Large-volume liquid scintillator detectors with ultra-low background levels have been widely used to study neutrino physics and search for dark matter.Event vertex and event time are not only useful for event selectio...Large-volume liquid scintillator detectors with ultra-low background levels have been widely used to study neutrino physics and search for dark matter.Event vertex and event time are not only useful for event selection but also essential for the reconstruction of event energy.In this study,four event vertex and event time reconstruction algorithms using charge and time information collected by photomultiplier tubes were analyzed comprehensively.The effects of photomultiplier tube properties were also investigated.The results indicate that the transit time spread is the main effect degrading the vertex reconstruction,while the effect of dark noise is limited.In addition,when the event is close to the detector boundary,the charge information provides better performance for vertex reconstruction than the time information.展开更多
Background Each GECAM satellite payload contains 25 gamma-ray detectors(GRDs),which can detect gamma-rays and particles and can roughly localize the Gamma-Ray Bursts(GRBs).GRD was designed using lanthanum bromide(LaBr...Background Each GECAM satellite payload contains 25 gamma-ray detectors(GRDs),which can detect gamma-rays and particles and can roughly localize the Gamma-Ray Bursts(GRBs).GRD was designed using lanthanum bromide(LaBr3)crystal as the sensitive material with the rear end coupled with silicon photomultiplier(SiPM)array for readout.Purpose In aerospace engineering design of GRD,there are many key points to be studied.In this paper,we present the specific design scheme of GRD,the assembly and the performance test results of detectors.Methods Based on Monte Carlo simulation and experimental test results,the specific schematic design and assembling process of GRD were optimized.After being fully assembled,the GRDs were conducted performance tests by using radioactive source and also conducted random vibration tests.Result and conclusion The test results show that all satellite-borne GRDs have energy resolution<16%at 59.5 keV,meeting requirements of satellite in scientific performance.The random vibration test shows that GRD can maintain in a stable performance,which meets the requirement of spatial application.展开更多
A high detection efficiency calorimeter which is used to detect γ-rays with energies from 1 MeV up to 10 MeV as well as light charged particles has been proposed. Design of the geometry, results of the crystal tests ...A high detection efficiency calorimeter which is used to detect γ-rays with energies from 1 MeV up to 10 MeV as well as light charged particles has been proposed. Design of the geometry, results of the crystal tests and Monte Carlo simulations are presented in this paper. The simulation results confirm that the calorimeter can obtain high detection efficiency and good energy resolution with the current designed geometry. And the calorimeter is competent for the future External Target Facility (ETF) experiments.展开更多
基金supported by the National Natural Science Foundation of China(Nos.11805294 and 11975021)the China Postdoctoral Science Foundation(2018M631013),the Strategic Priority Research Program of Chinese Academy of Sciences(XDA10010900)+1 种基金the Fundamental Research Funds for the Central Universities,Sun Yatsen University(19lgpy268)in part by the CAS Center for Excellence in Particle Physics(CCEPP).
文摘Large-volume liquid scintillator detectors with ultra-low background levels have been widely used to study neutrino physics and search for dark matter.Event vertex and event time are not only useful for event selection but also essential for the reconstruction of event energy.In this study,four event vertex and event time reconstruction algorithms using charge and time information collected by photomultiplier tubes were analyzed comprehensively.The effects of photomultiplier tube properties were also investigated.The results indicate that the transit time spread is the main effect degrading the vertex reconstruction,while the effect of dark noise is limited.In addition,when the event is close to the detector boundary,the charge information provides better performance for vertex reconstruction than the time information.
基金This research was supported by the National Natural Science Foundation of China,Grant No.11775251the strategic leading science and technology program of Chinese Academy of Sciences(Grant No.XDA 15360100,XDA 15360102).
文摘Background Each GECAM satellite payload contains 25 gamma-ray detectors(GRDs),which can detect gamma-rays and particles and can roughly localize the Gamma-Ray Bursts(GRBs).GRD was designed using lanthanum bromide(LaBr3)crystal as the sensitive material with the rear end coupled with silicon photomultiplier(SiPM)array for readout.Purpose In aerospace engineering design of GRD,there are many key points to be studied.In this paper,we present the specific design scheme of GRD,the assembly and the performance test results of detectors.Methods Based on Monte Carlo simulation and experimental test results,the specific schematic design and assembling process of GRD were optimized.After being fully assembled,the GRDs were conducted performance tests by using radioactive source and also conducted random vibration tests.Result and conclusion The test results show that all satellite-borne GRDs have energy resolution<16%at 59.5 keV,meeting requirements of satellite in scientific performance.The random vibration test shows that GRD can maintain in a stable performance,which meets the requirement of spatial application.
基金Supported by Knowledge Innovation Project of Chinese Academy of Sciences (KJCX2-YW-N44,KJCX1-YW-004)State Key Development Program of Basic Research of China (2008CB817702)+1 种基金National Natural Science Foundation of China (10635080)National Natural Science Funds for Distinguished Young Scholars (10925526)
文摘A high detection efficiency calorimeter which is used to detect γ-rays with energies from 1 MeV up to 10 MeV as well as light charged particles has been proposed. Design of the geometry, results of the crystal tests and Monte Carlo simulations are presented in this paper. The simulation results confirm that the calorimeter can obtain high detection efficiency and good energy resolution with the current designed geometry. And the calorimeter is competent for the future External Target Facility (ETF) experiments.