline is based on a 38-pole wiggler with the maximum magnetic field of 1.2 T. X-rays of 4.5–40 ke V can be extracted by the optical scheme consisting of white beam vertical collimating mirror, liquid-nitrogen-cooled double crystal monochromator of Si(111) and Si(311), toroidal focusing mirror and higher harmonics rejection mirror. The maximum photon flux about 5 × 1012photons/s at the sample at 10 ke V, with a beam size of 0.3 mm × 0.3 mm. The beamline is equipped with four types of detectors for experiments in either transmission or fluorescence mode. At present,quick-XAFS, grazing incidence XAFS, X-ray emission spectroscopy, high-pressure XAFS and time-resolved X-ray excited optical luminescence methods have been developed.展开更多
We report the design of a wide-range energy material beamline(E-line) with multiple experimental techniques at the Shanghai Synchrotron Radiation Facility.The undulators consisted of an elliptically polarizing undulat...We report the design of a wide-range energy material beamline(E-line) with multiple experimental techniques at the Shanghai Synchrotron Radiation Facility.The undulators consisted of an elliptically polarizing undulator and in-vacuum undulator that generate the soft and hard X-rays, respectively. The beamline covered a wide energy range from 130 to 18 ke V with both a high photon flux([ 10^(12) phs/s with exit silt 30 lm in soft X-ray and [ 5 9 10^(12) phs/s in hard X-ray within 0.1%BW bandwidth) and promising resolving power(maximum E/DE [ 15,000 in soft X-ray with exit silt 30 lm and [6000 in hard X-ray). Moreover, the beam spots from the soft and hard X-rays were focused to the same sample position with a high overlap ratio, so that the surfaces, interfaces, and bulk properties were characterized in situ by changing the probing depth.展开更多
In this paper,we report the development of a bunch-by-bunch beam current acquisition system.Through a waveform-reconstruction algorithm,the system realizes high equivalent sampling rate with a relatively low inherent ...In this paper,we report the development of a bunch-by-bunch beam current acquisition system.Through a waveform-reconstruction algorithm,the system realizes high equivalent sampling rate with a relatively low inherent rate.Based on the EPICS environment,information communication with other systems can be achieved.Preliminary test results in commissioning the SSRF storage ring show that the system can reconstruct the beam waveform of single bunch,providing a convenient and reliable method for the top-up operation in the future.展开更多
Beam lifetime is dominated by Touschek scattering at the Shanghai Synchrotron Radiation Facility(SSRF).Touschek loss rate is affected by probability for scattering beyond the RF acceptance and the volume charge densit...Beam lifetime is dominated by Touschek scattering at the Shanghai Synchrotron Radiation Facility(SSRF).Touschek loss rate is affected by probability for scattering beyond the RF acceptance and the volume charge density of the bench.In the phaseⅡupgrade of the SSRF,a third harmonic superconducting cavity will be used to enhance the Touschek lifetime by lengthening the bunches.The Touschek lifetime improvement factor is affected by the voltage of a harmonic cavity.To stabilize the cavity voltage,a tuning control system was designed to control it.The design of the tuning control system was based on the SSRF third-generation low-level RF control system.Some hardware and specialized algorithms were redesigned to fit the harmonic cavity control.The design of the tuning control system is complete,and the control system has been tested.The test result shows that the fluctuation of amplitude is<±0.34%within 1.5 h,which satisfies the stability requirement.展开更多
文摘The protein complex crystallographic beamline BL19U1 at the Shanghai Synchrotron Radiation Facility is one of the five beamlines dedicated to protein sciences operated by National Facility for Protein Science(Shanghai,China).The beamline,which features a small-gap invacuum undulator,has been officially open to users since March 2015.This beamline delivers X-ray in the energy range 7–15 keV.With its high flux,low divergence beam and a large active area detector,BL19U1 is designed for proteins with large molecular weight and large crystallographic unit cell dimensions.Good performance and stable operation of the beamline have allowed the number of Protein Data Bank(PDB)depositions and the number of articles published based on data collected at this beamline to increase steadily.To date,over 300 research groups have collected data at the beamline.More than 600 PDB entries have been deposited at the PDB(www.pdb.org).More than 300 papers have been published that include data collected at the beamline,including 21 research articles published in the top-level journals Cell,Nature,and Science.
基金supported by the Maintenance and Renovation Project for the major infrastructure of the Chinese Academy of Sciencesthe Operation Project of SSRF
文摘Beamline BL17 U1 at Shanghai Synchrotron Radiation Facility is an energy-tunable macromolecular crystallography beamline that has been in user operation since 2009. Growing demand from the user community for a small beam and related experimental methods have motivated upgrades of the devices in the endstation.Minibeam modes have already been developed for operation. A self-integrated diffractometer reduces the sphere of confusion of the rotatory axis to 1μm. The new diffractometer is equipped with an upgraded on-axis viewing system that can improve the resolving power. Additionally,the area detector was also upgraded to the newest generation of detectors, the EIGER X 16 M, which can collect data at 133 Hz. After these upgrades, the endstation became virtually new. This paper covers the upgrade of the endstation devices and gives the first data collection results.
基金supported by the National key research and development program of China(Nos.2016YFB0700401 and 2016YFB0700404)Natural Science Foundation of Shanghai(Nos.19ZR1468200 and 18ZR1448000)+2 种基金National Natural Science Foundation of China(Nos.51671154,51601213 and 51671122)Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDA02004210)Youth Innovation Promotion Association,Chinese Academy of Science(No.2019264)
文摘From a safety point of view, it is important to study the damages and reliability of molten salt reactor structural alloy materials, which are subjected to extreme environments due to neutron irradiation, molten salt corrosion, fission product attacks, thermal stress, and even combinations of these. In the past few years, synchrotron radiation-based materials characterization techniques have proven to be effective in revealing the microstructural evolution and failure mechanisms of the alloys under surrogating operation conditions. Here, we review the recent progress in the investigations of molten salt corrosion,tellurium(Te) corrosion, and alloy design. The valence states and distribution of chromium(Cr) atoms, and the diffusion and local atomic structure of Te atoms near the surface of corroded alloys have been investigated using synchrotron radiation techniques, which considerably deepen the understandings on the molten salt and Te corrosion behaviors. Furthermore, the structure and size distribution of the second phases in the alloys have been obtained, which are helpful for the future development of new alloy materials.
基金Supported by National Natural Science Foundation of China(Nos.11175244,11275256 and 11179024)
文摘The BL14W1 beamline at Shanghai Synchrotron Radiation Facility(SSRF) is an X-ray absorption finestructure(XAFS) beamline, for investigating atomic local structure, which is demanded extensively in the fields of physics, chemistry, materials science, environmental science and so on. The beamline is based on a 38-pole wiggler with the maximum magnetic field of 1.2 T. X-rays of 4.5–40 ke V can be extracted by the optical scheme consisting of white beam vertical collimating mirror, liquid-nitrogen-cooled double crystal monochromator of Si(111) and Si(311), toroidal focusing mirror and higher harmonics rejection mirror. The maximum photon flux about 5 × 1012photons/s at the sample at 10 ke V, with a beam size of 0.3 mm × 0.3 mm. The beamline is equipped with four types of detectors for experiments in either transmission or fluorescence mode. At present,quick-XAFS, grazing incidence XAFS, X-ray emission spectroscopy, high-pressure XAFS and time-resolved X-ray excited optical luminescence methods have been developed.
基金supported by the National Development and Reform Commission(NDRC) of Chinathe National Natural Science Foundation of China(No.11505280)+1 种基金the Shanghai Youth Foundation(No.14YF1407500)the National Science Foundation of China(Nos.11475251,11225527)
文摘We report the design of a wide-range energy material beamline(E-line) with multiple experimental techniques at the Shanghai Synchrotron Radiation Facility.The undulators consisted of an elliptically polarizing undulator and in-vacuum undulator that generate the soft and hard X-rays, respectively. The beamline covered a wide energy range from 130 to 18 ke V with both a high photon flux([ 10^(12) phs/s with exit silt 30 lm in soft X-ray and [ 5 9 10^(12) phs/s in hard X-ray within 0.1%BW bandwidth) and promising resolving power(maximum E/DE [ 15,000 in soft X-ray with exit silt 30 lm and [6000 in hard X-ray). Moreover, the beam spots from the soft and hard X-rays were focused to the same sample position with a high overlap ratio, so that the surfaces, interfaces, and bulk properties were characterized in situ by changing the probing depth.
基金Supported by 100 Talents Programme of The Chinese Academy of Sciences
文摘In this paper,we report the development of a bunch-by-bunch beam current acquisition system.Through a waveform-reconstruction algorithm,the system realizes high equivalent sampling rate with a relatively low inherent rate.Based on the EPICS environment,information communication with other systems can be achieved.Preliminary test results in commissioning the SSRF storage ring show that the system can reconstruct the beam waveform of single bunch,providing a convenient and reliable method for the top-up operation in the future.
文摘Beam lifetime is dominated by Touschek scattering at the Shanghai Synchrotron Radiation Facility(SSRF).Touschek loss rate is affected by probability for scattering beyond the RF acceptance and the volume charge density of the bench.In the phaseⅡupgrade of the SSRF,a third harmonic superconducting cavity will be used to enhance the Touschek lifetime by lengthening the bunches.The Touschek lifetime improvement factor is affected by the voltage of a harmonic cavity.To stabilize the cavity voltage,a tuning control system was designed to control it.The design of the tuning control system was based on the SSRF third-generation low-level RF control system.Some hardware and specialized algorithms were redesigned to fit the harmonic cavity control.The design of the tuning control system is complete,and the control system has been tested.The test result shows that the fluctuation of amplitude is<±0.34%within 1.5 h,which satisfies the stability requirement.